Design and Optimization of Microwave Sensor for the Non-Contact Measurement of Pure Dielectric Materials

被引:14
|
作者
Ali, Luqman [1 ]
Wang, Cong [1 ]
Ullah, Inam [2 ]
Yousaf, Adnan [3 ]
Khan, Wali Ullah [4 ]
Ullah, Shafi [1 ]
Khan, Rahim [1 ]
Alassery, Fawaz [5 ]
Hamam, Habib [6 ]
Shafiq, Muhammad [7 ]
机构
[1] Harbin Inst Technol, Sch Informat & Commun, Harbin 150090, Peoples R China
[2] Hohai Univ, Coll Internet Things IoT Engn, Changzhou Campus, Nanjing 213022, Peoples R China
[3] Super Univ, Dept Elect Engn, Lahore 54000, Pakistan
[4] Univ Luxembourg, Interdisciplinary Ctr Secur Reliabil & Trust SnT, L-4365 Luxembourg, Luxembourg
[5] Taif Univ, Coll Comp & Informat Technol, Dept Comp Engn, At Taif 21974, Saudi Arabia
[6] Moncton Univ, Fac Engn, Moncton, NB E1A 3E9, Canada
[7] Yeungnam Univ, Dept Informat & Commun Engn, Gyongsan 38541, South Korea
关键词
air gap; electric field; microwave sensor; non-contact; optimized; SPLIT-RING-RESONATOR; METAMATERIAL-INSPIRED SENSOR; PERMITTIVITY;
D O I
10.3390/electronics10243057
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents an optimized microwave sensor for the non-contact measurement of complex permittivity and material thickness. The layout of the proposed sensor comprises the parallel combination of an interdigital capacitor (IDC) loaded at the center of the symmetrical differential bridge-type inductor fabricated on an RF-35 substrate (epsilon(r) = 3.5 and tan delta = 0.0018). The bridge-type differential inductor is introduced to obtain a maximum inductance value with high quality (Q) factor and low tunable resonant frequency. The central IDC structure is configured as a spur-line structure to create a high-intensity coupled electric field (e-field) zone, which significantly interacts with the materials under test (MUTs), resulting in an increased sensitivity. The proposed sensor prototype with optimized parameters generates a resonant frequency at 1.38 GHz for measuring the complex permittivity and material thickness. The experimental results indicated that the resonant frequency of the designed sensor revealed high sensitivities of 41 MHz/mm for thickness with a linear response (r(2) = 0.91567), and 53 MHz/Delta epsilon(r) for permittivity with a linear response (r(2) = 0.98903). The maximum error ratio for measuring MUTs with a high gap of 0.3 mm between the testing sample and resonator is 6.52%. The presented performance of the proposed sensor authenticates its application in the non-contact measurement of samples based on complex permittivity and thickness.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Dielectric measurement using non-contact microwave single probe for dielectric materials
    Kakemoto, Hirofumi
    Nam, Song-Min
    Wada, Satoshi
    Tsurumi, Takaaki
    JOURNAL OF ELECTROCERAMICS, 2006, 16 (04) : 561 - 564
  • [2] Dielectric measurement using non-contact microwave single probe for dielectric materials
    Hirofumi Kakemoto
    Song-Min Nam
    Satoshi Wada
    Takaaki Tsurumi
    Journal of Electroceramics, 2006, 16 : 561 - 564
  • [3] Non-contact active microwave sensor for glucose concentration measurement
    Suwanna, K.
    Harnsoongnoen, S.
    SIAM PHYSICS CONGRESS 2019 (SPC2019): PHYSICS BEYOND DISRUPTION SOCIETY, 2019, 1380
  • [4] High-frequency dielectric measurement using non-contact probe for dielectric materials
    Kakemoto, Hirofumi
    Nam, Song-Min
    Wada, Satoshi
    Tsurumi, Takaaki
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (4B): : 3002 - 3006
  • [5] Local permittivity measurement of dielectric materials based on the non-contact force curve of microwave atomic force microscopy
    Tong, Bo
    Zhao, Minji
    Toku, Yuhki
    Morita, Yasuyuki
    Ju, Yang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (03):
  • [6] Design of Non-contact measurement System
    Peng, Feng
    Wang, Zhuoer
    Peng, Bin
    Zheng, Liping
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 990 - 993
  • [7] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [8] Non-Contact Detection of Breathing Using a Microwave Sensor
    Dei, Devis
    Grazzini, Gilberto
    Luzi, Guido
    Pieraccini, Massimiliano
    Atzeni, Carlo
    Boncinelli, Sergio
    Camiciottoli, Gianna
    Castellani, Walter
    Marsili, Massimo
    Lo Dico, Juri
    SENSORS, 2009, 9 (04) : 2574 - 2585
  • [9] Spatial resolution for dielectric measurement using non-contact microwave probe and in-plane dielectric mappings for dielectric device
    Kakemoto, Hirofumi
    Li, Jianyong
    Harigai, Takakiyo
    Nam, Song-Min
    Wada, Satoshi
    Tsurumi, Takaaki
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (9B): : 7503 - 7507
  • [10] Non-contact method for measurement of the microwave conductivity of graphene
    Hao, L.
    Gallop, J.
    Goniszewski, S.
    Shaforost, O.
    Klein, N.
    Yakimova, R.
    APPLIED PHYSICS LETTERS, 2013, 103 (12)