Design and Optimization of Microwave Sensor for the Non-Contact Measurement of Pure Dielectric Materials

被引:14
|
作者
Ali, Luqman [1 ]
Wang, Cong [1 ]
Ullah, Inam [2 ]
Yousaf, Adnan [3 ]
Khan, Wali Ullah [4 ]
Ullah, Shafi [1 ]
Khan, Rahim [1 ]
Alassery, Fawaz [5 ]
Hamam, Habib [6 ]
Shafiq, Muhammad [7 ]
机构
[1] Harbin Inst Technol, Sch Informat & Commun, Harbin 150090, Peoples R China
[2] Hohai Univ, Coll Internet Things IoT Engn, Changzhou Campus, Nanjing 213022, Peoples R China
[3] Super Univ, Dept Elect Engn, Lahore 54000, Pakistan
[4] Univ Luxembourg, Interdisciplinary Ctr Secur Reliabil & Trust SnT, L-4365 Luxembourg, Luxembourg
[5] Taif Univ, Coll Comp & Informat Technol, Dept Comp Engn, At Taif 21974, Saudi Arabia
[6] Moncton Univ, Fac Engn, Moncton, NB E1A 3E9, Canada
[7] Yeungnam Univ, Dept Informat & Commun Engn, Gyongsan 38541, South Korea
关键词
air gap; electric field; microwave sensor; non-contact; optimized; SPLIT-RING-RESONATOR; METAMATERIAL-INSPIRED SENSOR; PERMITTIVITY;
D O I
10.3390/electronics10243057
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents an optimized microwave sensor for the non-contact measurement of complex permittivity and material thickness. The layout of the proposed sensor comprises the parallel combination of an interdigital capacitor (IDC) loaded at the center of the symmetrical differential bridge-type inductor fabricated on an RF-35 substrate (epsilon(r) = 3.5 and tan delta = 0.0018). The bridge-type differential inductor is introduced to obtain a maximum inductance value with high quality (Q) factor and low tunable resonant frequency. The central IDC structure is configured as a spur-line structure to create a high-intensity coupled electric field (e-field) zone, which significantly interacts with the materials under test (MUTs), resulting in an increased sensitivity. The proposed sensor prototype with optimized parameters generates a resonant frequency at 1.38 GHz for measuring the complex permittivity and material thickness. The experimental results indicated that the resonant frequency of the designed sensor revealed high sensitivities of 41 MHz/mm for thickness with a linear response (r(2) = 0.91567), and 53 MHz/Delta epsilon(r) for permittivity with a linear response (r(2) = 0.98903). The maximum error ratio for measuring MUTs with a high gap of 0.3 mm between the testing sample and resonator is 6.52%. The presented performance of the proposed sensor authenticates its application in the non-contact measurement of samples based on complex permittivity and thickness.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Non-contact high resolution microwave scanning measurement technology
    Berger, N
    Giraudon, JC
    Sulzbach, I
    Kantor, R
    Shvets, IV
    Landstorfer, FM
    ELECTRONICS LETTERS, 2003, 39 (14) : 1047 - 1048
  • [22] Reflection intensity measurement using non-contact microwave probe and in-plane mappings for dielectric device
    Kakemoto, Hirofumi
    Li, Jianyong
    Harigai, Takakiyo
    Nam, Song-Min
    Wada, Satoshi
    Tsurumi, Takaaki
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2007, 27 (8-9) : 2917 - 2921
  • [23] The Design and Implementation of a Non-contact Laser Measurement System
    ZHANG Ni ZHANG Yunwen LIU Weijun PU Xiongying China Agricultural University BeijingShenyang Institute of Automation Chinese Academy of SciencesShenyangChina
    微计算机信息, 2008, (22) : 7 - 9+162
  • [24] Terahertz Sensor for Non-contact Thickness Measurement of Car Paints
    Su, Ke
    May, Robert K.
    Gregory, Ian S.
    Taday, Philip F.
    Shen, Y. C.
    Zeitler, J. Axel
    2013 38TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2013,
  • [25] Non-contact Viscosity Measurement using Sensor Fusion Techniques
    Santhosh, K., V
    Prajwal, Kovoor
    2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING, INSTRUMENTATION AND CONTROL TECHNOLOGIES (ICICICT), 2017, : 677 - 680
  • [26] Non-Contact Body Measurement for Qinchuan Cattle with LiDAR Sensor
    Huang, Lvwen
    Li, Shuqin
    Zhu, Anqi
    Fan, Xinyun
    Zhang, Chenyang
    Wang, Hongyan
    SENSORS, 2018, 18 (09)
  • [27] Sleep/wake measurement using a non-contact biomotion sensor
    de Chazal, Philip
    Fox, Niall
    O'Hare, Emer
    Heneghan, Conor
    Zaffaroni, Alberto
    Boyle, Patricia
    Smith, Stephanie
    O'Connell, Caroline
    McNicholas, Walter T.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 (02) : 356 - 366
  • [28] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [29] Microwave-actuated robot sensor for non-contact solution detection
    Ma, Jin-Qiang
    Liang, Jun-Ge
    Wu, Jia-Kang
    Song, Yi-Ran
    Wu, En-Kang
    Qiang, Tian
    Gu, Xiao-Feng
    Wang, Cong
    Wang, Lei
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 379
  • [30] Non-Contact Biometric Identification and Authentication using Microwave Doppler Sensor
    Okano, Takaaki
    Izumi, Shintaro
    Kawaguchi, Hiroshi
    Yoshimoto, Masahiko
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,