High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE)

被引:0
|
作者
Walter, C
Philippi, G
Westerhausen, R
Kooijman, H
Hoffmann, HG
Busch, HP
机构
[1] Krankenhaus Barmherzigen Bruder, Abt Radiol, Trier, Germany
[2] Univ Trier, Zentrum Neuropsychol Forsch, D-54286 Trier, Germany
[3] Philips Med Syst, MR Clin Sci GMH05, Hamburg, Germany
关键词
MR-angiography; renal arteries; parallel imaging; spatial resolution; randomly segmented central k-space ordering;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare three dimensional contrast enhanced MR angiography with parallel imaging technique (sensitivity encoding) to standard MR angiography technique. Material and Methods: CE-3D MRA of renal arteries was performed in 22 patients (23 examinations) on a 1.5 T MR- scanner (Gyroscan Intera, Philips, Netherlands). For contrast enhanced MRA a single dose of Gd-DTPA (0.1 mmol/kg b.w.) was administered. Group 1: The following standard 3D gradient echo (GE) sequence was performed in 9 of the 22 patients: TR: 4.3 ms, TE: 1.5 ms, flip,angle: 40, 40 slices, scan duration: 19 seconds. A spatial resolution of 1.96 x 1.76 x 3.0 mm(3) (1.76 x 1.76 x 1.5 mm(3) interpolated) was obtained. Group 11: 14 examinations were acquired in 13 patients: TR, TE and flip angle were equal compared to the first protocol. The k-space lines were acquired with CENTRA (contrast-enhanced time robust angiography) and parallel-imaging technique (SENSE). 60 slices were acquired, scan duration was 24 seconds. The spatial resolution of this sequence was 1.19 x 1.08 x 2.0 mm(3) (0,84 x 0,84 x 1,0 mm(3) interpolated). Original images and calculated maximum intensity projection (MIP) images were analysed by two radiologists. Image quality and the visibility of renal arteries were rated on a four-point scale. Results: In the first group the image quality was rated "good" in 8/9 patients. The renal arteries were detected in all cases and rated "good". The anterior and posterior segments were rated,,good" in only 5/9 and the lobar arteries were detectable only in 3 of 9 cases. The interlobar arteries could not be seen in these patients. In the second group the image quality was rated excellent in 5 examinations and good in 9 of 14 examinations. The rating for the renal arteries was excellent in all examinations (14/14). The results of the anterior and posterior segment were as followed: excellent 5/14, good 7/14, insufficient 2/14; the lobar arteries: good 6/14, insufficient 6/14 and not detectable 2/14. Interlobar arteries could be seen in 7/14 examinations, but the quality was insufficient. In 7/ 14 the interlobar arteries could not be detected. Conclusion: The use of parallel imaging technique improves image quality and the delineation of small vessels in renal MRA.
引用
收藏
页码:1244 / 1250
页数:7
相关论文
共 50 条
  • [31] Applications of 3D contrast-enhanced MR angiography in pediatric oncology
    Haliloglu, M
    Hoffer, FA
    Gronemeyer, SA
    Rao, BN
    PEDIATRIC RADIOLOGY, 1999, 29 (11) : 863 - 868
  • [32] Contrast-enhanced MR 3D angiography in the assessment of brain AVMs
    Unlu, Ercument
    Temizoz, Osman
    Albayram, Sait
    Genchellac, Hakan
    Hamamcioglu, M. Kemal
    Kurt, Imran
    Demir, M. Kemal
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 367 - 378
  • [33] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [34] Visceral artery aneurysms: Evaluation using 3D contrast-enhanced MR angiography
    Liu, Qi
    Lu, Jian Ping
    Wang, Fei
    Wang, Li
    Jin, Ai Guo
    Wang, Jian
    Tian, Jian Ming
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (03) : 826 - 833
  • [35] VENOUS ANGIOMAS - PLAIN AND CONTRAST-ENHANCED MRI AND MR-ANGIOGRAPHY
    CRECCO, M
    FLORIS, R
    VIDIRI, A
    SQUILLACI, E
    SERGIACOMI, GL
    MATTIOLI, M
    SIMONETTI, G
    SQUILLACI, S
    NEURORADIOLOGY, 1995, 37 (01) : 20 - 24
  • [36] BREATH-HOLD 3D STAR MR-ANGIOGRAPHY OF THE RENAL-ARTERIES USING SEGMENTED ECHO-PLANAR IMAGING
    WIELOPOLSKI, PA
    ADAMIS, M
    PRASAD, P
    GAA, J
    EDELMAN, R
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) : 432 - 438
  • [37] Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA
    Krishnam, M. S.
    Tomasian, A.
    Lohan, D. G.
    Tran, L.
    Finn, J. P.
    Ruehm, S. G.
    CLINICAL RADIOLOGY, 2008, 63 (07) : 744 - 755
  • [38] Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging
    Tsuchiya, K
    Honya, K
    Fujikawa, A
    Tateishi, H
    Shiokawa, Y
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (09) : 2243 - 2247
  • [39] Time-resolved Contrast-enhanced 3D MR Angiography Using Parallel Imaging with View Sharing (TREAT) - comparing with Breath-hold Single Phase High Spatial 3D Contrast Magnetic Resonance Angiography
    Lu, M.
    Zhao, S.
    Jiang, S.
    Zhang, Y.
    CARDIOLOGY, 2009, 114 : 98 - 99
  • [40] Contrast-enhanced 3D MR breathhold imaging of porcine coronary arteries using fluoroscopic localization and bolus triggering
    Kruger, DG
    Busse, RF
    Johnston, DL
    Ritman, EL
    Ehman, RL
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1159 - 1165