Contrast-enhanced MR 3D angiography in the assessment of brain AVMs

被引:44
|
作者
Unlu, Ercument
Temizoz, Osman
Albayram, Sait
Genchellac, Hakan
Hamamcioglu, M. Kemal
Kurt, Imran
Demir, M. Kemal
机构
[1] Trakya Univ, Sch Med, Dept Radiol, Edirne, Turkey
[2] Istanbul Univ, Cerrahpasa Med Sch, Dept Radiol, Istanbul, Turkey
[3] Trakya Univ, Sch Med, Dept Neurosurg, Edirne, Turkey
[4] Trakya Univ, Sch Med, Dept Biostat, Edirne, Turkey
关键词
contrast-enhanced magnetic resonance angiography; time-of-flight magnetic resonance angiography; conventional catheter angiography; arteriovenous malformation; brain;
D O I
10.1016/j.ejrad.2006.08.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: Digital subtraction angiography (DSA) is the current reference standard for the diagnosis, assessment, and management of brain arteriovenous malformations (AVMs). The purpose of this study was to compare the diagnostic utility of three-dimensional (3D) time-off-light (TOF) magnetic resonance angiography (MRA) and contrast-enhanced 3D MRA in patients with intracranial arteriovenous malformations (AVMs) in different sizes and locations. The AVM diagnosis was proved via DSA and almost half of the patients had also hematoma. Materials and methods: Two radiologists, experienced on neurovascular imaging and independent from each other, retrospectively reviewed two MRA techniques and DSA with regard to the assessment of feeding arteries, AVM nidus, and venous drainage patterns on 20 patients with 23 examinations by scoring system. Disagreements were resolved by consensus. Results: An excellent agreement between contrast-enhanced MRA and DSA was found in order to assess the numbers of arterial feeders and draining veins (Spearman r=0.913, P<0.001). The average scores in contrast-enhanced MRA for feeders, nidi, and drainers were respectively 2.26, 2.69, and 2.48, while in TOF-MRA they are 1.96, 1.35, and 0.89, respectively. Conclusion: Compared to TOF-MRA, 3D contrast-enhanced MRA is useful for visualization by subtraction technique of malformation components presented by hematoma or by haem product. On the other hand, for the cases presented by slow or complex flow that is especially in around or nidi or around the venous portion is also advantageous because of the independence from flow-related enhancement. Therapeutic effects were clearly demonstrated in three follow-up patients. A major limitation of this technique is the low spatial resolution. Since there is such a limitation, arterial feeder of a case with micro-AVM is not detected by contrast-enhanced MRA and nidus for the same case was observed retrospectively. In this respect, we believe that 3D contrast-enhanced MRA is a less invasive and inexpensive angiographic tool, but not a safe substitute for DSA. Yet, it can be a beneficial supplement to DSA in patients with cerebral AVMs at both initial diagnosis and at follow-up processes after therapy. (C) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:367 / 378
页数:12
相关论文
共 50 条
  • [1] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [2] Cerebral arteriovenous malformations (AVMs): Morphologic evaluation by ultrashort 3D contrast-enhanced MR angiography
    Essig, M
    Schoenberg, SO
    Knopp, MV
    Debus, J
    Lohr, F
    VanKaick, G
    [J]. RADIOLOGY, 1997, 205 : 1136 - 1136
  • [3] Time-resolved, contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. RADIOLOGY, 1996, 201 : 1085 - 1085
  • [4] Applications of 3D contrast-enhanced MR angiography in pediatric oncology
    Haliloglu, M
    Hoffer, FA
    Gronemeyer, SA
    Rao, BN
    [J]. PEDIATRIC RADIOLOGY, 1999, 29 (11) : 863 - 868
  • [5] Value of contrast-enhanced 3D MR angiography of the renal arteries
    Hany, TF
    Pfammatter, T
    Schmidt, M
    Leung, DA
    Debatin, JF
    [J]. RADIOLOGE, 1997, 37 (07): : 547 - 553
  • [6] Value of contrast-enhanced 3D MR angiography of the renal arteries
    T. F. Hany
    T. Pfammatter
    Michaela Schmidt
    D. A. Leung
    J. F. Debatin
    [J]. Der Radiologe, 1997, 37 : 547 - 553
  • [7] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [8] 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain
    Haider, Clifton R.
    Hu, Houchun Harry
    Campeau, Norbert G.
    Huston, John, III
    Riederer, Stephen J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 749 - 760
  • [9] Contrast-enhanced 3D MR angiography in the chest, abdomen and lower extremities
    Rühm, SG
    Debatin, JF
    [J]. RADIOLOGE, 1999, 39 (02): : 100 - 109
  • [10] Head and neck paragangliomas: Value of contrast-enhanced 3D MR angiography
    Neves, F.
    Huwart, L.
    Jourdan, G.
    Reizine, D.
    Herman, P.
    Vicaut, E.
    Guichard, J. P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) : 883 - 889