Mass-Preserving Motion Correction of Dual Gated Cardiac PET

被引:0
|
作者
Gigengack, Fabian [1 ]
Ruthotto, Lars [2 ]
Burger, Martin [3 ]
Wolters, Carsten H. [4 ]
Jiang, Xiaoyi
Schaefers, Klaus P. [1 ,5 ]
机构
[1] Univ Munster, EIMI, Dept Math & Comp Sci, D-4400 Munster, Germany
[2] Univ Lubeck, Inst Math & Image Comp MIC, Lubeck, Germany
[3] Univ Munster, Inst Computat & Appl Math, Munster, Germany
[4] Univ Munster, Inst Biomagnetism & Biosignalanal, Munster, Germany
[5] Univ Munster, EIMI, Munster, Germany
关键词
motion correction; mass-preservation; image registration; dual gating; hyperelastic regularization; PET;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image degradation due to motion is a known problem in Positron Emission Tomography (PET). To reduce motion artifacts in PET, gating based techniques were found applicable. In pure respiratory gated PET, each gate still contains cardiac motion. Analogously, pure cardiac gated PET images still contain respiratory motion. Hence, we make use of dual (joint respiratory and cardiac) gating to further reduce the amount of motion contained in the images. The inclusion of non-rigid cardiac motion leads to intensity modulations caused by the Partial Volume Effect (PVE). To overcome the intensity modulations we identified and considered the mass-preserving property of PET images in the Variational Algorithm for Mass-Preserving Image REgistration (VAMPIRE). The aim of this paper is the elimination of both cardiac and respiratory motion in thoracic dual gated PET without a loss of statistic. The strategy of our proposed motion correction approach is: 1) Dual gating, 2) Mass-preserving motion estimation (VAMPIRE), and 3) Averaging of the aligned images. In a patient study we showed that the proposed mass-preserving motion correction strategy significantly removes motion artifacts in cardiac PET. VAMPIRE achieved accurate results that resemble cardiac and respiratory motion across all patients.
引用
收藏
页码:3206 / 3208
页数:3
相关论文
共 50 条
  • [31] Pilot study of the dual motion correction techniques using ECG gating and data-driven respiratory motion correction for cardiac PET
    Takanami, Kentaro
    Odagiri, Hayato
    Watabe, Hiroshi
    Kawakami, Hirofumi
    Katsuki, Akie
    Uetake, Nozomu
    Takase, Kei
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [32] Dual-gated cardiac PET–Clinical feasibility study
    Mika Teräs
    Tommi Kokki
    Nicolas Durand-Schaefer
    Tommi Noponen
    Mikko Pietilä
    Jan Kiss
    Erika Hoppela
    Hannu T. Sipilä
    Juhani Knuuti
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 505 - 516
  • [33] Elastic motion correction improves Rb-82 Cardiac PET ECG-gated image quality
    Wiefels, Christiane
    Chow, Benjamin
    Ruddy, Terrence
    Beanlands, Rob
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [34] Development of a motion correction system for respiratory-gated PET study
    Woo, SK
    Choi, JY
    Song, TY
    Choi, Y
    Lee, KH
    Kim, BT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2366 - 2369
  • [35] Alignment of dynamic cardiac PET images for correction of motion
    Turkington, TG
    DeGrado, TR
    Hanson, MW
    Coleman, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) : 235 - 242
  • [36] Data-driven motion correction for cardiac PET
    Armstrong, Ian
    Hayden, Charles
    Arumugam, Parthiban
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [37] A general, mass-preserving Navier-Stokes projection method
    Salac, David
    COMPUTER PHYSICS COMMUNICATIONS, 2016, 204 : 97 - 106
  • [38] Development of Motion Correction Methods for Cardiac PET Imaging
    Noponen, T.
    Klen, R.
    Kokki, T.
    Teuho, J.
    Thielemans, K.
    Koikkalainen, J.
    Hoppela, E.
    Sipila, H.
    Lotjonen, J.
    Teras, M.
    Knuuti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S72 - S72
  • [39] A DUAL ISOTOPE MOTION CORRECTION TECHNIQUE TO REDUCE MOTION BLUR IN GATED EXERCISE SCINTIGRAPHY
    GROCH, MW
    DOMNANOVICH, JR
    ERWIN, WD
    TURNER, DA
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P30 - P31
  • [40] Development and evaluation of two 4D image reconstruction methods with dual respiratory and cardiac motion compensation for gated cardiac PET
    Feng, Tao
    Ahlman, Mark A.
    Guo, Liheng
    Bluemke, David A.
    Tsui, Benjamin M. W.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,