Mass-Preserving Motion Correction of Dual Gated Cardiac PET

被引:0
|
作者
Gigengack, Fabian [1 ]
Ruthotto, Lars [2 ]
Burger, Martin [3 ]
Wolters, Carsten H. [4 ]
Jiang, Xiaoyi
Schaefers, Klaus P. [1 ,5 ]
机构
[1] Univ Munster, EIMI, Dept Math & Comp Sci, D-4400 Munster, Germany
[2] Univ Lubeck, Inst Math & Image Comp MIC, Lubeck, Germany
[3] Univ Munster, Inst Computat & Appl Math, Munster, Germany
[4] Univ Munster, Inst Biomagnetism & Biosignalanal, Munster, Germany
[5] Univ Munster, EIMI, Munster, Germany
关键词
motion correction; mass-preservation; image registration; dual gating; hyperelastic regularization; PET;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image degradation due to motion is a known problem in Positron Emission Tomography (PET). To reduce motion artifacts in PET, gating based techniques were found applicable. In pure respiratory gated PET, each gate still contains cardiac motion. Analogously, pure cardiac gated PET images still contain respiratory motion. Hence, we make use of dual (joint respiratory and cardiac) gating to further reduce the amount of motion contained in the images. The inclusion of non-rigid cardiac motion leads to intensity modulations caused by the Partial Volume Effect (PVE). To overcome the intensity modulations we identified and considered the mass-preserving property of PET images in the Variational Algorithm for Mass-Preserving Image REgistration (VAMPIRE). The aim of this paper is the elimination of both cardiac and respiratory motion in thoracic dual gated PET without a loss of statistic. The strategy of our proposed motion correction approach is: 1) Dual gating, 2) Mass-preserving motion estimation (VAMPIRE), and 3) Averaging of the aligned images. In a patient study we showed that the proposed mass-preserving motion correction strategy significantly removes motion artifacts in cardiac PET. VAMPIRE achieved accurate results that resemble cardiac and respiratory motion across all patients.
引用
收藏
页码:3206 / 3208
页数:3
相关论文
共 50 条
  • [21] Mass-Preserving Modeling of Diffusion in a Closed System
    Malakhov, Dmitri V.
    JOURNAL OF PHASE EQUILIBRIA AND DIFFUSION, 2025, 46 (01) : 31 - 48
  • [22] Pre-clinical evaluation of a respiratory motion correction technique in dual gated cardiac imaging
    Lamare, Frederic
    Rimoldi, Ornella
    Teras, Mika
    Kokki, Tommi
    Knuuti, Juhani
    Visvikis, Dimitris
    Camici, Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [23] Motion Correction in Respiratory Gated Cardiac PET/CT Using Multi-scale Optical Flow
    Dawood, Mohammad
    Koesters, Thomas
    Fieseler, Michael
    Buether, Florian
    Jiang, Xiaoyi
    Wuebbeling, Frank
    Schaefers, Klaus P.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 155 - 162
  • [24] Enhancing Cardiac PET by Motion Correction Techniques
    Mathieu Rubeaux
    Mhairi K. Doris
    Adam Alessio
    Piotr J. Slomka
    Current Cardiology Reports, 2017, 19
  • [25] Elastic Motion Correction for Cardiac PET Studies
    Hong, Inki
    Jones, Judson
    Casey, Michael
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] Enhancing Cardiac PET by Motion Correction Techniques
    Rubeaux, Mathieu
    Doris, Mhairi K.
    Alessio, Adam
    Slomka, Piotr J.
    CURRENT CARDIOLOGY REPORTS, 2017, 19 (02)
  • [27] A geometric mass-preserving redistancing scheme for the level set function
    Ausas, Roberto F.
    Dari, Enzo A.
    Buscaglia, Gustavo C.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2011, 65 (08) : 989 - 1010
  • [28] The smallest multistationary mass-preserving chemical reaction network
    Shiu, Anne
    ALGEBRAIC BIOLOGY, PROCEEDINGS, 2008, 5147 : 172 - 184
  • [29] Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR
    Kolbitsch, Christoph
    Ahlman, Mark A.
    Davies-Venn, Cynthia
    Evers, Robert
    Hansen, Michael
    Peressutti, Devis
    Marsden, Paul
    Kellman, Peter
    Bluemke, David A.
    Schaeffter, Tobias
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 846 - 852
  • [30] MRI Assisted Motion Correction in Dual-Gated 5D Myocardial Perfusion PET Imaging
    Tang, Jing
    Hall, Neal
    Rahmim, Arman