A biosensor based on catalase for determination of highly toxic chemical azide in fruit juices

被引:30
|
作者
Sezgintürk, MK [1 ]
Göktug, T [1 ]
Dinçkaya, E [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
来源
BIOSENSORS & BIOELECTRONICS | 2005年 / 21卷 / 04期
关键词
azide; biosensor; inhibitor biosensors; catalase;
D O I
10.1016/j.bios.2005.01.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, an amperometric biosensor based on catalase enzyme was developed for the determination of azide. The principle of the measurements was based on the determination of the decrease in the differentiation of oxygen level which had been caused by the inhibition of catalase in the bioactive layer of the biosensor by azide. Firstly, the optimum conditions for the inhibitor biosensor were established. In the optimization studies of the biosensor, the most suitable catalase and gelatin amounts and glutaraldehyde ratio were determined. Optimum catalase activity, optimum gelatin amount and glutaraldehyde percentage were 5000 U cm(-2), 5.94 mg cm(-2) and 2.5% respectively. Characterization studies of the biosensor such as optimum pH and optimum temperature were carried out. The repeatability experiments were done and the average value (x), standard deviation (S.D.) and variation coefficient (C.V.) were calculated as 98.6 mu M, +/- 4.16 mu M and 4.23%, respectively. A good linear relationship with a correlation coefficient of 0.9902 was obtained over the concentration range of 25 mu M to 300 mu M azide. After the optimization and characterization studies the proposed biosensor was applied to the determination of azide in certain fruit juices. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:684 / 688
页数:5
相关论文
共 50 条
  • [1] Investigation of a multienzyme based amperometric biosensor for determination of sucrose in fruit juices
    Krisztina Majer-Baranyi
    Nóra Adányi
    Mária Váradi
    European Food Research and Technology, 2008, 228 : 139 - 144
  • [2] Investigation of a multienzyme based amperometric biosensor for determination of sucrose in fruit juices
    Majer-Baranyi, Krisztina
    Adanyi, Nora
    Varadi, Maria
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 228 (01) : 139 - 144
  • [3] Polyaniline Based Catalase Biosensor for the Detection of Hydrogen Peroxide and Azide
    Singh, Ravindra P.
    Kang, Da-Yeon
    Oh, Byung-Keun
    Choi, Jeong-Woo
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2009, 14 (04) : 443 - 449
  • [4] Polyaniline based catalase biosensor for the detection of hydrogen peroxide and azide
    Ravindra P. Singh
    Da-Yeon Kang
    Byung-Keun Oh
    Jeong-Woo Choi
    Biotechnology and Bioprocess Engineering, 2009, 14 : 443 - 449
  • [5] Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis
    Yann Guémas
    Mohamed Boujtita
    Nabil El Murr
    Applied Biochemistry and Biotechnology, 2000, 89 : 171 - 181
  • [6] Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis
    Guémas, Y
    Boujtita, M
    El Murr, N
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 171 - 181
  • [7] A new PANI biosensor based on catalase for cyanide determination
    Ozcan, Hakki Mevlut
    Aydin, Tuba
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2016, 44 (02) : 664 - 671
  • [8] A new approach for nitrite determination based on a HRP/catalase biosensor
    Chen, Hao
    Mousty, Christine
    Chen, Ling
    Cosnier, Serge
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6): : 726 - 730
  • [9] Development of a catalase based biosensor for alcohol determination in beer samples
    Akyilmaz, E
    Dinçkaya, E
    TALANTA, 2003, 61 (02) : 113 - 118
  • [10] Development of a Catalase-Based Amperometric Biosensor for the Determination of Increased Catalase Content in Milk Samples
    Futo, Peter
    Markus, Gabriella
    Kiss, Attila
    Adanyi, Nora
    ELECTROANALYSIS, 2012, 24 (01) : 107 - 113