Natural gas compositions variation effect on capillary tube thermal mass flow meter performance

被引:20
|
作者
Parvizi, S. [1 ]
Arabkoohsar, A. [2 ]
Farzaneh-Gord, M. [1 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[2] Islamic Azad Univ, Azadshahr Branch, Dept Mech Engn, Azadshahr, Iran
关键词
Capillary tube thermal flow meter; Natural gas; Compositions variation; Error analysis; FLOWMETER; SENSOR;
D O I
10.1016/j.flowmeasinst.2016.07.007
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Thermal mass flow meters are broadly used in different parts of industry for flow metering objectives from very low up to very high flow rates. One of the most widely used thermal flow meters is capillary tube type which is more appropriate for measuring low mass flow rates. On the other hand, natural gas measurement accuracy in residential use has already been studied by the authors and it was found out that considerable amount of natural gas is lost over the year due to inaccurate flow metering. In order to resolve this problem, employing capillary tube mass flow meters instead of conventional counters in houses, assuming natural gas as pure methane, was proposed and investigated, resulting to satisfactory outcomes. Although pure methane well estimates natural gas behavior in many cases, it may not be an accurate assumption for heavy natural gas mixtures composed of lower methane fractions. Therefore, in this work, the effect of natural gas compositions variation on the performance of capillary tube thermal mass flow meters in residential use is studied. For this objective, various natural gas fields of Iran are considered and differential equations of natural gas stream and sensor tube are solved contemporary in Matlab. In the end, in order to validate the simulation approach and conditions, the simulation was accomplished for Nitrogen, for which experimental data was available in the literature. The results show that using an average specific heat capacity value for different mixtures causes a deviation below a maximum of only 1.8% and overall average error of 0.62% in measurement accuracy. It was also found out that changes in other properties of natural gas does not affect the accuracy. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [31] Two-phase flow in a gas-injected capillary tube
    Park, CS
    Baek, SY
    Lee, KJ
    Kim, SW
    ADVANCES IN POLYMER TECHNOLOGY, 2003, 22 (04) : 320 - 328
  • [32] Development of a thermal mass flow meter for heavy liquid metal applications
    Puviani, P. Cioli
    Venturini, A.
    Di Piazza, I.
    Sermenghi, V.
    Del Moro, T.
    Papa, F.
    Martelli, D.
    Zanino, R.
    Tarantino, M.
    NUCLEAR ENGINEERING AND DESIGN, 2024, 427
  • [34] MEMS Thermal Mass Flow Meter with Double-Heater Structure
    Wu, Yuan-Qing
    Yao, Su-Ying
    2011 INTERNATIONAL CONFERENCE OF ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2011,
  • [35] A thermal-calorimetric gas flow meter with improved isolating feature
    Yaghmourali, Yousef Valizadeh
    Ahmadi, Nima
    Abbaspour-sani, Ebrahim
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (06): : 1927 - 1936
  • [36] A thermal-calorimetric gas flow meter with improved isolating feature
    Yousef Valizadeh Yaghmourali
    Nima Ahmadi
    Ebrahim Abbaspour-sani
    Microsystem Technologies, 2017, 23 : 1927 - 1936
  • [37] CALCULATION OF THE MASS AND THERMAL FLOW IN THE GAS FLAME
    KOMORNICKI, W
    CHEMISCHE TECHNIK, 1983, 35 (05): : 269 - 269
  • [38] INVESTIGATION OF NATURAL GAS THERMAL SEPARATION THROUGH A VORTEX TUBE
    Farzaneh-Gord, Mahmood
    Kargaran, Mahyar
    Bayat, Yoones
    Hashemi, Shahram
    JOURNAL OF ENHANCED HEAT TRANSFER, 2012, 19 (01) : 87 - 94
  • [39] Effect of flow orientation on liquid-liquid slug flow in a capillary tube
    Biswas, Koushik Guha
    Patra, Rahul
    Das, Gargi
    Ray, Subhabrata
    Basu, Jayanta Kumar
    CHEMICAL ENGINEERING JOURNAL, 2015, 262 : 436 - 446
  • [40] FLOW MEASUREMENT WITH DIAPHRAGM AND SUBSEQUENT INTEGRATORS IN NATURAL GAS PIPELINES (EFFECTIVE HEAD GAS METER)
    KONRAD, WJ
    MESSTECHNIK, 1968, 76 (08): : 202 - &