Natural gas compositions variation effect on capillary tube thermal mass flow meter performance

被引:20
|
作者
Parvizi, S. [1 ]
Arabkoohsar, A. [2 ]
Farzaneh-Gord, M. [1 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[2] Islamic Azad Univ, Azadshahr Branch, Dept Mech Engn, Azadshahr, Iran
关键词
Capillary tube thermal flow meter; Natural gas; Compositions variation; Error analysis; FLOWMETER; SENSOR;
D O I
10.1016/j.flowmeasinst.2016.07.007
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Thermal mass flow meters are broadly used in different parts of industry for flow metering objectives from very low up to very high flow rates. One of the most widely used thermal flow meters is capillary tube type which is more appropriate for measuring low mass flow rates. On the other hand, natural gas measurement accuracy in residential use has already been studied by the authors and it was found out that considerable amount of natural gas is lost over the year due to inaccurate flow metering. In order to resolve this problem, employing capillary tube mass flow meters instead of conventional counters in houses, assuming natural gas as pure methane, was proposed and investigated, resulting to satisfactory outcomes. Although pure methane well estimates natural gas behavior in many cases, it may not be an accurate assumption for heavy natural gas mixtures composed of lower methane fractions. Therefore, in this work, the effect of natural gas compositions variation on the performance of capillary tube thermal mass flow meters in residential use is studied. For this objective, various natural gas fields of Iran are considered and differential equations of natural gas stream and sensor tube are solved contemporary in Matlab. In the end, in order to validate the simulation approach and conditions, the simulation was accomplished for Nitrogen, for which experimental data was available in the literature. The results show that using an average specific heat capacity value for different mixtures causes a deviation below a maximum of only 1.8% and overall average error of 0.62% in measurement accuracy. It was also found out that changes in other properties of natural gas does not affect the accuracy. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [21] MODEL FOR THE DEVELOPMENT OF A LOW COST THERMAL MASS FLOW METER
    Garcia-Arellano, C.
    Garcia-Valladares, O.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2012, 11 (01): : 177 - 192
  • [22] THERMAL MASS-FLOW METER FOR CORROSIVE-GASES
    WIEGLEB, G
    TECHNISCHES MESSEN, 1984, 51 (02): : 43 - 45
  • [23] MEASUREMENT AND REGULATION OF GAS MICROFLOW FROM A THERMAL FLOW METER
    AYME, P
    COULOMB, M
    SAUZEAU, M
    MESURES REGULATION AUTOMATISME, 1970, 35 (8-9): : 73 - &
  • [24] Development of Gas Meter based on MEMS Thermal Flow Sensor
    Wu, Chenguang
    Liu, Genli
    Zhai, Yuan
    Xiang, Yi
    Bai, Junjie
    Shi, Jinliang
    Wu, Ying
    Zheng, Fuzhong
    2019 14TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE-NEMS 2019), 2019, : 192 - 195
  • [26] EFFECT OF ALTITUDE ON PEAK FLOW METER PERFORMANCE
    JENSEN, RL
    CRAPO, RO
    BERLIN, SL
    CLINICAL RESEARCH, 1992, 40 (01): : A125 - A125
  • [27] The Effect of the Absorbed Fluid Layer on Flow in a Capillary Tube
    Li, Y.
    Yao, J.
    Yang, Y.
    PETROLEUM SCIENCE AND TECHNOLOGY, 2014, 32 (02) : 194 - 201
  • [28] Mass Transfer Across Gas-Liquid Interface in a Capillary Tube
    Ito, Yasumasa
    Komori, Satoru
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2008, 41 (10) : 947 - 952
  • [29] Evaluation of hydrogen concentration effect on the natural gas properties and flow performance
    Abd, Ammar Ali
    Naji, Samah Zaki
    Thian, Tye Ching
    Othman, Mohd Roslee
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (01) : 974 - 983
  • [30] Thermal instability in laminar flow of heated gas in a tube
    Kung Cheng Je Wu Li Hsueh Pao, 6 (736-739):