Effect of Change of Position (Supine vs. Steep Trendelenburg) on Bispectral Index Value During Robotic Surgery

被引:0
|
作者
Kumar, Sachin [1 ]
Balyan, Rohit [2 ]
Nair, Arjun [2 ]
Tope, Rajesh [3 ]
Kumar, Vijay [3 ]
Shrivastava, Tulika [3 ]
Anshul [4 ]
Kalia, Rajni [5 ]
Kaur, Jasleen [6 ]
机构
[1] All India Inst Med Sci, Anesthesiol, New Delhi, India
[2] Maulana Azad Med Coll, Anaesthesiol, Delhi, India
[3] Indraprastha Apollo Hosp, Anaesthesiol, Delhi, ON, India
[4] Pandit Bhagwat Dayal Sharma Post Grad Inst Med Sci, Anaesthesiol, Rohtak, India
[5] Govt Med Coll & Hosp, Anaesthesiol, Chandigarh, India
[6] Maharishi Markandeshwar Univ MMU Kumarhatti Solan, Anaesthesiol, Solan, India
关键词
bis; robotic hysterectomies; robotic prostatectomies; robotic surgery; depth of anaesthesia; steep trendelenburg; bispectral index; BRAIN;
D O I
10.7759/cureus.29180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Bispectral Index (BIS) is used to monitor anesthetic depth and is a useful instrument to keep a check on intraoperative awareness. But there are various situations in which it shows false readings. Our aim of the study was to observe the changes in BIS value with steep Trendelenburg position, which is usually done, in robotic pelvic surgeries.Methods: We included 100 patients in our study who underwent robotic prostatectomies and hysterectomies. After anesthetizing the patient, the patient's heart rate, systolic blood pressure, mean arterial pressure, end -tidal desflurane, end-tidal CO2, and BIS were recorded at three min. intervals, for 15 minutes before and 15 minutes after the Trendelenburg position without surgical stimulus. Results: We found a significant increase in BIS values (p <0.05) after the change of position from supine to steep Trendelenburg. Heart rate, systolic blood pressure, and mean arterial pressure were almost constant.Conclusion: Our study concluded that the BIS value increases when patients were shifted from the supine to Trendelenburg position, which might raise the concern of a decrease in anesthetic depth.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] APEX TO BASE DEPOSITION OF RADIOAEROSOLS IN CF LUNGS: EFFECT OF INHALATION IN SUPINE VS. SITTING POSITION
    Bennett, William
    Zeman, Kirby
    Wu, Jihong
    Duckworth, Heather
    Salazar, Claudia
    Donaldson, Scott
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : A37 - A37
  • [42] What is the best patient's position during ERCP? A prospective randomized trial comparing prone vs. supine position
    Terruzzi, V
    Radaelli, F
    Meucci, G
    Minoli, G
    GASTROINTESTINAL ENDOSCOPY, 2004, 59 (05) : AB193 - AB193
  • [43] Extremely low bispectral index value during robotic-assisted laparoscopic prostatectomy: A case report
    Hoshi, Takuo
    SAUDI JOURNAL OF ANAESTHESIA, 2022, 16 (02) : 214 - 216
  • [44] The effect of intravenous lidocaine infusion on bispectral index during major abdominal surgery
    Patrick Bazin
    James Padley
    Matthew Ho
    Jennifer Stevens
    Erez Ben-Menachem
    Journal of Clinical Monitoring and Computing, 2018, 32 : 533 - 539
  • [45] The effect of intravenous lidocaine infusion on bispectral index during major abdominal surgery
    Bazin, Patrick
    Padley, James
    Ho, Matthew
    Stevens, Jennifer
    Ben-Menachem, Erez
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (03) : 533 - 539
  • [46] Effect of Sitting Position vs. Supine Position With the Head Turned to the Affected Side on Benign Paroxysmal Positional Vertigo Fatigue
    Imai, Takao
    Nishiike, Suetaka
    Okumura, Tomoko
    Takeda, Noriaki
    Sato, Takashi
    Ohta, Yumi
    Kamakura, Takefumi
    Inohara, Hidenori
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [47] Change in endotracheal cuff pressure in different cuff shapes during gynaecological laparoscopic surgery in the Trendelenburg position
    Techapiyaporn, S.
    Karnjanawanichkul, O.
    Chanchayanon, T.
    Juthasantikul, W.
    Suwanrat, B.
    ANAESTHESIA, 2018, 73 : 43 - 43
  • [48] Assessing the predictive value of the bispectral index vs patient state index on clinical assessment of sedation in postoperative cardiac surgery patients
    Adesanya, Adebota O.
    Rosero, Eric
    Wyrick, Christine
    Wall, Michael H.
    Joshi, Girish P.
    JOURNAL OF CRITICAL CARE, 2009, 24 (03) : 322 - 328
  • [49] Effect of pneumoperitoneum and Trendelenburg position on internal carotid artery blood flow measured by ultrasound during robotic prostatectomy
    Yu, Jihion
    Park, Jun-Young
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (02) : 139 - 145
  • [50] Optic nerve sheath diameter-guided extubation plan in obese patients undergoing robotic pelvic surgery in steep Trendelenburg position: A report of three cases
    Sujata, Nambiath
    Tobin, Raj
    Mehta, Punit
    Girotra, Gautam
    INDIAN JOURNAL OF ANAESTHESIA, 2018, 62 (11) : 896 - 899