Effect of Change of Position (Supine vs. Steep Trendelenburg) on Bispectral Index Value During Robotic Surgery

被引:0
|
作者
Kumar, Sachin [1 ]
Balyan, Rohit [2 ]
Nair, Arjun [2 ]
Tope, Rajesh [3 ]
Kumar, Vijay [3 ]
Shrivastava, Tulika [3 ]
Anshul [4 ]
Kalia, Rajni [5 ]
Kaur, Jasleen [6 ]
机构
[1] All India Inst Med Sci, Anesthesiol, New Delhi, India
[2] Maulana Azad Med Coll, Anaesthesiol, Delhi, India
[3] Indraprastha Apollo Hosp, Anaesthesiol, Delhi, ON, India
[4] Pandit Bhagwat Dayal Sharma Post Grad Inst Med Sci, Anaesthesiol, Rohtak, India
[5] Govt Med Coll & Hosp, Anaesthesiol, Chandigarh, India
[6] Maharishi Markandeshwar Univ MMU Kumarhatti Solan, Anaesthesiol, Solan, India
关键词
bis; robotic hysterectomies; robotic prostatectomies; robotic surgery; depth of anaesthesia; steep trendelenburg; bispectral index; BRAIN;
D O I
10.7759/cureus.29180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Bispectral Index (BIS) is used to monitor anesthetic depth and is a useful instrument to keep a check on intraoperative awareness. But there are various situations in which it shows false readings. Our aim of the study was to observe the changes in BIS value with steep Trendelenburg position, which is usually done, in robotic pelvic surgeries.Methods: We included 100 patients in our study who underwent robotic prostatectomies and hysterectomies. After anesthetizing the patient, the patient's heart rate, systolic blood pressure, mean arterial pressure, end -tidal desflurane, end-tidal CO2, and BIS were recorded at three min. intervals, for 15 minutes before and 15 minutes after the Trendelenburg position without surgical stimulus. Results: We found a significant increase in BIS values (p <0.05) after the change of position from supine to steep Trendelenburg. Heart rate, systolic blood pressure, and mean arterial pressure were almost constant.Conclusion: Our study concluded that the BIS value increases when patients were shifted from the supine to Trendelenburg position, which might raise the concern of a decrease in anesthetic depth.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Time course of cerebrovascular autoregulation during extreme Trendelenburg position for robotic-assisted prostatic surgery
    Schramm, P.
    Treiber, A. -H.
    Berres, M.
    Pestel, G.
    Engelhard, K.
    Werner, C.
    Closhen, D.
    ANAESTHESIA, 2014, 69 (01) : 58 - 63
  • [32] Effect of turning vs. supine position under phototherapy on neonates with hyperbilirubinemia: a systematic review
    Fei, Shalin Lee Wan
    Abdullah, Khatijah L.
    JOURNAL OF CLINICAL NURSING, 2015, 24 (5-6) : 672 - 682
  • [33] Effects of pneumoperitoneum and steep Trendelenburg position on cerebral hemodynamics during robotic-assisted laparoscopic radical prostatectomy A randomized controlled study
    Chen, Ke
    Wang, Lizhen
    Wang, Qing
    Liu, Xuesheng
    Lu, Yao
    Li, Yuanhai
    Wong, Gordon Tin Chun
    MEDICINE, 2019, 98 (21)
  • [34] A comparative analysis of the effects of sevoflurane and propofol on cerebral oxygenation during steep Trendelenburg position and pneumoperitoneum for robotic-assisted laparoscopic prostatectomy
    Aya Doe
    Motoi Kumagai
    Yuichiro Tamura
    Akira Sakai
    Kenji Suzuki
    Journal of Anesthesia, 2016, 30 : 949 - 955
  • [35] A comparative analysis of the effects of sevoflurane and propofol on cerebral oxygenation during steep Trendelenburg position and pneumoperitoneum for robotic-assisted laparoscopic prostatectomy
    Doe, Aya
    Kumagai, Motoi
    Tamura, Yuichiro
    Sakai, Akira
    Suzuki, Kenji
    JOURNAL OF ANESTHESIA, 2016, 30 (06) : 949 - 955
  • [36] Radiation exposure in prone vs. modified supine position during PCNL: Results with an anthropomorphic model
    St-Laurent, Marie-Pier
    Doizi, Steve
    Rosec, Maeva
    Terrasa, Jean-Baptiste
    Villa, Luca
    Traxer, Olivier
    Cloutier, Jonathan
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2019, 13 (08): : 246 - 249
  • [37] Electric impedance tomography and protective mechanical ventilation in elective robotic-assisted laparoscopy surgery with steep Trendelenburg position: a randomized controlled study
    Buonanno, Pasquale
    Marra, Annachiara
    Iacovazzo, Carmine
    Merola, Raffaele
    De Siena, Andrea Uriel
    Servillo, Giuseppe
    Vargas, Maria
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [38] Electric impedance tomography and protective mechanical ventilation in elective robotic-assisted laparoscopy surgery with steep Trendelenburg position: a randomized controlled study
    Pasquale Buonanno
    Annachiara Marra
    Carmine Iacovazzo
    Raffaele Merola
    Andrea Uriel De Siena
    Giuseppe Servillo
    Maria Vargas
    Scientific Reports, 13
  • [39] The performance of Bispectral Index in children during equi-MAC halothane vs. sevoflurane anaesthesia
    Taivainen, T.
    Klockars, J.
    Hiller, A.
    Wennervirta, J.
    van Gils, M. J.
    Suominen, P.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (11) : 933 - 939
  • [40] The Effect of Increased Intraocular Pressure During Steep Trendelenburg Positioning in Robotic Prostatectomy and Hysterectomy on Structural and Functional Ocular Parameters
    Awad, Hamdy
    Bai, Michael
    Ramadan, Mohamed Ehab
    Shabsigh, Ahmad
    Backes, Floor
    Craven, Mary Abigail
    Abdel-Rasoul, Mahmoud
    Bergese, Sergio D.
    Slabaugh, Mark
    ANESTHESIA AND ANALGESIA, 2020, 130 (04): : 975 - 982