Effect of Change of Position (Supine vs. Steep Trendelenburg) on Bispectral Index Value During Robotic Surgery

被引:0
|
作者
Kumar, Sachin [1 ]
Balyan, Rohit [2 ]
Nair, Arjun [2 ]
Tope, Rajesh [3 ]
Kumar, Vijay [3 ]
Shrivastava, Tulika [3 ]
Anshul [4 ]
Kalia, Rajni [5 ]
Kaur, Jasleen [6 ]
机构
[1] All India Inst Med Sci, Anesthesiol, New Delhi, India
[2] Maulana Azad Med Coll, Anaesthesiol, Delhi, India
[3] Indraprastha Apollo Hosp, Anaesthesiol, Delhi, ON, India
[4] Pandit Bhagwat Dayal Sharma Post Grad Inst Med Sci, Anaesthesiol, Rohtak, India
[5] Govt Med Coll & Hosp, Anaesthesiol, Chandigarh, India
[6] Maharishi Markandeshwar Univ MMU Kumarhatti Solan, Anaesthesiol, Solan, India
关键词
bis; robotic hysterectomies; robotic prostatectomies; robotic surgery; depth of anaesthesia; steep trendelenburg; bispectral index; BRAIN;
D O I
10.7759/cureus.29180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Bispectral Index (BIS) is used to monitor anesthetic depth and is a useful instrument to keep a check on intraoperative awareness. But there are various situations in which it shows false readings. Our aim of the study was to observe the changes in BIS value with steep Trendelenburg position, which is usually done, in robotic pelvic surgeries.Methods: We included 100 patients in our study who underwent robotic prostatectomies and hysterectomies. After anesthetizing the patient, the patient's heart rate, systolic blood pressure, mean arterial pressure, end -tidal desflurane, end-tidal CO2, and BIS were recorded at three min. intervals, for 15 minutes before and 15 minutes after the Trendelenburg position without surgical stimulus. Results: We found a significant increase in BIS values (p <0.05) after the change of position from supine to steep Trendelenburg. Heart rate, systolic blood pressure, and mean arterial pressure were almost constant.Conclusion: Our study concluded that the BIS value increases when patients were shifted from the supine to Trendelenburg position, which might raise the concern of a decrease in anesthetic depth.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Steep Trendelenburg position during robotic sacrocolpopexy and heart rate variability
    Lowenstein, Lior
    Mustafa, Mona
    Burke, Yechiel Z.
    Mustafa, Susana
    Segal, Dror
    Weissman, Amir
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2014, 178 : 66 - 69
  • [2] Shoulder soreness due to shoulder braces following robotic surgery in steep Trendelenburg position
    Savarkar, S. D.
    Bakshi, S. G.
    Thosar, R., V
    Sareen, R.
    SAUDI JOURNAL OF ANAESTHESIA, 2016, 10 (03) : 363 - +
  • [3] Propofol Affects Optic Nerve Sheath Diameter less than Sevoflurane during Robotic Surgery in the Steep Trendelenburg Position
    Kim, Yanghyun
    Choi, Seomun
    Kang, Sungwoo
    Park, Boram
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [4] Effect of Continuous Systemic Administration of Esmolol on Intraocular Pressure During Surgery in a Sustained Steep Trendelenburg Position
    Joo, Jin
    Kim, Jiyoung
    Lee, Jaemin
    JOURNAL OF GLAUCOMA, 2017, 26 (12) : 1068 - 1071
  • [5] Haemodynamics and cardiac function during robotic-assisted laparoscopic prostatectomy in steep Trendelenburg position
    Haas, Sebastian
    Haese, Alexander
    Goetz, Alwin E.
    Kubitz, Jens C.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (04): : 408 - 413
  • [7] Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery
    Lee, Sang Wook
    Choi, Soo Eun
    Han, Jin Hee
    Park, Sung-Wook
    Kang, Wha Ja
    Choi, Young Kyoo
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (04) : 235 - 239
  • [8] The influence of steep Trendelenburg position and CO2 pneumoperitoneum on cerebral hemodynamics during robotic prostatectomy
    Heeremans, E. H.
    Kalmar, A. F.
    Foubert, L.
    Absalom, A.
    Struys, M. M. R. F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 126 - 127
  • [9] Effects of Pneumoperitoneum and the Steep Trendelenburg Position on Heart Rate Variability and Cerebral Oxygenation during Robotic Sacrocolpopexy
    Matanes, Emad
    Weissman, Amir
    Rivlin, Aleksandr
    Lauterbach, Roy
    Amit, Amnon
    Wiener, Zeev
    Lowenstein, Lior
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2018, 25 (01) : 70 - 75
  • [10] STEEP TRENDELENBURG POSITION DURING ROBOTIC PELVIC SURGERY DOES NOT AFFECT CARDIAL FUNCTION AND HEMODYNAMIC OUTPUT AS MEASURED BY CONTINUOUS TRANSOESOPHAGEAL ECHOCARDIOGRAPHY
    Becker, Andreas
    Haas, Sebastian
    Kubitz, Thomas
    Goetz, Alwin
    Haese, Alexander
    JOURNAL OF UROLOGY, 2012, 187 (04): : E566 - E567