Adaptive nonlocal means-based regularization for statistical image reconstruction of low-dose X-ray CT

被引:2
|
作者
Zhang, Hao [1 ,2 ]
Ma, Jianhua [1 ,3 ]
Wang, Jing [4 ]
Liu, Yan [1 ]
Han, Hao [1 ]
Li, Lihong [5 ]
Moore, William [1 ]
Liang, Zhengrong [1 ,2 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
[3] Southern Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[4] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[5] CUNY Coll Staten Isl, Dept Engn Sci & Phys, Staten Isl, NY 10314 USA
关键词
X-ray CT; low-dose; adaptive nonlocal means; regularization; statistical image reconstruction; penalized weighted least-squares; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2082244
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To reduce radiation dose in X-ray computed tomography (CT) imaging, one of the common strategies is to lower the milliampere-second (mAs) setting during projection data acquisition. However, this strategy would inevitably increase the projection data noise, and the resulting image by the filtered back-projection (FBP) method may suffer from excessive noise and streak artifacts. The edge-preserving nonlocal means (NLM) filtering can help to reduce the noise-induced artifacts in the FBP reconstructed image, but it sometimes cannot completely eliminate them, especially under very low-dose circumstance when the image is severely degraded. To deal with this situation, we proposed a statistical image reconstruction scheme using a NLM-based regularization, which can suppress the noise and streak artifacts more effectively. However, we noticed that using uniform filtering parameter in the NLM-based regularization was rarely optimal for the entire image. Therefore, in this study, we further developed a novel approach for designing adaptive filtering parameters by considering local characteristics of the image, and the resulting regularization is referred to as adaptive NLM-based regularization. Experimental results with physical phantom and clinical patient data validated the superiority of using the proposed adaptive NLM-regularized statistical image reconstruction method for low-dose X-ray CT, in terms of noise/streak artifacts suppression and edge/detail/contrast/texture preservation.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction
    Xu, Jingyan
    Tsui, Benjamin M. W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 61 - 73
  • [32] SPULTRA: Low-Dose CT Image Reconstruction With Joint Statistical and Learned Image Models
    Ye, Siqi
    Ravishankar, Saiprasad
    Long, Yong
    Fessler, Jeffrey A.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (03) : 729 - 741
  • [33] A Gaussian Mixture MRF for Model-Based Iterative Reconstruction With Applications to Low-Dose X-Ray CT
    Zhang, Ruoqiao
    Ye, Dong Hye
    Pal, Debashish
    Thibault, Jean-Baptiste
    Sauer, Ken D.
    Bouman, Charles A.
    [J]. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2016, 2 (03): : 359 - 374
  • [34] LOW-DOSE X-RAY CT RECONSTRUCTION BASED ON JOINT SINOGRAM SMOOTHING AND LEARNED DICTIONARY-BASED REPRESENTATION
    Stojanovic, Ivana
    Pien, Homer
    Do, Synho
    Karl, W. Clem
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1012 - 1015
  • [35] Nonlinear sinogram smoothing for low-dose X-ray CT
    Li, TF
    Li, X
    Wang, J
    Wen, JH
    Lu, HB
    Hsieh, J
    Liang, ZR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2505 - 2513
  • [36] Simulation of image degradation in low-dose x-ray mammography
    Wanninger, F
    Treiber, O
    Panzer, W
    Regulla, D
    Winkler, G
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1102 - 1102
  • [37] Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method
    Liu, L.
    Lin, W.
    Jin, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 405 - 405
  • [38] The adaptive sinogram restoration algorithm based on anisotropic diffusion by energy minimization for low-dose X-ray CT
    Cui, Xueying
    Zhang, Quan
    Hong Shangguan
    Liu, Yi
    Gui, Zhiguo
    [J]. OPTIK, 2014, 125 (05): : 1694 - 1697
  • [39] Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT
    Srivastava, Somesh
    Fessler, Jeffrey A.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1551 - 1555
  • [40] A NEW STATISTICAL IMAGE RECONSTRUCTION ALGORITHM FOR POLYENERGETIC X-RAY CT
    Abella, Monica
    Fessler, Jeffrey A.
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 165 - 168