The adaptive sinogram restoration algorithm based on anisotropic diffusion by energy minimization for low-dose X-ray CT

被引:15
|
作者
Cui, Xueying [1 ,2 ]
Zhang, Quan [1 ]
Hong Shangguan [1 ]
Liu, Yi [1 ]
Gui, Zhiguo [1 ]
机构
[1] North Univ China, Natl Key Lab Elect Measurement Technol, Taiyuan 030051, Peoples R China
[2] Taiyuan Univ Sci & Technol, Sch Appl Sci, Taiyuan 030024, Peoples R China
来源
OPTIK | 2014年 / 125卷 / 05期
关键词
Low-dose CT; Noise reduction; Streak artifacts; Anisotropic diffusion; COMPUTED-TOMOGRAPHY; NOISE-REDUCTION;
D O I
10.1016/j.ijleo.2013.10.005
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Apparent streak artifacts will present in reconstructed images due to excessive quantum noise in low-dose X-ray imaging process. Estimating a noise-free sinogram to satisfy the filtered back-projection (FBP) reconstruction is an effective way to solve this problem. In this paper, we propose a novel sinogram noise reduction method by energy minimization. An adaptive smoothness parameter based on a modified anisotropic diffusion coefficient is applied for an optimal estimation. The smoothness parameter can make the method effectively adjust the degree of smoothness according to the noise level and the region feature in the sinogram. Visual effect together with quantitative analysis of the experimental result shows the developed approach has the excellent performance in protection of the edge and removal of streak artifacts in the reconstructed image. (C) 2013 Elsevier GmbH. All rights reserved.
引用
收藏
页码:1694 / 1697
页数:4
相关论文
共 50 条
  • [1] A statistical iteration approach with energy minimization to sinogram noise reduction for low-dose X-ray CT
    Liu, Yi
    Gui, Zhi-guo
    OPTIK, 2012, 123 (23): : 2174 - 2178
  • [2] Nonlinear sinogram smoothing for low-dose X-ray CT
    Li, TF
    Li, X
    Wang, J
    Wen, JH
    Lu, HB
    Hsieh, J
    Liang, ZR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2505 - 2513
  • [3] Bayesian sinogram smoothing with an anisotropic diffusion weighted prior for low-dose X-ray computed tomography
    Zhang, Quan
    Gui, Zhiguo
    Chen, Yang
    Li, Yuanfin
    Luo, Limin
    OPTIK, 2013, 124 (17): : 2811 - 2816
  • [4] Noise properties of low-dose X-ray CT sinogram data in Radon space
    Wang, Jing
    Lu, Hongbing
    Liang, Zhengrong
    Eremina, Daria
    Zhang, Guangxiang
    Wang, Su
    Chen, John
    Manzione, James
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [5] Adaptive Combined Denoising Based Low-dose X-ray CT Reconstruction
    Wang, Hangzhong
    Ma, Huizhu
    PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 1650 - 1653
  • [6] The statistical sinogram smoothing via adaptive-weighted total variation regularization for low-dose X-ray CT
    Cui, Xueying
    Gui, Zhiguo
    Zhang, Quan
    Liu, Yi
    Ma, Ruifen
    OPTIK, 2014, 125 (18): : 5352 - 5356
  • [7] ITERATIVE IMAGE RECONSTRUCTION FOR LOW-DOSE X-RAY CT USING A SINOGRAM RESTORATION INDUCED EDGE-PRESERVING PRIOR
    Bian, Zhaoying
    Huang, Jing
    Ma, Jianhua
    Zhang, Hua
    Liang, Zhengrong
    Chen, Wufan
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 1160 - 1163
  • [8] LOW-DOSE X-RAY CT RECONSTRUCTION BASED ON JOINT SINOGRAM SMOOTHING AND LEARNED DICTIONARY-BASED REPRESENTATION
    Stojanovic, Ivana
    Pien, Homer
    Do, Synho
    Karl, W. Clem
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1012 - 1015
  • [9] Penalized Weighted Alpha-Divergence Approach to Sinogram Restoration for Low-Dose X-ray Computed Tomography
    Bian, Zhaoying
    Ma, Jianhua
    Tian, Lingling
    Huang, Jing
    Zhang, Hua
    Zhang, Yunwan
    Chen, Wufan
    Liang, Zhengrong
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3675 - 3678
  • [10] Multiscale penalized weighted least-squares sinogram restoration for low-dose x-ray computed tomography
    Wang, Jing
    Liang, Zhengrong
    Lu, Hongbing
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1666 - +