Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study

被引:23
|
作者
Kingston, Mitchell J. [1 ,2 ]
Perriman, Diana M. [1 ,2 ]
Neeman, Teresa [3 ]
Smith, Paul N. [1 ,2 ]
Webb, Alexandra L. [1 ]
机构
[1] Australian Natl Univ, Sch Med, Coll Med Biol & Environm, 54 Mills Rd, Canberra, ACT 2601, Australia
[2] Canberra Hosp, TORU, Canberra, ACT, Australia
[3] Australian Natl Univ, Stat Consulting Unit, Canberra, ACT, Australia
关键词
micro-computed tomography; angiography; barium sulfate; lead oxide; contrast media; INJECTION TECHNIQUE; FLAP; ANATOMY;
D O I
10.1002/cmmi.1695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra-and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [41] Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography
    Lu, Li
    Zhang, Long Jiang
    Poon, Colin S.
    Wu, Sheng Yong
    Zhou, Chang Sheng
    Luo, Song
    Wang, Mei
    Lu, Guang Ming
    RADIOLOGY, 2012, 262 (02) : 605 - 612
  • [42] Assessing the three-dimensional collagen network in soft tissues using contrast agents and high resolution micro-CT: Application to porcine iliac veins
    Nierenberger, Mathieu
    Remond, Yves
    Ahzi, Said
    Choquet, Philippe
    COMPTES RENDUS BIOLOGIES, 2015, 338 (07) : 425 - 433
  • [43] Study on multi-density contrast agent fillers of duct casting based on CT three-dimensional reconstruction
    Hai-long Huang
    Jin-jun Chen
    Yu Wang
    Xiao-yu Chen
    Da-cong Gong
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2017, 37 : 300 - 306
  • [44] Study on multi-density contrast agent fillers of duct casting based on CT three-dimensional reconstruction
    Huang, Hai-long
    Chen, Jin-jun
    Wang, Yu
    Chen, Xiao-yu
    Gong, Da-cong
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2017, 37 (02) : 300 - 306
  • [45] Study on Multi-density Contrast Agent Fillers of Duct Casting Based on CT Three-Dimensional Reconstruction
    黄海龙
    陈进军
    王瑜
    陈小宇
    龚达聪
    Current Medical Science, 2017, (02) : 300 - 306
  • [46] Cerebral aneurysms diagnosis by three-dimensional CT angiography
    de Andrade, GC
    Teixeira, PAD
    Alves, HFP
    Donato, EE
    Moreira, CAA
    de Faria, RCS
    Dias, LAA
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2003, 61 (01) : 74 - 78
  • [47] Cerebral aneurysms: Evaluation with three-dimensional CT angiography
    Ogawa, T
    Okudera, T
    Noguchi, K
    Sasaki, N
    Inugami, A
    Uemura, K
    Yasui, N
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (03) : 447 - 454
  • [48] Value of three-dimensional spiral CT hepatic angiography
    Kanematsu, M
    Imaeda, T
    Mizuno, S
    Yamawaki, Y
    Sone, Y
    Lida, T
    Kato, M
    Yokoyama, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 585 - 591
  • [49] Three-dimensional CT angiography of spontaneous portosystemic shunts
    Henseler, KP
    Pozniak, MA
    Lee, FT
    Winter, TC
    RADIOGRAPHICS, 2001, 21 (03) : 691 - 704
  • [50] Three-dimensional CT angiography of the canine hepatic vasculature
    Jeong, Yucheol
    Lim, Changyun
    Oh, Sunkyoung
    Jung, Joohyun
    Chang, Jinhwa
    Yoon, Junghee
    Choi, Mincheol
    JOURNAL OF VETERINARY SCIENCE, 2008, 9 (04) : 407 - 413