Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study

被引:23
|
作者
Kingston, Mitchell J. [1 ,2 ]
Perriman, Diana M. [1 ,2 ]
Neeman, Teresa [3 ]
Smith, Paul N. [1 ,2 ]
Webb, Alexandra L. [1 ]
机构
[1] Australian Natl Univ, Sch Med, Coll Med Biol & Environm, 54 Mills Rd, Canberra, ACT 2601, Australia
[2] Canberra Hosp, TORU, Canberra, ACT, Australia
[3] Australian Natl Univ, Stat Consulting Unit, Canberra, ACT, Australia
关键词
micro-computed tomography; angiography; barium sulfate; lead oxide; contrast media; INJECTION TECHNIQUE; FLAP; ANATOMY;
D O I
10.1002/cmmi.1695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra-and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [21] Three-dimensional characterization of typical inclusions in steel by X-ray Micro-CT
    Shang, Zhiqiang
    Li, Tao
    Yang, Shufeng
    Yan, Jianchuan
    Guo, Han
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2020, 9 (03): : 3686 - 3698
  • [22] Three-dimensional reconstructed finite element model for C/C composites by micro-CT
    Zhang, Haijun
    Zhou, Chuwei
    Transactions of Nanjing University of Aeronautics and Astronautics, 2015, 32 (06) : 639 - 645
  • [23] Two- and three-dimensional MR coronary angiography with intraarterial injections of contrast agent in dogs: A feasibility study
    Green, JD
    Omary, RA
    Finn, JP
    Chung, YC
    Tang, R
    Li, YZ
    Vasireddy, S
    Li, DB
    RADIOLOGY, 2003, 226 (01) : 272 - 277
  • [24] ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals
    Dioguardi, Mario
    Troiano, Giuseppe
    Laino, Luigi
    Lo Russo, Lucio
    Giannatempo, Giovanni
    Lauritano, Floriana
    Cicciu, Marco
    Lo Muzio, Lorenzo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (10): : 17830 - 17834
  • [25] Three-dimensional analysis of the physiological foramen geometry of maxillary and mandibular molars by means of micro-CT
    Thomas Gerhard Wolf
    Frank Paqué
    Michael Sven Patyna
    Brita Willershausen
    Benjamín Brise?o-Marroquín
    International Journal of Oral Science, 2017, (03) : 151 - 157
  • [26] Three-dimensional analysis of the physiological foramen geometry of maxillary and mandibular molars by means of micro-CT
    Wolf, Thomas Gerhard
    Paque, Frank
    Patyna, Michael Sven
    Willershausen, Brita
    Briseno-Marroquin, Benjamin
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2017, 9 (03) : 151 - 157
  • [27] Three-Dimensional Cell Culture Micro-CT Visualization within Collagen Scaffolds in an Aqueous Environment
    Tkachev, Sergey
    Chepelova, Natalia
    Galechyan, Gevorg
    Ershov, Boris
    Golub, Danila
    Popova, Elena
    Antoshin, Artem
    Giliazova, Aliia
    Voloshin, Sergei
    Efremov, Yuri
    Istranova, Elena
    Timashev, Peter
    CELLS, 2024, 13 (15)
  • [28] THREE-DIMENSIONAL SEGMENTATION, RECONSTRUCTION AND PHENOTYPING ANALYSIS OF MAIZE KERNEL BASED ON MICRO-CT IMAGES
    Zhang, Ying
    Du, Jianjun
    Ma, Liming
    Pan, Xiaodi
    Wang, Jinglu
    Guo, Xinyu
    FRESENIUS ENVIRONMENTAL BULLETIN, 2018, 27 (06): : 3965 - 3969
  • [29] Three-dimensional analysis of the physiological foramen geometry of maxillary and mandibular molars by means of micro-CT
    Thomas Gerhard Wolf
    Frank Paqu
    Michael Sven Patyna
    Brita Willershausen
    Benjamn BriseoMarroqun
    International Journal of Oral Science, 2017, 9 (03) : 151 - 157
  • [30] Three-dimensional finite element modelling of all-ceramic restorations based on micro-CT
    Della Bona, Alvaro
    Borba, Marcia
    Benetti, Paula
    Duan, Yuanyuan
    Griggs, Jason A.
    JOURNAL OF DENTISTRY, 2013, 41 (05) : 412 - 419