Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study

被引:23
|
作者
Kingston, Mitchell J. [1 ,2 ]
Perriman, Diana M. [1 ,2 ]
Neeman, Teresa [3 ]
Smith, Paul N. [1 ,2 ]
Webb, Alexandra L. [1 ]
机构
[1] Australian Natl Univ, Sch Med, Coll Med Biol & Environm, 54 Mills Rd, Canberra, ACT 2601, Australia
[2] Canberra Hosp, TORU, Canberra, ACT, Australia
[3] Australian Natl Univ, Stat Consulting Unit, Canberra, ACT, Australia
关键词
micro-computed tomography; angiography; barium sulfate; lead oxide; contrast media; INJECTION TECHNIQUE; FLAP; ANATOMY;
D O I
10.1002/cmmi.1695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra-and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [1] Comparison of Three-Dimensional Micro-CT Angiography of Cervical Spinal Cord between Two Contrast Agents
    Liu, Yapu
    Liu, Qi
    Yang, Zhou
    Lin, Junyu
    Wu, Xiuhua
    Huang, Zucheng
    Liu, Junhao
    Li, Rong
    Huang, Zhiping
    Wu, Xiaoliang
    Zhu, Qingan
    CONTRAST MEDIA & MOLECULAR IMAGING, 2019,
  • [2] Three-dimensional micro-CT images for human ossicles
    Park, K
    Lee, JH
    Cho, MJ
    Won, YY
    Baek, MH
    PROCEEDINGS OF THE 3RD SYMPOSIUM ON MIDDLE EAR MECHANICS IN RESEARCH AND OTOLOGY, 2004, : 260 - 270
  • [3] Three-dimensional murine airway segmentation in micro-CT images
    Shi, Lijun
    Thiesse, Jacqueline
    McLennan, Greoffrey
    Hoffman, Eric A.
    Reinhardt, Joseph M.
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [4] A Morphometric Study of the Semicircular Canals Using Micro-CT Images in Three-Dimensional Reconstruction
    Lee, Ju-Young
    Shin, Kang-Jae
    Kim, Jeong-Nam
    Yoo, Ja-Young
    Song, Wu-Chul
    Koh, Ki-Seok
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2013, 296 (05): : 834 - 839
  • [5] Three-dimensional anatomy of the Denonvilliers' fascia after micro-CT reconstruction
    Yang, Seung Yoon
    Kim, Ho Seung
    Cho, Min Soo
    Kim, Nam Kyu
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Three-dimensional anatomy of the Denonvilliers’ fascia after micro-CT reconstruction
    Seung Yoon Yang
    Ho Seung Kim
    Min Soo Cho
    Nam Kyu Kim
    Scientific Reports, 11
  • [7] Three-dimensional CT angiography of the hepatic artery: Use of multi-detector row helical CT and a contrast agent
    Tanikake, M
    Shimizu, T
    Narabayashi, I
    Matsuki, M
    Masuda, K
    Yamamoto, K
    Uesugi, Y
    Yoshikawa, S
    RADIOLOGY, 2003, 227 (03) : 883 - 889
  • [8] Three-dimensional visual truth of the normal airway tree for use as a quantitative comparison to micro-CT reconstructions
    Thiesse, J
    Reinhardt, JM
    de Ryk, J
    Namati, E
    Leinen, J
    Recheis, W
    Hoffman, EA
    McLennan, G
    MEDICAL IMAGING 2005: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, PTS 1 AND 2, 2005, 5746 : 50 - 57
  • [9] Three-dimensional CT angiography: Comparison with conventional angiography in detection of cerebral aneurysm
    Kim, YH
    Kang, HK
    Seo, JJ
    Jeong, Y
    Kim, JK
    Park, J
    RADIOLOGY, 1996, 201 : 169 - 169
  • [10] Three-Dimensional Observation of the Pulp Cavity of Mandibular First Molars by Micro-CT
    Iwaka, Yoshiro