Torsional Resistance of Heat-Treated Nickel-Titanium Instruments under Different Temperature Conditions

被引:7
|
作者
Jo, Hyo Jin [1 ]
Kwak, Sang Won [2 ]
Kim, Hyeon-Cheol [2 ]
Kim, Sung Kyo [1 ]
Ha, Jung-Hong [1 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Conservat Dent, Daegu 41940, South Korea
[2] Pusan Natl Univ, Sch Dent, Dent Res Inst, Dept Conservat Dent, Yangsan 50612, South Korea
基金
新加坡国家研究基金会;
关键词
body temperature; C-wire; differential scanning calorimetry; electrical discharge machining; gold-wire; heat-treated nickel-titanium file; torsional resistance; ROTARY ENDODONTIC INSTRUMENTS; PHASE-TRANSFORMATION BEHAVIOR; CYCLIC FATIGUE; MECHANICAL-PROPERTIES; SEM OBSERVATIONS; FILES;
D O I
10.3390/ma14185295
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study compared the torsional resistance of heat-treated nickel-titanium (NiTi) instruments under different temperature conditions. Four thermomechanically treated single-use NiTi rotary instruments were selected for this study: OneShape (OS), OneCurve (OC), WaveOne Gold (WOG) and HyFlex EDM (HFE). Each instrument was further subdivided by temperature into 2 subgroups. Maximum torque and the distortion angle until fracture occurred were evaluated. Differential scanning calorimetry analysis was performed to measure the phase transformation temperature. Statistical analysis was performed using a two-way ANOVA and t-test (p < 0.05). Fractured fragments were observed using scanning electron microscopy (SEM). The two-way ANOVA showed no significant differences for different temperature conditions. At both room (RT) and body temperature (BT), OS was predominantly austenite while HFE was martensite. OC and WOG were predominantly martensite at RT and mixed phase at BT. At BT, more than half of WOG was martensite, while half of OC was austenite. SEM examination showed no topographical differences between instruments in different temperature groups. In relation to a limitation of this study, there was no difference in torsional resistance of NiTi rotary instruments between the BT and RT conditions. This implies that clinicians do not need to consider a decrease of torsional resistance of heat-treated NiTi instruments at BT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Cutting efficiency of conventional and heat-treated nickel-titanium rotary or reciprocating glide path instruments
    Pedulla, E.
    Leanza, G.
    La Rosa, G. R. M.
    Gueli, A. M.
    Pasquale, S.
    Plotino, G.
    Rapisarda, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (03) : 376 - 384
  • [22] Evaluation of torsional resistance of two Nickel-Titanium rotaries endodontics instruments
    Costa, C
    Santos, M
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1078 - 1078
  • [23] Dynamic cyclic and torsional fatigue resistance of TruNatomy compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    Elshazli, Alaa H.
    AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (02) : 226 - 233
  • [24] Cyclic fatigue resistance and energy dispersive X-ray spectroscopy analysis of novel heat-treated nickel-titanium instruments at body temperature
    Micoogullari Kurt, Seniha
    Kaval, Mehmet Emin
    Serefoglu, Burcu
    Kandemir Demirci, Gozde
    Caliskan, Mehmet Kemal
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (07) : 790 - 794
  • [25] Correction to: Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments
    Murilo Priori Alcalde
    Marco Antonio Hungaro Duarte
    Clovis Monteiro Bramante
    Bruno Carvalho de Vasconselos
    Mario Tanomaru-Filho
    Juliane Maria Guerreiro-Tanomaru
    Jader Camilo Pinto
    Marcus Vinicius Reis Só
    Rodrigo Ricci Vivan
    Clinical Oral Investigations, 2018, 22 : 1879 - 1879
  • [26] Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study
    Lin, Jack Han-Hsing
    Karabucak, Bekir
    Lee, Su-Min
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (02) : 738 - 743
  • [27] Torsional resistance and toughness of two nickel-titanium instruments: Reciproc versus WaveOne
    Lopes, Helio P.
    Vieira, Marcia V. B.
    Elias, Carlos N.
    Siqueira, Jose F., Jr.
    Vieira, Victor T. L.
    Mangelli, Marcelo
    Neves, Monica A. S.
    Paiva, Eloana S.
    de Paula, Cintia B.
    Soares, Renata G.
    ENDO-ENDODONTIC PRACTICE TODAY, 2014, 8 (01): : 31 - 36
  • [28] Dynamic Cyclic Fatigue Resistance of Heat-treated Nickel Titanium Instruments in Reciprocating Motion
    Sobral, Thais Kauana Magalhaes
    Piasecki, Lucila
    Tomazinho, Flavia Sens Fagundes
    Kirchhoff, Alison Luis
    Gabardo, Marilisa Carneiro Leao
    Mattos, Natanael Henrique Ribeiro
    Filho, Flares Baratto
    Fariniuk, Luiz Fernando
    EUROPEAN ENDODONTIC JOURNAL, 2023, 8 (03): : 201 - 206
  • [29] Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments
    Weissheimer, Theodoro
    Alcalde, Murilo Priori
    Cortez, Julia Barrionuevo
    da Rosa, Ricardo Abreu
    Vivan, Rodrigo Ricci
    Souza Calefi, Pedro Henrique
    Hungaro Duarte, Marco Antonio
    Reis So, Marcus Vinicius
    EUROPEAN ENDODONTIC JOURNAL, 2021, 6 (03): : 284 - 289
  • [30] Torsional Resistance of Two New Heat Treated Nickel Titanium Rotary Instruments: An in Vitro Evaluation
    Gambarini, Gianluca
    Miccoli, Gabriele
    Di Nardo, Dario
    Del Giudice, Andrea
    Mazzoni, Alessandro
    Seracchiani, Marco
    Testarelli, Luca
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2020, 20 : 1 - 7