Evaluation of dynamic and static torsional resistances of nickel-titanium rotary instruments

被引:12
|
作者
Abu-Tahun, Ibrahim H. [1 ]
Ha, Jung-Hong [2 ]
Kwak, Sang Won [3 ]
Kim, Hyeon-Cheol [3 ]
机构
[1] Univ Jordan, Sch Dent, Dept Conservat Dent, Amman, Jordan
[2] Kyungpook Natl Univ, Sch Dent, Dept Conservat Dent, Daegu, South Korea
[3] Pusan Natl Univ, Sch Dent, Dent Res Inst, Dept Conservat Dent, Yangsan, South Korea
关键词
Fracture; Nickel-titanium rotary instrument; Torsional resistance; Dynamic repetitive load; Static rotation; CYCLIC FATIGUE RESISTANCE; ENDODONTIC INSTRUMENTS; CLINICAL-USE; METALLURGICAL CHARACTERIZATION; FILES; WIRE; DEFORMATION; DEFECTS; FAILURE; PROFILE;
D O I
10.1016/j.jds.2017.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: This study evaluated the torsional resistances of nickel-titanium rotary instruments by two methods: i) dynamic resistance: repetitive torsional loading (RTL) and ii) static resistance: single torsional loading (STL) based on the International Organization for Standardization. Materials and methods: In RTL method, a pre-set rotational loading (0.5 N cm) was applied after fixing the 3-mm tip of the file, and this clockwise loading to the pre-set torque and counterclockwise unloading to original position was repeated at 50 rpm until the file fractured. The number of repetition cycles until fracture was counted. In STL method, the torsional strength was determined by continuous clockwise rotation (2 rpm) until fracture. Results from both methods were compared after testing the torsional resistances of four instrument systems (n = 15): Hyflex CM, HyFlex EDM, V-Taper2, and V-Taper2H. A scanning electron microscope (SEM) was used to examine the topographic features of the fractured surfaces and longitudinal aspects (n = 5) from both methods. Results: The RTL and STL methods had similar results: V-Taper2 had the highest resistance and the Hyflex CMhad the lowest (P < 0.05). Spearman correlation test showed the results from two methods were strongly correlated (coefficient = 1). Under the SEM, specimens from the RTLshowed ruptured aspects on cross-sections with multiple areas of crack propagation, while the STLshowed the typical features of torsional failure such as circular abrasion marks and fatigue dimples. Conclusions: This study suggests the clinically relevant torsional test (RTL) method yield similar results with the STL method, but they have different topographic findings. (C) 2018 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [21] Comparing apical preparations of root canals shaped by nickel-titanium rotary instruments and nickel-titanium hand instruments
    Deplazes, P
    Peters, O
    Barbakow, F
    JOURNAL OF ENDODONTICS, 2001, 27 (03) : 196 - 202
  • [22] Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
    Ullmann, CJ
    Peters, OA
    JOURNAL OF ENDODONTICS, 2005, 31 (03) : 183 - 186
  • [23] Influence of Combined Cyclic Fatigue and Torsional Stress on the Fracture Point of Nickel-Titanium Rotary Instruments
    Setzer, Frank C.
    Boehme, Christian P.
    JOURNAL OF ENDODONTICS, 2013, 39 (01) : 133 - 137
  • [24] Factors influencing the fracture of nickel-titanium rotary instruments
    Martín, B
    Zelada, G
    Varela, P
    Bahillo, JG
    Magán, F
    Ahn, S
    Rodríguez, C
    INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (04) : 262 - 266
  • [25] Dentine chips produced by nickel-titanium rotary instruments
    Guppy, DR
    Curtis, RV
    Ford, TRP
    ENDODONTICS & DENTAL TRAUMATOLOGY, 2000, 16 (06): : 258 - 264
  • [26] A cleaning protocol for rotary nickel-titanium endodontic instruments
    Parashos, P
    Linsuwanont, P
    Messer, HH
    AUSTRALIAN DENTAL JOURNAL, 2004, 49 (01) : 20 - 27
  • [27] Nickel-Titanium Rotary Instruments: Mechanical and Metallurgical Characteristics
    Zanza, Alessio
    Reda, Rodolfo
    Testarelli, Luca
    CLINICS AND PRACTICE, 2022, 12 (01) : 94 - 96
  • [28] Electrochemical Properties of Nickel-Titanium Rotary Endodontic Instruments
    Subramanian, Vidyalakshmi
    Roberts, Howard W.
    Han, Shengtong
    Sidow, Stephanie J.
    Berzins, David W.
    JOURNAL OF ENDODONTICS, 2024, 50 (08) : 1143 - 1150
  • [29] Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments
    Weissheimer, Theodoro
    Alcalde, Murilo Priori
    Cortez, Julia Barrionuevo
    da Rosa, Ricardo Abreu
    Vivan, Rodrigo Ricci
    Souza Calefi, Pedro Henrique
    Hungaro Duarte, Marco Antonio
    Reis So, Marcus Vinicius
    EUROPEAN ENDODONTIC JOURNAL, 2021, 6 (03): : 284 - 289
  • [30] Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature
    Yilmaz, K.
    Uslu, G.
    Gundogar, M.
    Ozyurek, T.
    Grande, N. M.
    Plotino, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (08) : 924 - 930