Single breath-hold 3D contrast-enhanced method for assessment of cardiac function

被引:0
|
作者
Barger, AV
Grist, TM
Block, WF
Mistretta, CA
机构
[1] Univ Wisconsin, Ctr Clin Sci, Dept Radiol, Sch Med, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Sch Med, Dept Radiol, Madison, WI USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[5] Univ Wisconsin, Sch Med, Dept Biomed Engn, Madison, WI USA
关键词
MR cardiac imaging; fast magnetic resonance imaging; projection reconstruction;
D O I
10.1002/1522-2594(200012)44:6<821::AID-MRM1>3.0.CO;2-S
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac MRI function measurements are typically performed using 2D sequences and require multiple breath-holds to image the entire heart. A single 3D acquisition using a T-1-shortening agent has many potential advantages over techniques that acquire multiple 2D images, including more consistent contrast and precise slice coverage. However, 3D techniques currently require much longer than a single breath-hold to complete. It has been shown that for MR angiography undersampled projection reconstruction can acquire much higher resolution per unit time than Fourier imaging with acceptable artifacts. By employing a gated, undersampled projection technique, high-resolution 3D multiphase volumes of the heart can be acquired in a single breath-hold. Short repetition times result in good myocardial suppression and a temporal aperture of 60 ms. (C) 2000 Wiley-Liss, Inc.
引用
下载
收藏
页码:821 / 824
页数:4
相关论文
共 50 条
  • [41] Single breath-hold Vd(m) calculation as good as multi breath-hold technique in Equilibrium Contrast CMR
    Daniel Sado
    Stefan K Piechnik
    Matthew D Robson
    Viviana Maestrini
    Andrew Flett
    Steven K White
    Sanjay M Banypersad
    James Moon
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [42] Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts
    Vrachliotis, TG
    Bis, KG
    Aliabadi, D
    Shetty, AN
    Safian, R
    Simonetti, O
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) : 1073 - 1080
  • [43] High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation
    Carr, JC
    Ma, J
    Desphande, V
    Pereles, S
    Laub, G
    Finn, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 543 - 549
  • [44] Takayasu arteritis: Evaluation with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Shibuya, H
    Numano, F
    RADIOLOGY, 1998, 209P : 495 - 495
  • [45] Diagnostic performance of contrast-enhanced breath-hold MR imaging in the detection and differentiation of renal lesions
    Krestin, GP
    Hauser, M
    Goehde, SC
    Knecht, M
    HuchBoeni, RA
    Debatin, JF
    RADIOLOGY, 1996, 201 : 104 - 104
  • [46] Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation
    Ernst, O
    Asnar, V
    Sergent, G
    Lederman, E
    Nicol, L
    Paris, JC
    L'Herminé, C
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 433 - 439
  • [47] Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis
    Alistair A Young
    Brett R Cowan
    Stefan O Schoenberg
    Bernd J Wintersperger
    Journal of Cardiovascular Magnetic Resonance, 10
  • [48] Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis
    Young, Alistair A.
    Cowan, Brett R.
    Schoenberg, Stefan O.
    Wintersperger, Bernd J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [49] Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, E
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 345 - 348
  • [50] Takayasu arteritis: Diagnosis with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Kobayashi, Y
    Numano, F
    Shibuya, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (05): : 481 - 487