Takayasu arteritis: Diagnosis with breath-hold contrast-enhanced three-dimensional MR angiography

被引:1
|
作者
Yamada, I [1 ]
Nakagawa, T [1 ]
Himeno, Y [1 ]
Kobayashi, Y [1 ]
Numano, F [1 ]
Shibuya, H [1 ]
机构
[1] Tokyo Med & Dent Univ, Fac Med, Dept Radiol, Bunkyo Ku, Tokyo 1138519, Japan
来源
关键词
Takayasu arteritis; MR angiography; contrast media;
D O I
10.1002/(SICI)1522-2586(200005)11:5<481::AID-JMRI3>3.0.CO;2-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the study was to determine the diagnostic accuracy of breath-hold contrast-enhanced three-dimensional (3D) magnetic resonance (MR) angiography in Takayasu arteritis. Thirty patients suspected of having Takayasu arteritis were examined with MR angiography and conventional angiography. Takayasu arteritis was diagnosed in 20 of these patients. MR angiography was performed using a 1.5-T system after bolus injection of 0.1 mmol/kg of gadodiamide. MR angiography clearly depicted various vascular lesions In the aorta and its major branches in all 20 patients with Takayasu arteritis, It also depicted pulmonary artery lesions in 10 (50%) of the 20 patients. MR angiography accurately depicted 323 (98%) of 330 arteries, but 7 (2%) stenotic arteries were overestimated as occluded. The sensitivity and specificity of MR angiography for the diagnosis of Takayasu arteritis were both 100%. Breath-hold contrast-enhanced 3D MR angiography clearly depicts various vascular lesions in both the systemic and pulmonary arteries in Takayasu arteritis, thus allowing a definitive diagnosis of Takayasu arteritis, (C) 2000 Wiley-Liss. Inc.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 50 条
  • [1] Takayasu arteritis: Evaluation with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Shibuya, H
    Numano, F
    [J]. RADIOLOGY, 1998, 209P : 495 - 495
  • [2] Breath-hold, contrast-enhanced, three-dimensional MR angiography
    Leung, DA
    McKinnon, GC
    Davis, CP
    Pfammatter, T
    Krestin, GP
    Debatin, JF
    [J]. RADIOLOGY, 1996, 200 (02) : 569 - 571
  • [3] Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, E
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 345 - 348
  • [4] Optimization of contrast timing for breath-hold three-dimensional MR angiography
    Hany, TF
    McKinnon, GC
    Leung, DA
    Pfammatter, T
    Debatin, JF
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 551 - 556
  • [5] Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience
    Kessler, W
    Laub, G
    Achenbach, S
    Ropers, D
    Moshage, W
    Daniel, WG
    [J]. RADIOLOGY, 1999, 210 (02) : 566 - 572
  • [6] Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    Hany, TF
    Debatin, JF
    Leung, DA
    Pfammatter, T
    [J]. RADIOLOGY, 1997, 204 (02) : 357 - 362
  • [7] Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    Li, DB
    Carr, JC
    Shea, SM
    Zheng, J
    Deshpande, VS
    Wielopolski, PA
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (01) : 270 - 277
  • [8] Magnetic resonance urography by breath-hold contrast-enhanced three-dimensional FISP
    Li, W
    Chavez, D
    Edelman, RR
    Prasad, PV
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 309 - 311
  • [9] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    [J]. RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [10] Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation
    Ernst, O
    Asnar, V
    Sergent, G
    Lederman, E
    Nicol, L
    Paris, JC
    L'Herminé, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 433 - 439