Optical analysis of gel dosimeters: Comparison of Fricke and normoxic polymer gels

被引:4
|
作者
Gambarini, G.
Carrara, M.
Mariani, A.
Pirola, L.
Tomatis, S.
Valente, M.
Vanossi, E.
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[3] Politecn Milan, Dept Nucl Engn, Milan, Italy
[4] Natl Canc Inst, Dept Phys, Milan, Italy
关键词
dose imaging; Fricke gel; polymer gel; gel dosimetry; optical imaging; phantoms;
D O I
10.1016/j.nimb.2007.04.085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimetry method based on optical analysis of gel layers has been experienced utilising both Fricke and polymer (normoxic) gels. The aim of the work was that of investigating the potentiality of a normoxic polymer gel and of performing a further verification of the reliability of Fricke gel dosimeters. Optical absorbance was measured, both with a spectrophotometer and by imaging light transmittance detected with a CCD camera. The results of the study of sensitivity, linearity of the response and reproducibility of the polymer gel dosimeter have shown acceptable performances, except for doses below 2 Gy. The linearity range extends up to 20 Gy. On the other side, dose images and profiles have shown noticeable differences when compared to those calculated or measured with ionisation chambers or Fricke gel dosimeters. Such Fricke dosimeters have given further confirmation of their reliability. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [1] Investigation of the characteristics of fricke and normoxic polymer gel dosimeters with optical, magnetic resonance and computed tomography readout systems
    Baldock, Clive
    [J]. JOURNAL OF MEDICAL PHYSICS, 2007, 32 (03) : 133 - 134
  • [2] The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels
    De Deene, Y
    Vergote, K
    Claeys, C
    De Wagter, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03): : 653 - 673
  • [3] Radiological properties of normoxic polymer gel dosimeters
    Venning, AJ
    Nitschke, KN
    Keall, PJ
    Baldock, C
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 1047 - 1053
  • [4] Investigation of the radiological properties of normoxic polymer gel dosimeters
    Venning, A
    Nitschke, K
    Baldock, C
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1898 - 1898
  • [5] A basic study of some normoxic polymer gel dosimeters
    De Deene, Y
    Hurley, C
    Venning, A
    Vergote, K
    Mather, M
    Healy, BJ
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19): : 3441 - 3463
  • [6] Experimental study of attenuation properties of normoxic polymer gel dosimeters
    Brindha, S
    Venning, AJ
    Hill, B
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (20): : N353 - N361
  • [7] The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters
    De Deene, Y.
    Pittomvils, G.
    Visalatchi, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (10): : 2719 - 2728
  • [8] Experimental investigation of the attenuation properties of normoxic polymer gel dosimeters
    Brindha, S
    Venning, A
    Hill, B
    Baldock, C
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1886 - 1886
  • [9] Optical Evaluation of normoxic PAGAT polymer gel dosimeters used to measure SWDP on diagnostic CT scanners
    Sarabipour, Sarvenaz
    Bosi, Stephen
    Hill, Brendan
    Baldock, Clive
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1606 - 1608
  • [10] The effect of x-ray CT dose on normoxic polymer gel dosimeters
    Baxter, P.
    Jirasek, A.
    Hilts, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S56 - S56