Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics

被引:22
|
作者
Morales, Hernan G. [1 ]
Bonnefous, Odile [1 ]
机构
[1] Medisys Philips Res Paris, Paris, France
关键词
Cerebral aneurysms; Hemodynamics; CFD; Wall shear stress; flow rate; WALL SHEAR-STRESS; RATE WAVE-FORMS; CEREBRAL ANEURYSMS; INTRACRANIAL ANEURYSMS; QUANTIFICATION; MOTION;
D O I
10.1016/j.jbiomech.2015.01.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R-2 > 0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R-2 > 0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 50 条
  • [41] Computational fluid dynamics modeling of intracranial aneurysms: Effects of parent artery segmentation on intra-aneurysmal hemodynamics
    Castro, M. A.
    Putman, C. M.
    Cebral, J. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (08) : 1703 - 1709
  • [42] TREATMENT OF GIANT ANEURYSMS BY INTRA-ANEURYSMAL CUPROUS WIRING
    CROCKARD, HA
    GORDON, DS
    ACTA NEUROCHIRURGICA, 1979, 46 (1-2) : 173 - 173
  • [43] Peak systolic or maximum intra-aneurysmal hemodynamic condition? Implications on normalized flow variables
    Morales, Hernan G.
    Bonnefous, Odile
    JOURNAL OF BIOMECHANICS, 2014, 47 (10) : 2362 - 2370
  • [44] Individualized risk assessment of recanalization of visceral aneurysms using stagnation of intra-aneurysmal flow
    Kamada H.
    Nakamura M.
    Ota H.
    Oguro S.
    Higuchi S.
    Sato T.
    Takase K.
    Journal of Biorheology, 2023, 37 (02) : 73 - 82
  • [45] Qualitative comparison of intra-aneurysmal flow structures determined from conventional and virtual angiograms
    Cebral, Juan R.
    Radaelli, Alessandro
    Frangi, Alejandro
    Putman, Christopher M.
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [46] Real Time Evaluation of Flow Patterns of AAA Depending on Intra-aneurysmal Thrombosis Using Aneurysm Flow
    Kim, Jang Yong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S266 - S266
  • [47] CFD to Quantify Idealized Intra-Aneurysmal Blood Flow in Response to Regular and Flow Diverter Stent Treatment
    Sanches, Augusto Fava
    Shit, Suprosanna
    Oezpeynirci, Yigit
    Liebig, Thomas
    FLUIDS, 2022, 7 (08)
  • [48] The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry
    Dorn, Franziska
    Niedermeyer, Franz
    Balasso, Andrea
    Liepsch, Dieter
    Liebig, Thomas
    NEURORADIOLOGY, 2011, 53 (04) : 267 - 272
  • [49] Critical Influence of Framing Coil Orientation on Intra-Aneurysmal and Neck Region Hemodynamics in a Sidewall Aneurysm Model COMMENTS
    Nozaki, Kazuhiko
    Baimeedi, Praveen R.
    Ture, Ugur
    Murayama, Yuichi
    NEUROSURGERY, 2010, 67 (06) : 1702 - 1702
  • [50] The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry
    Franziska Dorn
    Franz Niedermeyer
    Andrea Balasso
    Dieter Liepsch
    Thomas Liebig
    Neuroradiology, 2011, 53 : 267 - 272