Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics

被引:22
|
作者
Morales, Hernan G. [1 ]
Bonnefous, Odile [1 ]
机构
[1] Medisys Philips Res Paris, Paris, France
关键词
Cerebral aneurysms; Hemodynamics; CFD; Wall shear stress; flow rate; WALL SHEAR-STRESS; RATE WAVE-FORMS; CEREBRAL ANEURYSMS; INTRACRANIAL ANEURYSMS; QUANTIFICATION; MOTION;
D O I
10.1016/j.jbiomech.2015.01.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R-2 > 0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R-2 > 0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 50 条
  • [31] A Modified Method for Creating Elastase Induced Aneurysms and Characterization of Intra-Aneurysmal Flow
    Safinia, Cyrus
    Bachour, Salam
    Hevesi, Mario
    Divani, Afshin
    NEUROLOGY, 2016, 86
  • [32] Changes of intra-aneurysmal pressure during coiling
    Wakhloo, AK
    Lieber, BB
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (03) : 471 - 472
  • [33] Intra-aneurysmal blood flow based on patient-specific CT angiogram
    Morino, Taku
    Tanoue, Tetsuya
    Tateshima, Satoshi
    Vinuela, Fernando
    Tanishita, Kazuo
    EXPERIMENTS IN FLUIDS, 2010, 49 (02) : 485 - 496
  • [34] Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow
    Lieber, BB
    Livescu, V
    Hopkins, LN
    Wakhloo, AK
    ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (06) : 768 - 777
  • [35] Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow
    Baruch B. Lieber
    Veronica Livescu
    L. N. Hopkins
    Ajay K. Wakhloo
    Annals of Biomedical Engineering, 2002, 30 : 768 - 777
  • [36] Intra-aneurysmal blood flow based on patient-specific CT angiogram
    Taku Morino
    Tetsuya Tanoue
    Satoshi Tateshima
    Fernando Vinuela
    Kazuo Tanishita
    Experiments in Fluids, 2010, 49 : 485 - 496
  • [37] AN ALTERNATIVE METHOD FOR CREATING ELASTASE INDUCED ANEURYSMS AND CHARACTERIZATION OF INTRA-ANEURYSMAL FLOW
    Safina, C.
    Bachour, S.
    Hevesi, M.
    Rulau, A.
    Kapil, N.
    Divani, A.
    INTERNATIONAL JOURNAL OF STROKE, 2016, 11 (SUPP 3) : 65 - 65
  • [38] Critical Influence of Framing Coil Orientation on Intra-Aneurysmal and Neck Region Hemodynamics in a Sidewall Aneurysm Model
    Schirmer, Clemens M.
    Malek, Adel M.
    NEUROSURGERY, 2010, 67 (06) : 1692 - 1702
  • [39] Can aspect ratio be used to categorize intra-aneurysmal hemodynamics?-A study of elastase induced aneurysms in rabbit
    Zeng, Zijing
    Durka, Michael J.
    Kallmes, David F.
    Ding, Yonghong
    Robertson, Anne M.
    JOURNAL OF BIOMECHANICS, 2011, 44 (16) : 2809 - 2816
  • [40] Intra-Aneurysmal Pressure and Flow Changes Induced by Flow Diverters: Relation to Aneurysm Size and Shape
    Larrabide, I.
    Aguilar, M. L.
    Morales, H. G.
    Geers, A. J.
    Kulcsar, Z.
    Ruefenacht, D.
    Frangi, A. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (04) : 816 - 822