Ocular Pulse Amplitude Before and After Cataract Surgery

被引:8
|
作者
Plange, Niklas [1 ]
Rennings, Corinna [1 ]
Herr, Anne [1 ]
Weber, Anke [1 ]
Roessler, Gernot F. [1 ]
Mazinani, Babac E. [1 ]
Kaup, Marion [1 ]
Remky, Andreas [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Dept Ophthalmol, D-52057 Aachen, Germany
[2] Augenbelegabteilung Krankenhaus Barmherzige Brued, Regensburg, Germany
关键词
Ocular blood flow; Ocular pulse amplitude; Dynamic contour tonometry; Intraocular pressure; Cataract surgery; DYNAMIC CONTOUR TONOMETRY; CHOROIDAL BLOOD-FLOW; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; PERFUSION-PRESSURE; FUNDUS PULSE; PULSATILE; HEMODYNAMICS; DEPENDENCE; RIGIDITY;
D O I
10.3109/02713683.2011.626910
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the impact of cataract surgery on the association of the ocular pulse amplitude (OPA) and intraocular pressure (IOP) with respect to the interpretation of OPA as an estimate of ocular blood flow. Methods: Twenty-four patients with cataract were included in a clinical study. OPA was measured using dynamic contour tonometry (DCT, Pascal (R), SMT Swiss Microtechnology AG, Switzerland). IOP was measured by means of Goldmann applanation tonometry (IOP GAT) and DCT (IOP DCT). All measurements were performed before and one day after cataract surgery. Results: At baseline, OPA was correlated to IOP GAT (r = 0.67, P = 0.0002) and IOP DCT (r = 0.82, P < 0.0001), but not to age or axial length. Postoperative OPA was correlated to IOP GAT (r = 0.67, P = 0.0002) and IOP DCT (r = 0.65, P = 0.0004). In 17 patients, IOP GAT decreased after surgery (IOP DCT n = 14), whereas an increase was apparent in seven patients (IOP DCT n = 10). The mean absolute deviation of IOP GAT pre- to post-surgery was 4.54 mmHg +/- 2.47 (range 1-10 mmHg) and 5.4 mmHg +/- 3.2 (range 1.1-13.1 mmHg) for IOP DCT. The changes of OPA were significantly correlated to changes in IOP GAT (r = 0.48, P = 0.017) and IOP DCT (r = 0.60, P = 0.001). IOP GAT and IOP DCT changes were not correlated to changes in corneal thickness. Conclusions: The OPA measured with the Pascal (R) device seems to be dependent on IOP changes. Particular caution should be taken in the interpretation of OPA in estimating pulsatile ocular blood flow.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 50 条
  • [41] Rarebit perimetry and fovea test before and after cataract surgery
    Nilsson, Maria
    Abdiu, Oran
    Laurell, Carl-Gustaf
    Martin, Lene
    ACTA OPHTHALMOLOGICA, 2010, 88 (04) : 479 - 482
  • [42] Colour Vision Sensitivity Changes Before and After Cataract Surgery
    Jansone, Zane
    Ozolinsh, Maris
    PERCEPTION, 2018, 47 (05) : 564 - 564
  • [43] GLARE AND MESOPIC VISION BEFORE AND AFTER CATARACT-SURGERY
    WEISS, JF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01): : 88 - 91
  • [45] Evaluation of subfoveal choroidal thickness before and after cataract surgery
    Tanigawa, Minoru
    Shimada, Yuu
    Ochiai, Yuko
    Ochiai, Haruyuki
    Tsukahara, Yoko
    Yamanaka, Hiromitsu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [46] Change in Sleep State of the Elderly before and after Cataract Surgery
    Tanaka, Mizuho
    Hosoe, Kyoko
    Hamada, Tsunekazu
    Morita, Takeshi
    JOURNAL OF PHYSIOLOGICAL ANTHROPOLOGY, 2010, 29 (06): : 219 - 224
  • [47] Microarchitecture of Schlemm Canal Before and After Cataract Extraction Surgery
    Rubinstein, Yair
    Fogel-Levin, Miri
    Singer, Reut
    Levkovitch-Verbin, Hani
    Moros, Iris
    Sher, Ifat
    Rotenstreich, Ygal
    Skaat, Alon
    JOURNAL OF GLAUCOMA, 2019, 28 (08) : 727 - 731
  • [48] Laser scanning topometry and polarimetry before and after cataract surgery
    Pflug, A
    Kremmer, S
    Selbach, JM
    Heiligenhaus, A
    Steuhl, KP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3897 - 3897
  • [49] A prospective study of the rate of falls before and after cataract surgery
    Brannan, S
    Dewar, C
    Sen, J
    Clarke, D
    Marshall, T
    Murray, PI
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (05) : 560 - 562
  • [50] Comparing the multifocal electroretinogram topography before and after cataract surgery
    Tam, WK
    Chan, H
    Brown, B
    Leung, KW
    Woo, V
    Yap, M
    CURRENT EYE RESEARCH, 2005, 30 (07) : 593 - 599