Ocular Pulse Amplitude Before and After Cataract Surgery

被引:8
|
作者
Plange, Niklas [1 ]
Rennings, Corinna [1 ]
Herr, Anne [1 ]
Weber, Anke [1 ]
Roessler, Gernot F. [1 ]
Mazinani, Babac E. [1 ]
Kaup, Marion [1 ]
Remky, Andreas [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Dept Ophthalmol, D-52057 Aachen, Germany
[2] Augenbelegabteilung Krankenhaus Barmherzige Brued, Regensburg, Germany
关键词
Ocular blood flow; Ocular pulse amplitude; Dynamic contour tonometry; Intraocular pressure; Cataract surgery; DYNAMIC CONTOUR TONOMETRY; CHOROIDAL BLOOD-FLOW; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; PERFUSION-PRESSURE; FUNDUS PULSE; PULSATILE; HEMODYNAMICS; DEPENDENCE; RIGIDITY;
D O I
10.3109/02713683.2011.626910
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the impact of cataract surgery on the association of the ocular pulse amplitude (OPA) and intraocular pressure (IOP) with respect to the interpretation of OPA as an estimate of ocular blood flow. Methods: Twenty-four patients with cataract were included in a clinical study. OPA was measured using dynamic contour tonometry (DCT, Pascal (R), SMT Swiss Microtechnology AG, Switzerland). IOP was measured by means of Goldmann applanation tonometry (IOP GAT) and DCT (IOP DCT). All measurements were performed before and one day after cataract surgery. Results: At baseline, OPA was correlated to IOP GAT (r = 0.67, P = 0.0002) and IOP DCT (r = 0.82, P < 0.0001), but not to age or axial length. Postoperative OPA was correlated to IOP GAT (r = 0.67, P = 0.0002) and IOP DCT (r = 0.65, P = 0.0004). In 17 patients, IOP GAT decreased after surgery (IOP DCT n = 14), whereas an increase was apparent in seven patients (IOP DCT n = 10). The mean absolute deviation of IOP GAT pre- to post-surgery was 4.54 mmHg +/- 2.47 (range 1-10 mmHg) and 5.4 mmHg +/- 3.2 (range 1.1-13.1 mmHg) for IOP DCT. The changes of OPA were significantly correlated to changes in IOP GAT (r = 0.48, P = 0.017) and IOP DCT (r = 0.60, P = 0.001). IOP GAT and IOP DCT changes were not correlated to changes in corneal thickness. Conclusions: The OPA measured with the Pascal (R) device seems to be dependent on IOP changes. Particular caution should be taken in the interpretation of OPA in estimating pulsatile ocular blood flow.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 50 条
  • [31] Ocular surface dysfunction and tear osmolarity after cataract surgery
    Kuzmiene, L.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [32] Reasons for early ocular hypertension after uneventful cataract surgery
    Fan, Fan
    Luo, Yi
    Lu, Yi
    Liu, Xin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (05) : 712 - 717
  • [33] Change in ocular alignment after topical anesthetic cataract surgery
    Chung, Seung Ah
    Kim, Chan Yoon
    Chang, Jee Ho
    Hong, Samin
    Kang, Sung Yong
    Seong, Gong Je
    Lee, Jong Bok
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (09) : 1269 - 1272
  • [34] Change in ocular alignment after topical anesthetic cataract surgery
    Seung Ah Chung
    Chan Yoon Kim
    Jee Ho Chang
    Samin Hong
    Sung Yong Kang
    Gong Je Seong
    Jong Bok Lee
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1269 - 1272
  • [35] Evaluation of ocular pulse amplitude changes after the retinal detachment repair
    Jeremic, Miroslav
    Kovacevic, Igor
    Vasilijevic, Jelena
    Kalezic, Tanja
    Bozic, Marija
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (10) : 3607 - 3609
  • [36] Changes in intra-ocular pressure, ocular pulse amplitude and choroidal thickness after trabeculectomy
    Cicek, Ugur
    Garip, Ruveyde
    Solmaz, Banu
    Altan, Cigdem
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (01) : 36 - 40
  • [37] OCULAR PULSE AMPLITUDE AND PULSATILE OCULAR BLOOD-FLOW IN RETINAL-DETACHMENT AND FOLLOWING SURGERY
    SCHMIDT, KG
    VONRUCKMANN, A
    SCHMIDT, W
    PAVLOVIC, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1536 - 1536
  • [38] Dry eye signs and symptoms before and after cataract surgery
    Recchioni, Alberto
    Bhogal, Gurpreet
    Aujla, Maana
    Wolffsohn, James Stuart
    Kolli, Sai
    Hartwig, Andreas
    O'Donnell, Clare
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [39] Glare disability and contrast sensitivity before and after cataract surgery
    Superstein, R
    Boyaner, D
    Overbury, O
    Collin, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (02): : 248 - 253
  • [40] Binocular Vision Characteristics in Patients before and after Cataract Surgery
    Tan, Qing-Qing
    Lewis, James S.
    Scheiman, Mitchell
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)