Validation of GATE Monte Carlo simulations for Siemens PET/CT and PET/MR systems

被引:0
|
作者
Kertesz, H. [1 ]
Renner, A. [1 ]
Rausch, I. [1 ]
Beyer, T. [1 ]
Cal-Gonzalez, J. [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EP-0020
引用
收藏
页码:S298 / S299
页数:2
相关论文
共 50 条
  • [31] Validation of a GATE model for the simulation of the Siemens biograph™ 6 PET scanner
    Gonias, P.
    Bertsekas, N.
    Karakatsanis, N.
    Saatsakis, G.
    Gaitanis, A.
    Nikolopoulos, D.
    Loudos, G.
    Papaspyrou, L.
    Sakellios, N.
    Tsantilas, X.
    Daskalakis, A.
    Liaparinos, P.
    Nikita, K.
    Louizi, A.
    Cavouras, D.
    Kandarakis, I.
    Panayiotakis, G. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 263 - 266
  • [32] Experimental validation of a PET Monte-Carlo simulator
    Le Meunier, L
    Mathy, F
    Fagret, D
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3343 - 3346
  • [33] Unified description and validation of Monte Carlo simulators in PET
    Buvat, I
    Castiglioni, I
    Feuardent, J
    Gilardi, MC
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 329 - 346
  • [34] Unified description and validation of Monte Carlo simulators in PET
    Buvat, I
    Castiglioni, I
    Feuardent, J
    Gilardi, MC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2554 - 2558
  • [35] Monte Carlo Simulation of The GE LYSO-Based Discovery RX PET/CT Scanner Using GATE: a Validation Study
    Geramifar, P.
    Ay, M. R.
    Zafarghandi, M. Shamsaii
    Loudos, G.
    Rahmim, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S175 - S176
  • [36] Monte Carlo simulation in PET and SPECT instrumentation using GATE
    Assié, K
    Breton, V
    Buvat, I
    Comtat, C
    Jan, S
    Krieguer, M
    Lazaro, D
    Morel, C
    Rey, M
    Santin, G
    Simon, L
    Staelens, S
    Strul, D
    Vieira, JM
    Van de Walle, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 180 - 189
  • [37] Current Trends in PET and Combined (PET/CT and PET/MR) Systems Design
    Zaidi, Habib
    Alavi, Abass
    PET CLINICS, 2007, 2 (02) : 109 - 123
  • [38] Validation of gate Monte Carlo simulations for indium 111 imaging
    Assié, K
    Gardin, I
    Véra, P
    Buvat, I
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4023 - 4027
  • [39] Validation of a GATE simulation model for the siemens PET/CT biograph™ 6 scanner, using NEMA 2001 standards
    Gonias, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S137 - S137
  • [40] Monte Carlo simulations of the count rate performance of a clinical whole-body MR/PET scanner
    Delso, Gaspar
    Martinez, Maria-Jose
    Torres, Irene
    Ladebeck, Ralf
    Michel, Christian
    Nekolla, Stephan
    Ziegler, Sibylle I.
    MEDICAL PHYSICS, 2009, 36 (09) : 4126 - 4135