Experimental validation of a PET Monte-Carlo simulator

被引:0
|
作者
Le Meunier, L [1 ]
Mathy, F [1 ]
Fagret, D [1 ]
机构
[1] CEA Grenoble, LETI, F-38054 Grenoble, France
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
As with most PET simulators, the widely used SimSET (a Simulation System for Emission Tomography) package still needs to be thoroughly validated. This paper presents the continuation of a comparison between simulations and experimental validation data obtained on two cylindrical SIEMENS tomographs: the ECAT HR+ and the ECAT ACCEL. The 2D and 3D sensitivities were simulated. The standard 2D collimator module did not give good results, so we described the 2D collimator inside the phantom. As the standard version of SIMSET does not describe block detectors, the sensitivity is corrected by the square of the ratio between the volume of the detector blocks and the volume of the full detector ring. The agreement is good for 2D and 3D as well for the HR+ tomograph, a little less satisfactory for the ACCEL tomograph. The standard SimSET computes the centroid of the photon interaction in the detector ring. As there is no Depth Of Interaction measurement on these machines, the spatial resolution was simulated with the hit in the detector projected onto the input side of the detector. Thus, with this simple correction, the spatial resolution is in correct agreement with experimental data, the discrepancy increases of course if quite far from the axis. Most simulations were done with and without variance reduction techniques. The agreement between them is good. Complementary comparisons are presented, such as energy spectra of a water cylinder phantom outside the Field Of View for the ACCEL machine.
引用
收藏
页码:3343 / 3346
页数:4
相关论文
共 50 条
  • [1] PET SIMULATOR BASED ON MONTE-CARLO METHOD
    PANI, R
    PELLEGRINI, R
    RUBIO, M
    BANCI, M
    SCOPINARO, F
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 633 - 633
  • [2] Validation of a PET Monte-Carlo simulator with random events and dead time modeling
    Le Meunier, L
    Mathy, F
    Fagret, PD
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1108 - 1112
  • [3] Validation of a PET Monte-Carlo simulator with random events and dead time modeling
    Le Meunier, L
    Mathy, F
    Fagret, PD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1462 - 1468
  • [4] A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation
    Solevi, P.
    Oliver, J. F.
    Gillam, J. E.
    Bolle, E.
    Casella, C.
    Chesi, E.
    De Leo, R.
    Dissertori, G.
    Fanti, V.
    Heller, M.
    Lai, M.
    Lustermann, W.
    Nappi, E.
    Pauss, F.
    Rudge, A.
    Ruotsalainen, U.
    Schinzel, D.
    Schneider, T.
    Seguinot, J.
    Stapnes, S.
    Weilhammer, P.
    Tuna, U.
    Joram, C.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5495 - 5510
  • [5] Improved Monte-Carlo simulator of partial discharge
    VanBrunt, RJ
    vonGlahn, P
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 504 - 509
  • [6] Photopolymerizable hydrogels for implants: Monte-Carlo modeling and experimental in vitro validation
    Schmocker, Andreas
    Khoushabi, Azadeh
    Schizas, Constantin
    Bourban, Pierre-Etienne
    Pioletti, Dominique P.
    Moser, Christophe
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (03)
  • [7] NMOS PROCESS SIMULATOR USING MONTE-CARLO METHODS
    NAIDU, RV
    MICROELECTRONICS AND RELIABILITY, 1990, 30 (01): : 19 - 22
  • [8] Experimental validation of a rapid Monte Carlo based micro-CT simulator
    Colijn, AP
    Zbijewski, W
    Sasov, A
    Beekman, FJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18): : 4321 - 4333
  • [9] ANALYSIS OF THE PERFORMANCE OF A PET SCANNER THROUGH MONTE-CARLO SIMULATION AND EXPERIMENTAL COMPARISON
    ACCHIAPPATI, D
    CERULLO, N
    GUZZARDI, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 233 - 233
  • [10] Validation of a Monte-Carlo Markov Model for Schizophrenia
    Dragomir, Alice
    Angers, Jean-Francois
    Tarride, Jean-Eric
    Joober, Ridha
    Perreault, Sylvie
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2010, 19 : S153 - S154