Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
|
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [41] Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT
    Gong, X-Y
    Meyer, E.
    Yu, X-J
    Sun, J-H
    Sheng, L-P
    Huang, K-H
    Wu, R-Z
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)
  • [42] Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Pardis Ghafarian
    S. M. R. Aghamiri
    Mohammad R. Ay
    Arman Rahmim
    Thomas H. Schindler
    Osman Ratib
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 252 - 262
  • [43] Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV
    Queiroz, Polyane M.
    Santaella, Gustavo M.
    da Paz, Thais D. J.
    Freitas, Deborah Q.
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (03)
  • [44] Assessment of metal artefact reduction around dental titanium implants in cone beam CT
    Parsa, A.
    Ibrahim, N.
    Hassan, B.
    Syriopoulos, K.
    van der Stelt, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (07)
  • [45] Combination of dual-energy computed tomography and iterative metal artefact reduction to increase general quality of imaging for radiotherapy patients with high dense materials. Phantom study
    Pawalowski, Bartosz
    Panek, Rafal
    Szweda, Hubert
    Piotrowski, Tomasz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 92 - 99
  • [46] Metal artefact reduction in CT imaging of hip prostheses-an evaluation of commercial techniques provided by four vendors
    Andersson, K. M.
    Nowik, P.
    Persliden, J.
    Thunberg, P.
    Norrman, E.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052):
  • [47] Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Ghafarian, Pardis
    Aghamiri, S. M. R.
    Ay, Mohammad R.
    Rahmim, Arman
    Schindler, Thomas H.
    Ratib, Osman
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (02) : 252 - 262
  • [48] Frequency split metal artefact reduction in pelvic computed tomography
    Lell, M. M.
    Meyer, E.
    Schmid, M.
    Raupach, R.
    May, M. S.
    Uder, M.
    Kachelriess, M.
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2137 - 2145
  • [49] Effect of a saline flush technique for head and neck imaging in dual-energy CT: improvement of image quality and perivenous artefact reduction using virtual monochromatic imaging
    Washio, H.
    Ohira, S.
    Kanayama, N.
    Wada, K.
    Karino, T.
    Komiyama, R.
    Miyazaki, M.
    Teshima, T.
    CLINICAL RADIOLOGY, 2019, 74 (10) : 805 - 812
  • [50] A DISTANCE DRIVEN METHOD FOR METAL ARTEFACT REDUCTION IN COMPUTED TOMOGRAPHY
    Mouton, Andre
    Megherbi, Najla
    Van Slambrouck, Katrien
    Nuyts, Johan
    Breckon, Toby P.
    2013 20TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2013), 2013, : 2334 - 2338