Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
|
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [31] Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses
    Wellenberg, R. H. H.
    Boomsma, M. F.
    van Osch, J. A. C.
    Vlassenbroek, A.
    Milles, J.
    Edens, M. A.
    Streekstra, G. J.
    Slump, C. H.
    Maas, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 61 - 70
  • [32] Assessing the effect of CT Metal Artefact Reduction on PET quantification for lesions near a metal implant
    Michopoulou, S.
    Tossici-Bolt, L.
    Richards, M.
    Guy, M. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S720 - S720
  • [33] Application of Extended CT Scale and Metal Artefact Reduction Methods on Radiotherapy Planning
    Yucel, H.
    Biltekin, F.
    Ozyigit, G.
    Yazici, G.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S954 - S954
  • [34] An experimental survey of metal artefact reduction in computed tomography
    Mouton, Andre
    Megherbi, Najla
    Van Slambrouck, Katrien
    Nuyts, Johan
    Breckon, Toby P.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 193 - 226
  • [35] Metal artefact reduction for accurate tumour delineation in radiotherapy
    Kovacs, David Gergely
    Rechner, Laura A.
    Appelt, Ane L.
    Berthelsen, Anne K.
    Costa, Junia C.
    Friborg, Jeppe
    Persson, Gitte F.
    Bangsgaard, Jens Peter
    Specht, Lena
    Aznar, Marianne C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 126 (03) : 479 - 486
  • [36] An Investigation into Metal Artefact Reduction Approaches in CT Attenuation Correction for SPECT/CT and PET/CT
    Johnson, J. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S491 - S491
  • [37] Quantification of Metal Artifact Reduction of Dual-Energy CT: A Phantom Study
    Li, K.
    Leung, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3036 - 3036
  • [38] A study of metal artefact reduction for industrial X-ray CT system with limited radiation energy
    Yu, Wei
    Zeng, Li
    Yang, Xiangyu
    INSIGHT, 2014, 56 (02) : 69 - 74
  • [39] Complementary contrast media for metal artifact reduction in Dual-Energy CT
    Lambert, Jack W.
    Edic, Peter M.
    FitzGerald, Paul
    Torres, Andrew S.
    Yeh, Benjamin M.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [40] Dual-Energy CBCT Imaging for Metal Artifact Reduction and Contrast Enhancement
    Li, H.
    Giles, W.
    Ren, L.
    Bowsher, J.
    Yin, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 4017 - 4017