Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
|
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [1] Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software
    Young Han Lee
    Kwan Kyu Park
    Ho-Taek Song
    Sungjun Kim
    Jin-Suck Suh
    European Radiology, 2012, 22 : 1331 - 1340
  • [2] Visibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software
    Jeong, Jewon
    Kim, Hyun-joo
    Oh, Eunsun
    Cha, Jang Gyu
    Hwang, Jiyoung
    Hong, Seong Sook
    Chang, Yun Woo
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (05) : 634 - 641
  • [3] Evaluation of dual energy CT and iterative metal artefact reduction (iMAR) for artefact reduction in radiation therapy
    P. Lim
    J. Barber
    J. Sykes
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 1025 - 1032
  • [4] Evaluation of dual energy CT and iterative metal artefact reduction (iMAR) for artefact reduction in radiation therapy
    Lim, P.
    Barber, J.
    Sykes, J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1025 - 1032
  • [5] Dual-Energy Computed Tomography-How Accurate Is Gemstone Spectrum Imaging Metal Artefact Reduction? Its Application to Orthopedic Metal Implants
    Dabirrahmani, Dane
    Magnussen, John
    Appleyard, Richard Charles
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (06) : 925 - 935
  • [6] Motion Artefact Reduction in Dual-Energy Radiography
    Shunkov, Yu E.
    Kobylkin, I. S.
    Prokhorov, A., V
    Pozdnyakov, D., V
    Kasiuk, D. M.
    Nechaev, V. A.
    Alekseeva, O. M.
    Naumova, D., I
    Dabagov, A. R.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 55 (06): : 415 - 419
  • [7] Dual energy CT and iterative metal artefact reduction for accurate tumour delineation
    Kovacs, D.
    Rechner, L.
    Bangsgaard, J.
    Berthelsen, A.
    Costa, J.
    Friborg, J.
    Persson, G.
    Specht, L.
    Vogelius, I.
    Aznar, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S70 - S70
  • [8] Motion Artefact Reduction in Dual-Energy Radiography
    Yu. E. Shunkov
    I. S. Kobylkin
    A. V. Prokhorov
    D. V. Pozdnyakov
    D. M. Kasiuk
    V. A. Nechaev
    O. M. Alekseeva
    D. I. Naumova
    A. R. Dabagov
    Biomedical Engineering, 2022, 55 : 415 - 419
  • [9] Evaluation of the dental spectral cone beam CT for metal artefact reduction
    Zhu, Ling
    Chen, Yi
    Yang, Jie
    Tao, Xiaofeng
    Xi, Yan
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (02)
  • [10] Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation
    Yanwei Zeng
    Kai Deng
    Haitao Yang
    Yi Tan
    Jun Liu
    Daoying Geng
    Jun Zhang
    European Spine Journal, 2019, 28 : 1783 - 1792