Improving methods of chordal-sparing mitral valve replacement .3. Optimal direction for artificial chordae

被引:0
|
作者
Komeda, M
DeAnda, A
Glasson, JR
Daugthers, GT
Bolger, AF
Nikolic, SD
Ingels, NB
Miller, DC
机构
[1] STANFORD UNIV,SCH MED,FALK CARDIOVASC RES CTR,DEPT CARDIOVASC & THORAC SURG,STANFORD,CA 94305
[2] STANFORD UNIV,SCH MED,DIV CARDIOVASC MED,STANFORD,CA 94305
[3] PALO ALTO DVA MED CTR,PALO ALTO,CA
[4] PALO ALTO MED FDN,RES INST,DEPT CARDIOVASC PHYSIOL & BIOPHYS,PALO ALTO,CA 94301
来源
JOURNAL OF HEART VALVE DISEASE | 1996年 / 5卷 / 05期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: The optimal direction to preserve artificial chordae tendineae (CT) during mitral valve replacement (MVR) is not known, especially in regard to the response to inotropic stimulation which simulates exercise conditions. Methods: Using a non-distorting isovolumic balloon technique, we compared left ventricular (LV) systolic and diastolic mechanics in II dogs in a control state (no chordal sparing) and with four different methods of chordal preservation: posterior, anterior, oblique (anterior papillary muscle chordae directed anteriorly and others posteriorly, the direction which theoretically augments LV systolic twist), and counter-oblique (counter, chordae preserved in directions opposite to oblique). Results: Before dobutamine, Delta E(max) from the control was: 0.32 +/- 0.82, 0.10 +/- 0.43, 0.64 +/- 1.07, and 0.51 +/- 0.78 (anterior, posterior, oblique, and counter method, respectively). With dobutamine (3 mg/kg/min), Delta E(max) (mmHg/ml) was: 0.41 +/- 1.21, -0.13 +/- 0.75, 0.59 +/- 0.82*, and -0.34 +/- 0.71. Before dobutamine, Delta LV stiffness (S-d, mmHg/ml) was -0.01 +/- 0.09, -0.02 +/- 0.12, 0.02 +/- 0.10, and 0.01 +/- 0.12; with dobutamine it was 0.01 +/- 0.09, 0.00 +/- 0.15, 0.03 +/- 0.15, and -0.06 +/- 0.11. Similarly, before dobutamine Delta LV equilibrium volume (V-eq) eq was -1.2 +/- 3.8, -0.3 +/- 3.0, -0.7 +/- 2.7, and -0.2 +/- 3.5, whereas with dobutamine sigma(eq) was -0.1 +/- 1.1, -0.4 +/- 0.8, 0.6 +/- 1.7, and -0.4 +/- 1.1. (Mean +/- S.D.; *p = 0.005 posterior and counter by ANOVA; p = NS ( < 0.06) versus counter and posterior by ANOVA). Conclusions: The oblique method enhanced systolic LV function bath with and without dobutamine, while a tendency towards better diastolic LV function (V-eq) was observed with dobutamine. The anterior method was next best in preserving systolic function, both with and without dobutamine. LV diastolic function tended to deteriorate with dobutamine in the posterior group. Systolic function with the counter method deteriorated withe dobutamine. These results warrant further study in an ejecting model to investigate LV systolic and diastolic mechanics with the oblique method of CT preservation, including interactions with LV systolic twist and diastolic recoil.
引用
下载
收藏
页码:484 / 490
页数:7
相关论文
共 37 条
  • [21] Artificial mitral valve chordae replacement made simple - Invited commentary
    Acker, MA
    ANNALS OF THORACIC SURGERY, 2001, 71 (04): : 1378 - 1379
  • [22] Modified chordal sparing mitral valve replacement as effective technique for both stenotic and insufficient mitral valves
    Dzemeshkevich, Sergey L.
    Korolev, Sergey, V
    Gramovich, Vladimir V.
    Frolova, Yulia, V
    Lugovoy, Alexey N.
    Dombrovskaya, Anna, V
    Babaev, Maxim A.
    Zaklyazminskaya, Elena, V
    JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 63 (04): : 498 - 506
  • [23] Improving methods of chordal sparing mitral valve replacement .1. A new, non-distorting isovolumic balloon preparation for the left ventricle with intact mitral subvalvular apparatus
    Komeda, M
    Bolger, AF
    DeAnda, A
    Tomizawa, Y
    Ingels, NB
    Miller, C
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (04): : 376 - 382
  • [24] Exploring better methods to preserve the chordae tendineae during mitral valve replacement
    Komeda, M
    DeAnda, A
    Glasson, JR
    Bolger, AF
    Tomizawa, Y
    Daughters, GT
    Tye, TL
    Ingels, NB
    Miller, DC
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1652 - 1657
  • [25] Mitral valve repair with artificial chordae replacement in children: a single-center experience
    Dun, Yaojun
    Xing, Jiayi
    Zhao, Dong
    Su, Wenjun
    Luo, Guohua
    Yang, Keming
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2021, 69 (10) : 1383 - 1391
  • [26] Mitral valve repair with artificial chordae replacement in children: a single-center experience
    Yaojun Dun
    Jiayi Xing
    Dong Zhao
    Wenjun Su
    Guohua Luo
    Keming Yang
    General Thoracic and Cardiovascular Surgery, 2021, 69 : 1383 - 1391
  • [27] MITRAL-VALVE REPAIR VERSUS CHORDAE-SPARING MITRAL-VALVE REPLACEMENT IN DOGS WITH CONTRACTILE DYSFUNCTION DUE TO EXPERIMENTAL MITRAL REGURGITATION
    NAGATSU, M
    ISHIHARA, K
    DEFREYTE, G
    TANAKA, R
    ZILE, M
    CARABELLO, B
    CIRCULATION, 1992, 86 (04) : 699 - 699
  • [28] Exploring better methods to preserve the chordae tendineae during mitral valve replacement - Discussion
    Lillehei, CW
    Komeda, M
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1658 - 1658
  • [29] EXPERIMENTAL EVALUATION OF DIFFERENT CHORDAL PRESERVATION METHODS DURING MITRAL-VALVE REPLACEMENT
    MOON, MR
    DEANDA, A
    DAUGHTERS, GT
    INGELS, NB
    MILLER, DC
    ANNALS OF THORACIC SURGERY, 1994, 58 (04): : 931 - 944
  • [30] Randomized trial of partial versus complete chordal preservation methods of mitral valve replacement - A preliminary report
    Yun, KL
    Sintek, CF
    Miller, DC
    Schuyler, GT
    Fletcher, AD
    Pfeffer, TA
    Kochamba, GS
    Khonsari, S
    Zile, MR
    CIRCULATION, 1999, 100 (19) : 90 - 94