Exploring better methods to preserve the chordae tendineae during mitral valve replacement

被引:14
|
作者
Komeda, M
DeAnda, A
Glasson, JR
Bolger, AF
Tomizawa, Y
Daughters, GT
Tye, TL
Ingels, NB
Miller, DC
机构
[1] STANFORD UNIV,SCH MED,DEPT CARDIOVASC & THORAC SURG,FALK CARDIOVASC RES CTR,STANFORD,CA 94305
[2] STANFORD UNIV,SCH MED,DIV CARDIOVASC MED,STANFORD,CA 94305
[3] VET AFFAIRS MED CTR,PALO ALTO,CA 94304
[4] PALO ALTO MED FDN,RES INST,DEPT CARDIOVASC PHYSIOL & BIOPHYS,PALO ALTO,CA 94301
来源
ANNALS OF THORACIC SURGERY | 1995年 / 60卷 / 06期
关键词
D O I
10.1016/0003-4975(95)00837-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. It is not known how best to resuspend the mitral chordae tendineae during mitral valve replacement to optimize postoperative left ventricular (LV) systolic and diastolic function. Methods. Six different techniques to preserve the chordae during mitral valve replacement were compared in 12 dogs using a nondistorting isovolumic technique: conventional, all chordae severed; anterior, all chordae preserved anteriorly; partial, anterior papillary muscle chordae preserved anteriorly; posterior, all chordae preserved posteriorly; oblique, anterior papillary muscle chordae directed anteriorly and posterior papillary muscle chordae posteriorly; and counter, opposite of oblique chordal direction. Control measurements (no chordal tension) were recorded between each experimental condition. Results. The oblique method tended to have the best LV systolic function versus the conventional method (E(max) = 4.0 +/- 1.8 versus 3.3 +/- 1.2 mm Hg/mL [mean +/- standard deviation]; p = 0.08 by repeated-measures analysis of variance; physiologic intercept E(es100) = 20.3 +/- 8.6 mL [p < 0.05 versus control]), with no major change in LV diastolic stiffness. The posterior method had a lower E(max) (3.3 +/- 1.2 mm Hg/mL) than the oblique method, but a similar E(es100) (20.8 +/- 8.1 mL; p < 0.05 versus control) and the best diastolic LV performance (LV diastolic stiffness = 0.46 +/- 0.23 mm Hg/mL). The counter method also had good systolic function (E(max) = 3.8 +/- 1.2 mm Hg/mL; E(es100) = 19.7 +/- 7.5 mL; p < 0.05 versus control), but had less favorable diastolic properties (0.65 +/- 0.37 mm Hg/mL; p < 0.05 by repeated-measures analysis of variance versus posterior). Conclusions. In this isovolumic preparation in normal canine hearts, the oblique method of chordal resuspension was associated with the best LV systolic function, whereas the counter technique impaired LV diastolic function. These preliminary results warrant further study in ejecting and failing hearts to determine conclusively which chordal orientation best preserves LV performance after mitral valve replacement.
引用
收藏
页码:1652 / 1657
页数:6
相关论文
共 50 条
  • [1] Exploring better methods to preserve the chordae tendineae during mitral valve replacement - Discussion
    Lillehei, CW
    Komeda, M
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1658 - 1658
  • [2] Results of represervation of the chordae tendineae during redo mitral valve replacement
    Rao, V
    Komeda, M
    Weisel, RD
    Ivanov, J
    Ikonomidis, JS
    Shirai, T
    David, TE
    ANNALS OF THORACIC SURGERY, 1996, 62 (01): : 179 - 183
  • [3] PRESERVATION OF ANTERIOR LEAFLET CHORDAE TENDINEAE DURING MITRAL-VALVE REPLACEMENT
    ROSE, EA
    OZ, MC
    ANNALS OF THORACIC SURGERY, 1994, 57 (03): : 768 - 769
  • [4] REPLACEMENT OF RUPTURED CHORDAE TENDINEAE OF MITRAL-VALVE WITH AUTOLOGOUS PERICARDIAL CHORDAE
    RITTENHOUSE, EA
    DAVIS, CC
    WOOD, SJ
    SAUVAGE, LR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1978, 75 (06): : 870 - 876
  • [5] MITRAL VALVE REPLACEMENT WITH PRESERVATION OF PAPILLARY MUSCLES + CHORDAE TENDINEAE
    LILLEHEI, CW
    LEVY, MJ
    BONNABEAU, RC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1964, 47 (04): : 532 - &
  • [6] MITRAL VALVE REPLACEMENT WITH PRESERVATION OF PAPILLARY MUSCLES + CHORDAE TENDINEAE
    LILLEHEI, CW
    BONNABEAU, RC
    LEVY, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1964, 13 (01): : 117 - &
  • [7] Chordae tendineae mimicking vegetation after mitral valve replacement
    Malaterre, HR
    Sunda, M
    ANNALS OF THORACIC SURGERY, 1996, 62 (03): : 944 - 945
  • [8] RUPTURE OF CHORDAE TENDINEAE MITRAL VALVE
    PALMER, RS
    WYMAN, SM
    MALLORY, TB
    NEW ENGLAND JOURNAL OF MEDICINE, 1950, 243 (16): : 611 - 615
  • [9] VALVE REPLACEMENT FOR RUPTURED CHORDAE TENDINEAE OF MITRAL VALVE - EXPERIENCE WITH 12 PATIENTS
    SCHACHNER, A
    LEVY, MJ
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1971, 7 (10): : 1146 - +
  • [10] SCLEROSIS OF THE CHORDAE TENDINEAE OF THE MITRAL VALVE
    SOKOLOFF, L
    ELSTER, SK
    RIGHTHAND, N
    CIRCULATION, 1950, 1 (04) : 782 - 791