Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantation

被引:17
|
作者
Morton, AC [1 ]
Arnold, ND [1 ]
Crossman, DC [1 ]
Gunn, J [1 ]
机构
[1] Univ Sheffield, No Gen Hosp, Div Clin Sci, Cardiovasc Res Grp, Sheffield S5 7AU, S Yorkshire, England
关键词
D O I
10.1136/hrt.2003.015305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the response of very small coronary arteries to stent deployment and balloon angioplasty. Setting: Normal porcine coronary arteries. Methods: 24 pigs underwent intervention to two main coronary arteries, in segments 2.0 mm in diameter, with balloons whose diameter was 2.5 mm at standard pressure. Twelve arteries received a BiodivYsio small vessel (SV) stent; 12 an NIR SV stent; 12 standard BiodivYsio stent, and 12 balloon only. The arteries were harvested at 28 days, fixed, embedded in plastic, and cut and ground in cross section. The injury score and histomorphometry were assessed. Results: The BiodivYsio SV stent was associated with 20% less injury ( p = 0.16), a 30% larger lumen ( p = 0.13), and a 25% smaller neointima ( p = 0.03) than the NIR SV stent, despite identical oversize. The standard BiodivYsio stent exhibited less recoil but 29% greater injury ( p = 0.01), 59% more neointima ( p = 0.00), and 18% less lumen ( p = 0.27) than the BiodivYsio SV. Of all interventions, balloon only was associated with little injury, little neointima, major vessel shrinkage, and the largest lumen. Conclusion: Despite uniform oversize dilatation, both injury and response varied widely in very small porcine coronary arteries, depending on whether a stent or balloon was used, the stent design, and the number and/or thickness of struts. The response to different stent designs is considerable and is related to the degree of injury.
引用
收藏
页码:324 / 327
页数:4
相关论文
共 50 条
  • [31] Efficacy of coronary stenting versus balloon angioplasty in small corollary arteries
    Savage, MP
    Fischman, DL
    Rake, R
    Leon, MB
    Schatz, RA
    Penn, I
    Nobuyoshi, M
    Moses, J
    Hirshfeld, J
    Heuser, R
    Baim, D
    Cleman, M
    Brinker, J
    Gebhardt, S
    Goldberg, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 307 - 311
  • [32] Should we stent small coronary vessels? Comparison with balloon angioplasty
    FernandezOrtiz, A
    PerezVizcayno, MJ
    Goicolea, J
    Alfonso, F
    Banuelos, C
    Hernandez, R
    Escaned, J
    Delgado, A
    Macaya, C
    CIRCULATION, 1997, 96 (08) : 1521 - 1521
  • [33] Dose Response to Paclitaxel-Coated Balloon Catheters in the Porcine Coronary Overstretch and Stent Implantation Model
    Kelsch, Bettina
    Scheller, Bruno
    Biedermann, Melanie
    Clever, Yvonne P.
    Schaffner, Silvio
    Mahnkopf, Dirk
    Speck, Ulrich
    Cremers, Bodo
    INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 255 - 263
  • [34] Stent placement to prevent restenosis after angioplasty in small coronary arteries
    Doucet, S
    Schalij, MJ
    Vrolix, MCM
    Hilton, D
    Chenu, P
    de Bruyne, B
    Udayachalerm, W
    Seth, A
    Bilodeau, L
    Reiber, JHC
    Harel, F
    Lespérance, J
    CIRCULATION, 2001, 104 (17) : 2029 - 2033
  • [35] Neointimal response following rotational atherectomy compared to balloon angioplasty in a porcine model of coronary in-stent restenosis
    McKenna, CJ
    Wilson, SH
    Camrud, AR
    Berger, PB
    Holmes, DR
    Schwartz, RS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 45 (03): : 332 - 336
  • [36] Comparison of serial changes in coronary arteries after Palmaz-Schatz stent implantation and balloon angioplasty: A histopathological and immunohistochemical study
    Inoue, K
    Nakamura, N
    Nagamatsu, T
    Imanaka-Yoshida, K
    Matsuura, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 140A - 140A
  • [37] Promising efficacy of primary gradual and prolonged balloon angioplasty in small coronary arteries: A randomized comparison with cutting balloon angioplasty and conventional balloon angioplasty
    Umeda, H
    Iwase, M
    Kanda, H
    Izawa, H
    Nagata, K
    Ishiki, R
    Sawada, K
    Murohara, T
    Yokota, M
    AMERICAN HEART JOURNAL, 2004, 147 (01)
  • [38] RESTENOSIS AFTER BALLOON ANGIOPLASTY - A PRACTICAL PROLIFERATIVE MODEL IN PORCINE CORONARY-ARTERIES
    SCHWARTZ, RS
    MURPHY, JG
    EDWARDS, WD
    CAMRUD, AR
    VLIETSTRA, RE
    HOLMES, DR
    CIRCULATION, 1990, 82 (06) : 2190 - 2200
  • [39] Prolonged thrombin inhibition reduces restenosis after balloon angioplasty in porcine coronary arteries
    Gallo, R
    Padurean, A
    Toschi, V
    Bichler, J
    Fallon, JT
    Chesebro, JH
    Fuster, V
    Badimon, JJ
    CIRCULATION, 1998, 97 (06) : 581 - 588
  • [40] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08): : 489 - 495