Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantation

被引:17
|
作者
Morton, AC [1 ]
Arnold, ND [1 ]
Crossman, DC [1 ]
Gunn, J [1 ]
机构
[1] Univ Sheffield, No Gen Hosp, Div Clin Sci, Cardiovasc Res Grp, Sheffield S5 7AU, S Yorkshire, England
关键词
D O I
10.1136/hrt.2003.015305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the response of very small coronary arteries to stent deployment and balloon angioplasty. Setting: Normal porcine coronary arteries. Methods: 24 pigs underwent intervention to two main coronary arteries, in segments 2.0 mm in diameter, with balloons whose diameter was 2.5 mm at standard pressure. Twelve arteries received a BiodivYsio small vessel (SV) stent; 12 an NIR SV stent; 12 standard BiodivYsio stent, and 12 balloon only. The arteries were harvested at 28 days, fixed, embedded in plastic, and cut and ground in cross section. The injury score and histomorphometry were assessed. Results: The BiodivYsio SV stent was associated with 20% less injury ( p = 0.16), a 30% larger lumen ( p = 0.13), and a 25% smaller neointima ( p = 0.03) than the NIR SV stent, despite identical oversize. The standard BiodivYsio stent exhibited less recoil but 29% greater injury ( p = 0.01), 59% more neointima ( p = 0.00), and 18% less lumen ( p = 0.27) than the BiodivYsio SV. Of all interventions, balloon only was associated with little injury, little neointima, major vessel shrinkage, and the largest lumen. Conclusion: Despite uniform oversize dilatation, both injury and response varied widely in very small porcine coronary arteries, depending on whether a stent or balloon was used, the stent design, and the number and/or thickness of struts. The response to different stent designs is considerable and is related to the degree of injury.
引用
收藏
页码:324 / 327
页数:4
相关论文
共 50 条
  • [21] CORONARY ANGIOPLASTY WITH STENT IMPLANTATION
    TEBBE, U
    SCHATZ, RA
    SCHOLZ, KH
    BRUNE, S
    SAUER, G
    KREUZER, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1990, 115 (27) : 1054 - 1058
  • [22] Predictors of in-stent restenosis after stent implantation using 2.5-mm stents in small coronary arteries
    Miyazawa, A
    Iijima, R
    Ikari, Y
    Hara, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 205L - 205L
  • [23] Very Late Vascular Response After Bare Metal Stent Implantation in Human Coronary Arteries
    Inoue, Katsumi
    Imai, Masao
    Yamaji, Kyohei
    Ando, Kenji
    Nobuyoshi, Masakiyo
    Kimura, Takeshi
    CIRCULATION, 2014, 130
  • [24] Vascular endothelial growth factor in porcine coronary arteries following balloon angioplasty
    Hausner, EA
    Orsini, JA
    Foster, LL
    Modzelewski, TC
    Merrill, JJ
    Perkowski, SZ
    Slee, A
    JOURNAL OF INVESTIGATIVE SURGERY, 1999, 12 (01) : 15 - 23
  • [25] Extracellular Matrix Remodelling in Porcine Coronary Arteries Upon Stent Implantation
    Suna, Gonca
    Wojakowski, Wojtek
    Barallobre-Barreiro, Javier
    Yin, Xiaoke
    White, Steve J.
    Milewski, Krzysztof P.
    Gasior, P.
    Buszman, Piotr P.
    Buszman, Pawel E.
    Hill, Jonathan M.
    Mayr, Manuel
    CIRCULATION, 2015, 132
  • [26] Restitution of a tubular lumen after stent implantation in porcine coronary arteries
    Morton, AC
    Narracott, A
    Chan, K
    Arnold, N
    Crossman, DC
    Gunn, J
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 208L - 208L
  • [27] Self-expanding coronary Stent (radius) implantation with cutting balloon angioplasty
    Lee, SH
    Choi, SH
    Ko, YG
    Choi, DH
    Jang, YS
    Shim, WH
    CARDIOLOGY, 2005, 103 (03) : 123 - 127
  • [28] A comparison of stent designs in small diameter porcine coronary arteries
    Carter, AJ
    Scott, D
    Bailey, L
    Kim, D
    Devries, J
    Jones, R
    Virmani, R
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TCT5 - TCT5
  • [29] A randomized comparison of balloon angioplasty and stent implantation in the percutaneous treatment of coronary bifurcations
    Dens, J
    Dubois, C
    Vermeersch, P
    Coussement, P
    Vrolix, M
    Janssens, L
    Desmet, W
    Piessens, J
    ACTA CARDIOLOGICA, 2005, 60 (04) : 379 - 385
  • [30] Comparative analysis of stent placement versus balloon angioplasty in small coronary arteries with long narrowings (The Intracoronary Angioplasty for Restenosis Reduction in Small Arteries [ISAR-SMART] trial)
    Hausleiter, J
    Kastrati, A
    Mehilli, J
    Dotzer, F
    Schühlen, H
    Dirschinger, J
    Schömig, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01): : 58 - +