Effects of Feedback on Chest Compression Quality: A Randomized Simulation Study

被引:38
|
作者
Wagner, Michael [1 ,3 ]
Bibl, Katharina [1 ]
Hrdliczka, Emilie [1 ]
Steinbauer, Philipp [1 ]
Stiller, Maria [1 ]
Groepel, Peter [4 ]
Goeral, Katharina [1 ]
Salzer-Muhar, Ulrike [2 ]
Berger, Angelika [1 ]
Schmoelzer, Georg M. [3 ,5 ]
Olischar, Monika [1 ]
机构
[1] Med Univ Vienna, Div Neonatol Pediat Intens Care & Neuropediat, Dept Pediat & Adolescent Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Pediat Cardiol, Dept Pediat & Adolescent Med, Vienna, Austria
[3] Royal Alexandra Hosp, Neonatal Res Unit, Ctr Studies Asphyxia & Resuscitat, Alberta Hlth Serv, Edmonton, AB, Canada
[4] Univ Vienna, Dept Appl Psychol Work Educ & Econ, Vienna, Austria
[5] Univ Alberta, Dept Pediat, Div Neonatol, Edmonton, AB, Canada
关键词
HOSPITAL CARDIAC-ARREST; IMPROVING CARDIOPULMONARY-RESUSCITATION; AUDIOVISUAL FEEDBACK; CPR FEEDBACK; OBJECTIVE FEEDBACK; MANNEQUIN CPR; PERFORMANCE; DEVICE; IMPACT; GUIDELINES;
D O I
10.1542/peds.2018-2441
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVES: Our aim for this study was to test whether visual and verbal feedback compared with instructor-led feedback improve the quality of pediatric cardiopulmonary resuscitation (CPR). METHODS: There were 653 third-year medical students randomly assigned to practice pediatric CPR on 1 of 2 manikins (infant and adolescent; n = 344 and n = 309, respectively). They were further randomly assigned to 1 of 3 feedback groups: The instructor feedback (IF) group (n = 225) received traditional, instructor-led feedback without any additional feedback device. The device feedback (DF) group (n = 223) received real-time visual feedback from a feedback device. The instructor and device feedback (IDF) group (n = 205) received verbal feedback from an instructor who continuously reviewed the trainees' performance using the feedback device. After the training, participants' CPR performance was assessed on the same manikin while no feedback was being provided. RESULTS: For the primary outcome of total compression score, participants in the DF and IDF groups performed similarly, with both groups showing scores significantly (P < .001) better than those of the IF group. The same findings held for correct hand position and the proportion of complete release. For compression rate, the DF group was at the higher end of the guideline for 100 to 120 chest compressions per minute compared with the IF and IDF groups (both P < .001). No effect of feedback on compression depth was found. CONCLUSIONS: Chest compression performance significantly improved with both visual and verbal feedback compared with instructor-led feedback. Feedback devices should be implemented during pediatric resuscitation training to improve resuscitation performance.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Implementation of Chest Compression Feedback Technology to Improve the Quality of Cardiopulmonary Resuscitation in the Emergency Department: A Quality Initiative Test-of-change Study
    Pritchard, Jodie
    Roberge, Jillian
    Bacani, Joseph
    Welsford, Michelle
    Mondoux, Shawn
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (08)
  • [42] Effectiveness of chest compression feedback during cardiopulmonary resuscitation in lateral tilted and semirecumbent positions: a randomised controlled simulation study
    Song, Y.
    Oh, J.
    Chee, Y.
    Cho, Y.
    Lee, S.
    Lim, T. H.
    ANAESTHESIA, 2015, 70 (11) : 1235 - 1241
  • [43] Long-term benefits of chest compression-only cardiopulmonary resuscitation training using real-time visual feedback manikins: a randomized simulation study
    Jang, Tae Chang
    Ryoo, Hyun Wook
    Moon, Sungbae
    Ahn, Jae Yun
    Lee, Dong Eun
    Lee, Won Kee
    Kwak, Sang Gyu
    Kim, Jung Ho
    CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2020, 7 (03): : 206 - 212
  • [44] The Impact of Backboard Placement on Chest Compression Quality: A Mannequin Study
    Sanri, Erkman
    Karacabey, Sinan
    PREHOSPITAL AND DISASTER MEDICINE, 2019, 34 (02) : 182 - 187
  • [45] Comparison of Effects of Different Hand Positions During Chest Compression: A Randomized, Controlled, Crossover Mannequin Study
    Fei, Han
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):
  • [46] Application of current guidelines for chest compression depth on different surfaces and using feedback devices: a randomized cross-over study
    Schober, P.
    Krage, R.
    Lagerburg, V.
    Van Groeningen, D.
    Loer, S. A.
    Schwarte, L. A.
    MINERVA ANESTESIOLOGICA, 2014, 80 (04) : 429 - 435
  • [47] Chest Diameter Measurement in Pediatric Patients for Chest Compression Feedback Calibration
    Ruiz de Gauna, Sofia
    Gonzalez-Otero, Digna M.
    Ruiz, Jesus
    de Nigris, Stefano
    Saiz, Purificacion
    Gutierrez, J. J.
    Russe, James K.
    De Momi, Elena
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 69 - 72
  • [48] Impact of Postshock Transcutaneous Pacing on Chest Compression Quality during Resuscitation: A Simulation-Based Pilot Study
    Telec, Wojciech
    Klosiewicz, Tomasz
    Zalewski, Radoslaw
    Zukowska-Karolak, Julia
    Baszko, Artur
    Puslecki, Mateusz
    EMERGENCY MEDICINE INTERNATIONAL, 2021, 2021
  • [49] Effect of Audiovisual Feedback Device Type on Prehospital Chest Compression Quality During Prehospital Resuscitation
    Lee, Stephen Gyung Won G.
    Kim, Tae Han H.
    Song, Kyoung J.
    Park, Jeong Ho
    Kim, Ki Hong
    Choi, Yeongho
    Kim, Minwoo
    Hong, Kijeong
    CIRCULATION, 2023, 148
  • [50] Cardiopulmonary resuscitation feedback improves the quality of chest compression provided by hospital health care professionals
    Pozner, Charles N.
    Almozlino, Adam
    Elmer, Jonathan
    Poole, Stephen
    McNamara, De'Ann
    Barash, David
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (06): : 618 - 625