Effects of Feedback on Chest Compression Quality: A Randomized Simulation Study

被引:38
|
作者
Wagner, Michael [1 ,3 ]
Bibl, Katharina [1 ]
Hrdliczka, Emilie [1 ]
Steinbauer, Philipp [1 ]
Stiller, Maria [1 ]
Groepel, Peter [4 ]
Goeral, Katharina [1 ]
Salzer-Muhar, Ulrike [2 ]
Berger, Angelika [1 ]
Schmoelzer, Georg M. [3 ,5 ]
Olischar, Monika [1 ]
机构
[1] Med Univ Vienna, Div Neonatol Pediat Intens Care & Neuropediat, Dept Pediat & Adolescent Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Pediat Cardiol, Dept Pediat & Adolescent Med, Vienna, Austria
[3] Royal Alexandra Hosp, Neonatal Res Unit, Ctr Studies Asphyxia & Resuscitat, Alberta Hlth Serv, Edmonton, AB, Canada
[4] Univ Vienna, Dept Appl Psychol Work Educ & Econ, Vienna, Austria
[5] Univ Alberta, Dept Pediat, Div Neonatol, Edmonton, AB, Canada
关键词
HOSPITAL CARDIAC-ARREST; IMPROVING CARDIOPULMONARY-RESUSCITATION; AUDIOVISUAL FEEDBACK; CPR FEEDBACK; OBJECTIVE FEEDBACK; MANNEQUIN CPR; PERFORMANCE; DEVICE; IMPACT; GUIDELINES;
D O I
10.1542/peds.2018-2441
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVES: Our aim for this study was to test whether visual and verbal feedback compared with instructor-led feedback improve the quality of pediatric cardiopulmonary resuscitation (CPR). METHODS: There were 653 third-year medical students randomly assigned to practice pediatric CPR on 1 of 2 manikins (infant and adolescent; n = 344 and n = 309, respectively). They were further randomly assigned to 1 of 3 feedback groups: The instructor feedback (IF) group (n = 225) received traditional, instructor-led feedback without any additional feedback device. The device feedback (DF) group (n = 223) received real-time visual feedback from a feedback device. The instructor and device feedback (IDF) group (n = 205) received verbal feedback from an instructor who continuously reviewed the trainees' performance using the feedback device. After the training, participants' CPR performance was assessed on the same manikin while no feedback was being provided. RESULTS: For the primary outcome of total compression score, participants in the DF and IDF groups performed similarly, with both groups showing scores significantly (P < .001) better than those of the IF group. The same findings held for correct hand position and the proportion of complete release. For compression rate, the DF group was at the higher end of the guideline for 100 to 120 chest compressions per minute compared with the IF and IDF groups (both P < .001). No effect of feedback on compression depth was found. CONCLUSIONS: Chest compression performance significantly improved with both visual and verbal feedback compared with instructor-led feedback. Feedback devices should be implemented during pediatric resuscitation training to improve resuscitation performance.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Comparison of chest compression interruption times across 2 automated devices: a randomized, crossover simulation study
    Estock, Jamie L.
    Curinga, Holly K.
    Li, Airan
    Grieve, Lorin B.
    Brackney, Christopher R.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (01): : 57 - 62
  • [32] Smartwatch feedback device for high-quality chest compressions by a single rescuer during infant cardiac arrest: a randomized, controlled simulation study
    Lee, Juncheol
    Song, Yeongtak
    Oh, Jaehoon
    Chee, Youngjoon
    Ahn, Chiwon
    Shin, Hyungoo
    Kang, Hyunggoo
    Lim, Tae Ho
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2019, 26 (04) : 266 - 271
  • [33] Does accelerometer feedback on high-quality chest compression improve survival rate? An in-hospital cardiac arrest simulation
    Jung, Min Hee
    Oh, Je Hyeok
    Kim, Chan Woong
    Kim, Sung Eun
    Hoon, Dong
    Chang, Wen Joen
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (08): : 993 - 997
  • [34] Effects of Chest Compression on Ventilation Quality during Cardiopulmonary Resuscitation
    Ding, Bozhi
    Pan, Chang
    Pang, Jiaojiao
    Wang, Jiali
    Li, Ke
    Xu, Feng
    Chen, Yuguo
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [35] Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study
    Lee, Seungjae
    Song, Yeongtak
    Lee, Jongshill
    Oh, Jaehoon
    Lim, Tae Ho
    Ahn, Chiwon
    Kim, In Young
    BIOSENSORS-BASEL, 2021, 11 (02):
  • [36] Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study
    Lee S.
    Song Y.
    Lee J.
    Oh J.
    Lim T.H.
    Ahn C.
    Kim I.Y.
    Biosensors, 2021, 11 (02):
  • [37] A randomised control trial of prompt and feedback devices and their impact on quality of chest compressions-A simulation study
    Yeung, Joyce
    Davies, Robin
    Gao, Fang
    Perkins, Gavin D.
    RESUSCITATION, 2014, 85 (04) : 553 - 559
  • [38] Chest Compression Quality in a Newborn Manikin: A Randomized Crossover Trial (August 2016)
    Solevag, Anne Lee
    Cheung, Po-Yin
    Li, Elliott
    Xue, Sarah Zhenchun
    O'Reilly, Megan
    Fu, Bo
    Zheng, Bin
    Schmolzer, Georg
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
  • [39] Does the use of cardiopulmonary resuscitation feedback devices improve the quality of chest compressions performed by doctors? A prospective, randomized, cross-over simulation study
    Majer, Jolanta
    Jaguszewski, Milosz J.
    Frass, Michael
    Leskiewicz, Marcin
    Smereka, Jacek
    Ladny, Jerzy R.
    Robak, Oliver
    Szarpak, Lukasz
    CARDIOLOGY JOURNAL, 2019, 26 (05) : 529 - 535
  • [40] The effect of distraction by dual work on a CPR practitioner's efficiency in chest compression: A randomized controlled simulation study
    Lee, Kwangchun
    Kim, Min Joung
    Park, Junseok
    Park, Joon Min
    Kim, Kyung Hwan
    Shin, Dong Wun
    Kim, Hoon
    Jeon, Woochan
    Kim, Hyunjong
    MEDICINE, 2017, 96 (43)