Effects of Feedback on Chest Compression Quality: A Randomized Simulation Study

被引:38
|
作者
Wagner, Michael [1 ,3 ]
Bibl, Katharina [1 ]
Hrdliczka, Emilie [1 ]
Steinbauer, Philipp [1 ]
Stiller, Maria [1 ]
Groepel, Peter [4 ]
Goeral, Katharina [1 ]
Salzer-Muhar, Ulrike [2 ]
Berger, Angelika [1 ]
Schmoelzer, Georg M. [3 ,5 ]
Olischar, Monika [1 ]
机构
[1] Med Univ Vienna, Div Neonatol Pediat Intens Care & Neuropediat, Dept Pediat & Adolescent Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Pediat Cardiol, Dept Pediat & Adolescent Med, Vienna, Austria
[3] Royal Alexandra Hosp, Neonatal Res Unit, Ctr Studies Asphyxia & Resuscitat, Alberta Hlth Serv, Edmonton, AB, Canada
[4] Univ Vienna, Dept Appl Psychol Work Educ & Econ, Vienna, Austria
[5] Univ Alberta, Dept Pediat, Div Neonatol, Edmonton, AB, Canada
关键词
HOSPITAL CARDIAC-ARREST; IMPROVING CARDIOPULMONARY-RESUSCITATION; AUDIOVISUAL FEEDBACK; CPR FEEDBACK; OBJECTIVE FEEDBACK; MANNEQUIN CPR; PERFORMANCE; DEVICE; IMPACT; GUIDELINES;
D O I
10.1542/peds.2018-2441
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVES: Our aim for this study was to test whether visual and verbal feedback compared with instructor-led feedback improve the quality of pediatric cardiopulmonary resuscitation (CPR). METHODS: There were 653 third-year medical students randomly assigned to practice pediatric CPR on 1 of 2 manikins (infant and adolescent; n = 344 and n = 309, respectively). They were further randomly assigned to 1 of 3 feedback groups: The instructor feedback (IF) group (n = 225) received traditional, instructor-led feedback without any additional feedback device. The device feedback (DF) group (n = 223) received real-time visual feedback from a feedback device. The instructor and device feedback (IDF) group (n = 205) received verbal feedback from an instructor who continuously reviewed the trainees' performance using the feedback device. After the training, participants' CPR performance was assessed on the same manikin while no feedback was being provided. RESULTS: For the primary outcome of total compression score, participants in the DF and IDF groups performed similarly, with both groups showing scores significantly (P < .001) better than those of the IF group. The same findings held for correct hand position and the proportion of complete release. For compression rate, the DF group was at the higher end of the guideline for 100 to 120 chest compressions per minute compared with the IF and IDF groups (both P < .001). No effect of feedback on compression depth was found. CONCLUSIONS: Chest compression performance significantly improved with both visual and verbal feedback compared with instructor-led feedback. Feedback devices should be implemented during pediatric resuscitation training to improve resuscitation performance.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Improvement in chest compression quality using a feedback device (CPRmeter): a simulation randomized crossover study
    Buleon, Clement
    Parienti, Jean-Jacques
    Halbout, Laurent
    Arrot, Xavier
    Regent, Helene De Facq
    Chelarescu, Dan
    Fellahi, Jean-Luc
    Gerard, Jean-Louis
    Hanouz, Jean-Luc
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (10): : 1457 - 1461
  • [2] A Randomized Control Trial of Cardiopulmonary Feedback Devices and Their Impact on Infant Chest Compression Quality A Simulation Study
    Austin, Andrea L.
    Spalding, Carmen N.
    Landa, Katrina N.
    Myer, Brian R.
    Cure, Donald
    Smith, Jason E.
    Platt, Gerald
    King, Heather C.
    PEDIATRIC EMERGENCY CARE, 2020, 36 (02) : E79 - E84
  • [3] Efficacy of a Simplified Feedback Trainer for High-Quality Chest Compression Training: A Randomized Controlled Simulation Study
    Meng, Xiao-yan
    You, Jia
    Dai, Li-li
    Yin, Xiao-dong
    Xu, Jian-an
    Wang, Jia-feng
    FRONTIERS IN PUBLIC HEALTH, 2021, 9
  • [4] Impact of a CPRMeter feedback device on chest compression quality performer by nurses: A randomized crossover study
    Konski, Roman
    Cieciel, Michal
    Madziala, Marcin
    Madziala, Agnieszka
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (12): : 2321 - 2322
  • [5] Quality retention of chest compression after repetitive practices with or without feedback devices: A randomized manikin study
    Zhou, Xian-Long
    Wang, Jing
    Jin, Xiao-Qing
    Zhao, Yan
    Liu, Rui-Ling
    Jiang, Cheng
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2020, 38 (01): : 73 - 78
  • [6] Impact of a feedback device on chest compression quality during extended manikin CPR: a randomized crossover study
    Buleon, Clement
    Delaunay, Julie
    Parienti, Jean-Jacques
    Halbout, Laurent
    Arrot, Xavier
    Gerard, Jean-Louis
    Hanouz, Jean-Luc
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1754 - 1760
  • [7] A Novel Method of Newborn Chest Compression: A Randomized Crossover Simulation Study
    Smereka, Jacek
    Szarpak, Lukasz
    Ladny, Jerzy R.
    Rodriguez-Nunez, Antonio
    Ruetzler, Kurt
    FRONTIERS IN PEDIATRICS, 2018, 6
  • [8] Effectiveness of real-time chest compression feedback devices for individuals experienced in cardiopulmonary resuscitation: a randomized controlled simulation study
    Won, Moonho
    Kim, Jae Hwan
    Ahn, Chiwon
    Lee, Sae Youn
    Oh, Yoonseok
    SIGNA VITAE, 2024, 20 (10) : 1 - 8
  • [9] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Leo, Wen Zhe
    Chua, Damien
    Tan, Hui Cheng
    Ho, Vui Kian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [10] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Wen Zhe Leo
    Damien Chua
    Hui Cheng Tan
    Vui Kian Ho
    Scientific Reports, 13