A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements

被引:51
|
作者
Benni, Paul B. [1 ]
MacLeod, David [2 ]
Ikeda, Keita [2 ,3 ]
Lin, Hung-Mo [4 ]
机构
[1] CAS Med Syst CASMED Inc, Branford, CT 06405 USA
[2] Duke Univ, Med Ctr, Dept Anesthesiol, Human Pharmacol & Physiol Lab, Durham, NC 27710 USA
[3] Univ Virginia, Dept Anesthesiol, Charlottesville, VA USA
[4] Icahn Sch Med Mt Sinai, Dept Populat Hlth Sci & Policy, New York, NY 10029 USA
基金
美国国家卫生研究院;
关键词
Tissue oximetry; Cerebral oximetry; Near Infrared Spectroscopy; NIRS; Tissue oxygen; Saturation; FDA; CONCORDANCE CORRELATION-COEFFICIENT; POSITRON-EMISSION-TOMOGRAPHY; CONGENITAL HEART-DISEASE; INTERNAL JUGULAR VEINS; TIDAL CARBON-DIOXIDE; RISK CARDIAC-SURGERY; BLOOD-VOLUME; HEALTHY-VOLUNTEERS; IN-VIVO; OXIDATIVE-METABOLISM;
D O I
10.1007/s10877-017-0015-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We describe the validation methodology for the NIRS based FORE-SIGHT ELITEA (R) (CAS Medical Systems, Inc., Branford, CT, USA) tissue oximeter for cerebral and somatic tissue oxygen saturation (StO(2)) measurements for adult subjects submitted to the United States Food and Drug Administration (FDA) to obtain clearance for clinical use. This validation methodology evolved from a history of NIRS validations in the literature and FDA recommended use of Deming regression and bootstrapping statistical validation methods. For cerebral validation, forehead cerebral StO(2) measurements were compared to a weighted 70:30 reference (REF CXB) of co-oximeter internal jugular venous and arterial blood saturation of healthy adult subjects during a controlled hypoxia sequence, with a sensor placed on the forehead. For somatic validation, somatic StO(2) measurements were compared to a weighted 70:30 reference (REF CXS) of co-oximetry central venous and arterial saturation values following a similar protocol, with sensors place on the flank, quadriceps muscle, and calf muscle. With informed consent, 25 subjects successfully completed the cerebral validation study. The bias and precision (1 SD) of cerebral StO(2) compared to REF CXB was -0.14 +/- 3.07%. With informed consent, 24 subjects successfully completed the somatic validation study. The bias and precision of somatic StO(2) compared to REF CXS was 0.04 +/- 4.22% from the average of flank, quadriceps, and calf StO(2) measurements to best represent the global whole body REF CXS. The NIRS validation methods presented potentially provide a reliable means to test NIRS monitors and qualify them for clinical use.
引用
收藏
页码:269 / 284
页数:16
相关论文
共 50 条
  • [21] Peripheral tissue oximetry: comparing three commercial near-infrared spectroscopy oximeters on the forearm
    Simon Hyttel-Sorensen
    Trine Witzner Hessel
    Gorm Greisen
    Journal of Clinical Monitoring and Computing, 2014, 28 : 149 - 155
  • [22] Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter
    Marimon, Gilma A.
    Dockery, W. Keith
    Sheridan, Michael J.
    Agarwal, Swati
    JOURNAL OF CRITICAL CARE, 2012, 27 (03) : 314.e13 - 314.e18
  • [23] Correlation of brain tissue oxygen tension with cerebral near-infrared spectroscopy and mixed venous oxygen saturation during extracorporeal membrane oxygenation
    Tyree, Kreangkai
    Tyree, Melissa
    DiGeronimo, Robert
    PERFUSION-UK, 2009, 24 (05): : 325 - 331
  • [24] Noninvasive tissue oxygen saturation determined by near-infrared spectroscopy following peripheral nerve block
    Tighe, P. J.
    Elliott, C. E.
    Lucas, S. D.
    Boezaart, A. P.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (10) : 1239 - 1246
  • [25] Regional tissue oxygen saturation measured by near-infrared spectroscopy to assess the depth of burn injuries
    Seki, Tadahiko
    Fujioka, Masayuki
    Fukushima, Hidetada
    Matsumori, Hiroaki
    Maegawa, Naoki
    Norimoto, Kazunobu
    Okuchi, Kazuo
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2014, 4 (01): : 40 - 44
  • [26] Near-infrared spectroscopy assessment of testicular tissue oxygen saturation in healthy controls and male infertility
    Kanayama, N.
    So, S.
    Murabayashi, N.
    Masuda, H.
    Tawara, F.
    HUMAN REPRODUCTION, 2017, 32 : 156 - 156
  • [27] Quantitative determination of the tissue oxygen saturation using frequency-domain near-infrared spectroscopy
    Zhao, Jun
    Ding, Haishu
    Teng, Yichao
    Guangzi Xuebao/Acta Photonica Sinica, 2005, 34 (03): : 386 - 389
  • [28] Near-Infrared Spectral Study on Blood Oxygen Saturation in Multilayer Tissue
    Gao Bo
    Wei Wei
    Gong Min
    Wang Li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (11) : 2922 - 2925
  • [29] Validation of phase-modulated near infrared spectroscopy with cerebral oxygen saturation measurements in children.
    Watzman, HM
    Kurth, CD
    Rome, J
    Nicolson, SC
    Steven, JM
    Montenegro, LM
    ANESTHESIOLOGY, 1998, 89 (3A) : U369 - U369
  • [30] Validation of phase-modulated near infrared spectroscopy cerebral oxygen saturation measurements in children.
    Watzman, HM
    Kurth, CD
    Rome, J
    Nicolson, SC
    Steven, JM
    Montenegro, LM
    JOURNAL OF INVESTIGATIVE MEDICINE, 1998, 46 (01) : 183A - 183A