Real-time myocardial contrast echocardiography for pharmacologic stress testing: Is quantitative estimation of myocardial blood flow reserve necessary?

被引:27
|
作者
Korosoglou, G
da Silva, KGC
Labadze, N
Dubart, AE
Hansen, A
Rosenberg, M
Zehelein, J
Kuecherer, H
机构
[1] Heidelberg Univ, Dept Cardiol, D-69115 Heidelberg, Germany
[2] Univ Lille, Clin Invest Ctr, Lille, France
关键词
D O I
10.1016/j.echo.2003.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Little is known about the diagnostic accuracy of quantitative real-time myocardial contrast echocardiography (MCE) as an adjunct to stress testing. This study was performed to evaluate the agreement between MCE and technetium 99m-sestamibi single photon emission computed tomography (SPECT) for detection of perfusion defects and to investigate whether quantitative assessment of myocardial perfusion can increase the diagnostic value of MCE. Methods. MCE was performed at rest and during peak adenosine stress in 50 unselected patients undergoing SPECT imaging. Concordance between the 2 methods was assessed using K statistics. MCE images were analyzed quantitatively, measuring peak intensity (A) and maximal rise of signal intensity (beta). Myocardial blood flow reserve was estimated by calculating the ratios of A(adenosine)/A(baseline) (A reserve), beta(adenosine)/beta(baseline) (beta reserve), and A x beta(adenosine)/A x beta(baseline) (A X beta reserve). Results: Visual analysis of MCE agreed well with SPECT (K = 0.67) with sensitivity of 64%, specificity of 97%, and overall accuracy of 87%. Quantitative analysis showed that peak signal intensity A significantly increased under adenosine stress in SPECT-normal segments (2.6 +/- 1.9 vs 3.0 +/- 1.6 dB, P < .0001), tendencially decreased in reversible (3.0 +/- 2.0 vs 2.4 +/- 1.2 dB, P = .07) and remained unchanged in fixed (0.9 +/- 0.9 vs 0.8 +/- 0.9 dB) defects. P increased markedly under adenosine in normal segments (0.4 +/- 0.4 vs 1.4 +/- 1.3, beta < .0001) but not in segments with reversible or fixed defects. Receiver operating characteristic showed that beta reserve and A x beta reserve, but not A reserve, are sensitive parameters for detecting perfusion defects with areas under the curve of 0.84, 0.85, and 0.61, respectively. Cut-off values of 1.9 and 2.3, respectively, for beta and A x beta reserve yielded sensitivity rates of 79% and 80%, specificity rates of 75% and 78%, and overall accuracy rates of 76% and 79%, respectively. Conclusion: Quantitative estimation of myocardial blood flow reserve by MCE parameters corresponds to the evaluation of myocardial perfusion by nuclear imaging and can increase the sensitivity but not the overall accuracy of contrast echocardiography.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Early impairment of myocardial blood flow reserve in men with essential hypertension: A quantitative myocardial contrast echocardiography study
    Di Bello, V
    Giorgi, D
    Pedrinelli, R
    Talini, E
    Palagi, C
    Delle Donne, MG
    Zucchelli, G
    Di Cori, A
    Paterni, M
    Dell'Omo, G
    Mariani, M
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) : 1037 - 1043
  • [22] Quantification of myocardial blood flow and assessment of its transmural distribution with real-time power modulation myocardial contrast echocardiography
    Van Camp, G
    Ay, T
    Pasquet, A
    London, V
    Bol, A
    Gisellu, G
    Hendrickx, G
    Rafter, P
    Melin, JA
    Vanoverschelde, JLJ
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (03) : 263 - 270
  • [23] Comparison of Coronary Blood Flow and Coronary Blood Flow Reserve in Hypercholesterolemia Before and After Atorvastatin Treatment Using Real-Time Myocardial Contrast Echocardiography
    Lario, Fabio C.
    Miname, Marcio H.
    Tsutsui, Jeane M.
    Kowatsch, Ingrid
    Sbano, Joao C.
    Santos, Raul D., Jr.
    Mathias, Wilson, Jr.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A252 - A252
  • [24] Numerical Methods and Workstation for the Quantitative Analysis of Real-Time Myocardial Contrast Echocardiography
    Sun, Feng-rong
    Zhang, Ming-qiang
    Jia, Xiao-bo
    Wang, Xiao-jing
    Yao, Gui-hua
    Zhang, Yun
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (05): : 1204 - 1210
  • [25] Quantitative assessment of cardiac allograft vasculopathy by real-time myocardial contrast echocardiography
    Uebleis, C.
    Hoyer, X.
    Ueberfuhr, P.
    Stempfle, H. U.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : S47 - S47
  • [26] Real-time contrast echocardiography predicts contractile reserve early after myocardial infarction
    Swinburn, JMA
    Lahiri, A
    Senior, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 396A - 396A
  • [27] Estimation of coronary artery stenosis by low-dose adenosine stress real-time myocardial contrast echocardiography: a quantitative study
    Zhou Xiao
    Zhi Guang
    Xu Yong
    Wang Jing
    Yan Guo-hui
    CHINESE MEDICAL JOURNAL, 2012, 125 (10) : 1795 - 1798
  • [29] Value of quantitative real-time myocardial contrast echocardiography in detection of viable myocardium after myocardial infarction
    Lee, SC
    Lee, KJ
    Kim, DK
    Lee, SH
    Hong, KP
    Park, JE
    Seo, JD
    CIRCULATION, 2003, 107 (19) : E145 - E145
  • [30] Myocardial contrast echocardiography provides a noninvasive estimation of fractional flow reserve
    Abbas, AE
    Moreno, CA
    Lester, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 310A - 310A