QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY

被引:2
|
作者
Lei Zhuang 1 *
机构
关键词
real-time three-dimensional echocardiography; contrast; perfusion defects; myocardial infarction;
D O I
暂无
中图分类号
R540.4 [诊断学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 50 条
  • [1] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    陈立新
    王新房
    Navin C anda
    Andrew P Miller
    谢明星
    庄磊
    杨娅
    王静
    黄润青
    杨颖
    费洪文
    王良玉
    [J]. 中华医学杂志(英文版), 2004, (03) : 18 - 22
  • [2] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    Chen, LX
    Wang, XF
    Nanda, NC
    Miller, AP
    Xie, MX
    Zhuang, L
    Yang, Y
    Wang, J
    Huang, RQ
    Yang, Y
    Fei, HW
    Wang, LY
    [J]. CHINESE MEDICAL JOURNAL, 2004, 117 (03) : 337 - 341
  • [3] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    陈立新
    王新房
    Navin C anda
    Andrew P Miller
    谢明星
    庄磊
    杨娅
    王静
    黄润青
    杨颖
    费洪文
    王良玉
    [J]. Chinese Medical Journal, 2004, (03)
  • [4] Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography
    Camarano, G
    Jones, M
    Freidlin, RZ
    Panza, JA
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) : 206 - 213
  • [5] Contrast enhanced real-time three-dimensional echocardiography for quantification of myocardial perfusion: a step forward
    Badano, Luigi P.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (04): : 465 - 466
  • [6] Real-time three-dimensional myocardial contrast echocardiography: is it clinically feasible?
    Bhan, A.
    Kapetanakis, S.
    Rana, B. S.
    Ho, E.
    Wilson, K.
    Pearson, P.
    Mushemi, S.
    Deguzman, J.
    Reiken, J.
    Harden, M. D.
    Walker, N.
    Rafter, P. G.
    Monaghan, M. J.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06): : 761 - 765
  • [7] Quantitative assessment of myocardial perfusion using real-time three-dimensional echocardiographic Imaging
    Toledo, E
    Lang, RM
    Collins, KA
    Williams, U
    Lammertin, G
    Weinert, L
    Mor-Avi, V
    [J]. Computers in Cardiology 2004, Vol 31, 2004, 31 : 225 - 228
  • [8] Imaging and quantification of myocardial perfusion using real-time three-dimensional echocardiography
    Toledo, E
    Lang, RM
    Collins, KA
    Lammertin, G
    Williams, U
    Weinert, L
    Bolotin, G
    Coon, PD
    Raman, J
    Jacobs, LD
    Mor-Avi, V
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) : 146 - 154
  • [9] Visualization of myocardial hemorrhage with real-time three-dimensional myocardial contrast echocardiography in patients with acute myocardial infarction
    Iwakura K.
    Okamura A.
    Koyama Y.
    Date M.
    Higuchi Y.
    Inoue K.
    Fujii K.
    [J]. Journal of Echocardiography, 2011, 9 (4) : 154 - 155
  • [10] Assessment of myocardial perfusion with real-time myocardial contrast echocardiography: Methodology and clinical applications
    Abdou Elhendy
    Thomas R. Porter
    [J]. Journal of Nuclear Cardiology, 2005, 12 : 582 - 590