Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens

被引:5
|
作者
Mieno, Hiroki [1 ,2 ]
Hieda, Osamu [1 ]
Ikeda, Toshihide [2 ]
Hayashi, Shino [2 ]
Hashida, Masatsugu [2 ]
Urabe, Kimiaki [2 ]
Sotozono, Chie [1 ]
机构
[1] Kyoto Prefectural Univ Med, Dept Ophthalmol, Kyoto, Japan
[2] Machida Hosp, Kochi, Japan
关键词
Barrett Universal II formula; IOLMaster (R) 700; Vivinex (TM) iSert (R) XY1 IOL; POWER CALCULATION;
D O I
10.4103/ijo.IJO_3455_20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the commonly used formulas for intraocular lens ( IOL) selection using IOLMaster (R) 700 (Carl Zeiss Meditec) and to evaluate the Barrett Universal II (BU-II) formula accuracy when using the Vivinex (TM) iSert (R) XY1 IOL (Hoya Corporation Medical Division). Methods: A retrospective chart review was performed that included patients who underwent uneventful cataract surgery with in-the-bag insertion of Vivinex (TM) iSert (R) XY1 IOL. Prediction errors at 3 months postoperative of IOLMaster (R) 700 with Haigis, Holladay 1, SRK/T, and BU-II formulas were compared. As a subgroup analysis, we focused on the axial length (AL) and IOL power. AL subgroup analysis was based on the following AL subgroups: short (<22.5 mm), medium (22.5-25.5 mm), and long (>25.5 mm). IOL power subgroup analysis was based on the following IOL power subgroups: low (<= 18.0 diopters [D]), medium (18.5-24.0 D), and high (>= 24.5 D). Results: This study included 590 eyes of 590 patients. Overall, the four IOL calculation formulas appeared to be similarly accurate. In the long AL subgroup, the BU-II formula had a significantly lower absolute error (AE) than the Holladay 1 formula. In the low-power subgroup, the BU-II formula had a significantly lower AE than the Holladay 1 and SRK/T formulas. On the other hand, in the high-power subgroup, the BU-.formula was significantly less accurate than the SRK/T formula and also appeared to be worse than the Holladay 1 formula (P = 0.052). Conclusion: The BU-II formula might be less accurate when using a Vivinex (TM) iSert (R) XY1 IOL of 24.5 D or greater.
引用
收藏
页码:2298 / 2302
页数:5
相关论文
共 7 条
  • [1] Comment on: Accuracy of the Barrett universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens
    Shrivastava, Ankur Kumar
    Nayak, Swatishree
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (02) : 692 - 692
  • [2] Response to comment on: Accuracy of the Barrett Universal II formula integrated into a commercially-available optical biometer when using a preloaded single-piece intraocular lens
    Mieno, Hiroki
    Hieda, Osamu
    Ikeda, Toshihide
    Hayashi, Shino
    Hashida, Masatsugu
    Urabe, Kimiaki
    Sotozono, Chie
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (02) : 693 - 693
  • [3] Accuracy of Intraocular Lens Power Calculation Using Anterior Chamber Depth from Two Devices with Barrett Universal II Formula
    Castro, Hannah Muniz
    Tai, Audrey X.
    Sampson, Samuel J.
    Wade, Matthew
    Farid, Marjan
    Garg, Sumit
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [4] Intraocular lens power calculation in virgin eyes: Accuracy of the Barrett Universal II formula and a Ray tracing software
    Fernandez-Roses, Joaquim
    Lamarca, Jose
    Pinero, David P.
    Barraquer, Rafael, I
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2954 - 2960
  • [5] To compare the refractive outcomes after cataract surgery using conventional keratometry (K) with Barrett Universal II formula and total keratometry (TK) with Barrett TK Universal II formula for intraocular lens power calculation
    Saini, Pragya
    Choudhry, Saurabh
    Rajput, Meetu
    Sen, Sagnik
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [6] Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas
    Moshirfar, Majid
    Sulit, Christian A.
    Brown, Alex H.
    Irwin, Chase
    Ronquillo, Yasmyne C.
    Hoopes, Phillip C.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2643 - 2652
  • [7] Evaluation of Barrett Universal II, SRK-T, and Haigis formulae for intraocular lens power calculation in myopes using optical biometry
    Aziz, Demiana W.
    Osman, Moataz H.
    Hassan, Nihal A.
    Bahgat, Nermeen M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2021, 114 (03) : 69 - 72