New Approach for Optimal Location and Parameters Setting of UPFC for Enhancing Power Systems Stability under Contingency Analysis

被引:15
|
作者
Zahid, Muhammad [1 ]
Chen, Jinfu [1 ]
Li, Yinhong [1 ]
Duan, Xianzhong [1 ]
Lei, Qi [1 ]
Bo, Wang [2 ]
Mohy-ud-Din, Ghulam [3 ,4 ]
Waqar, Asad [5 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[2] State Grid Hubei Elect Power Co Technol, Project 52153816000Y, Wuhan 430074, Peoples R China
[3] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW 2522, Australia
[4] COMSATS Inst Informat Technol, Dept Elect Engn, Wah Cantt 47040, Pakistan
[5] Bahria Univ, Dept Elect Engn, Islamabad 44000, Pakistan
来源
ENERGIES | 2017年 / 10卷 / 11期
关键词
optimal power flow; Artificial Algae Algorithm (AAA); Unified Power Flow Controller (UPFC); contingency; Performance Parameter (PP); ARTIFICIAL ALGAE ALGORITHM; OPTIMAL PLACEMENT; FACTS DEVICES; DYNAMIC STABILITY; FLOW; OPTIMIZATION; ENHANCEMENT; IMPROVE;
D O I
10.3390/en10111738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation of power system within specified limits of voltage and frequency are the major concerns in power system stability studies. As power system is always prone to disturbances, which consequently affect the voltage instability and optimal power flow, and therefore risks the power systems stability and security. In this paper, a novel technique based on the "Artificial Algae Algorithm" (AAA) is introduced, to identify the optimal location and the parameters setting of Unified Power Flow Controller (UPFC) under N-1 contingency criterion. In the first part, we have carried out a contingency operation and ranking process for the most parlous lines outage contingencies while taking the transmission lines overloading (NOLL) and voltage violation of buses (NVVB) as a performance parameter (PP = NOLL + NVVB). As UPFC possesses too much prohibitive cost and larger size, its optimal location and size must be identified before the actual deployment. In the second part, we have applied a novel AAA technique to identify the optimal location and parameters setting of UPFC under the discovered contingencies. The simulations have been executed on IEEE 14 bus and 30 bus networks. The results reveals that the location of UPFC is significantly optimized using AAA technique, which has improved the stability and security of the power system by curtailing the overloaded transmission lines and limiting the voltage violations of buses.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] A New Design Method for Optimal Parameters Setting of PSSs and SVC Damping Controllers to Alleviate Power System Stability Problem
    Farah, Anouar
    Belazi, Akram
    Alqunun, Khalid
    Almalaq, Abdulaziz
    Alshammari, Badr M.
    Ben Hamida, Mohamed Bechir
    Abbassi, Rabeh
    ENERGIES, 2021, 14 (21)
  • [42] Voltage stability analysis in unbalanced power systems by optimal power flow
    Carpinelli, G.
    Lauria, D.
    Varilone, P.
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (03) : 261 - 268
  • [43] An intermittent contingency approach with optimal placement of static VAR compensator in a renewable -integrated power systems
    Rambabu M.
    Kumar G.V.N.
    Sivanagaraju S.
    International Journal of Ambient Energy, 2021, 42 (13) : 1551 - 1561
  • [44] Detection and Location of Open Conductor Faults for Power Distribution Networks Using a Contingency Analysis Approach
    Sim, Gi-Do
    Im, Hyo-Seop
    Choi, Joon-Ho
    Ahn, Seon-Ju
    Yun, Sang-Yun
    IEEE ACCESS, 2024, 12 : 114304 - 114318
  • [45] Efficient and optimal approach for location and parameter setting of multiple unified power flow controllers for a deregulated power sector
    Tiwari, P. K.
    Sood, Y. R.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (10) : 958 - 967
  • [46] Optimal Wind Power Location on Transmission Systems - A Probabilistic Load Flow Approach
    Burke, D. J.
    O'Malley, M. J.
    2008 10TH INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, 2008, : 117 - 124
  • [47] A Novel Approach to Determine the Optimal Location of SFCL in Electric Power Grid to Improve Power System Stability
    Didier, G.
    Leveque, Jean
    Rezzoug, Abderrezak
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) : 978 - 984
  • [48] A novel collapse prediction index for voltage stability analysis and contingency ranking in power systems
    Mokred, Salah
    Wang, Yifei
    Chen, Tiancong
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [49] A novel collapse prediction index for voltage stability analysis and contingency ranking in power systems
    Salah Mokred
    Yifei Wang
    Tiancong Chen
    Protection and Control of Modern Power Systems, 2023, 8
  • [50] Optimal Location of STATCOM and SVC Based on Contingency Voltage Stability by Using Continuation Power Flow:Case Studies of Khouzestan Power Networks in Iran
    Larki, Farbod
    Kelk, Homayoun Meshgin
    Pishvaei, M.
    Johar, Ali
    Joorabian, Mahmood
    SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING, VOL 1, PROCEEDINGS, 2009, : 179 - +