New Approach for Optimal Location and Parameters Setting of UPFC for Enhancing Power Systems Stability under Contingency Analysis

被引:15
|
作者
Zahid, Muhammad [1 ]
Chen, Jinfu [1 ]
Li, Yinhong [1 ]
Duan, Xianzhong [1 ]
Lei, Qi [1 ]
Bo, Wang [2 ]
Mohy-ud-Din, Ghulam [3 ,4 ]
Waqar, Asad [5 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[2] State Grid Hubei Elect Power Co Technol, Project 52153816000Y, Wuhan 430074, Peoples R China
[3] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW 2522, Australia
[4] COMSATS Inst Informat Technol, Dept Elect Engn, Wah Cantt 47040, Pakistan
[5] Bahria Univ, Dept Elect Engn, Islamabad 44000, Pakistan
来源
ENERGIES | 2017年 / 10卷 / 11期
关键词
optimal power flow; Artificial Algae Algorithm (AAA); Unified Power Flow Controller (UPFC); contingency; Performance Parameter (PP); ARTIFICIAL ALGAE ALGORITHM; OPTIMAL PLACEMENT; FACTS DEVICES; DYNAMIC STABILITY; FLOW; OPTIMIZATION; ENHANCEMENT; IMPROVE;
D O I
10.3390/en10111738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation of power system within specified limits of voltage and frequency are the major concerns in power system stability studies. As power system is always prone to disturbances, which consequently affect the voltage instability and optimal power flow, and therefore risks the power systems stability and security. In this paper, a novel technique based on the "Artificial Algae Algorithm" (AAA) is introduced, to identify the optimal location and the parameters setting of Unified Power Flow Controller (UPFC) under N-1 contingency criterion. In the first part, we have carried out a contingency operation and ranking process for the most parlous lines outage contingencies while taking the transmission lines overloading (NOLL) and voltage violation of buses (NVVB) as a performance parameter (PP = NOLL + NVVB). As UPFC possesses too much prohibitive cost and larger size, its optimal location and size must be identified before the actual deployment. In the second part, we have applied a novel AAA technique to identify the optimal location and parameters setting of UPFC under the discovered contingencies. The simulations have been executed on IEEE 14 bus and 30 bus networks. The results reveals that the location of UPFC is significantly optimized using AAA technique, which has improved the stability and security of the power system by curtailing the overloaded transmission lines and limiting the voltage violations of buses.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] A new approach for congestion management via optimal location of FACTS devices in deregulated power systems
    Gitizadeh, M.
    Kalantar, M.
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1592 - 1597
  • [32] ENHANCEMENT OF VOLTAGE STABILITY AND REDUCTION OF POWER LOSS USING GENETIC ALGORITHM THROUGH OPTIMAL LOCATION OF SVC, TCSC AND UPFC
    Kalaivani, R.
    Dheebika, S. K.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2016, 11 (10): : 1470 - 1485
  • [33] OPTIMAL LOCATION OF SVC, TCSC AND UPFC DEVICES FOR VOLTAGE STABILITY IMPROVEMENT AND REDUCTION OF POWER LOSS USING GENETIC ALGORITHM
    Dheebika, S. K.
    Kalaivani, R.
    2014 INTERNATIONAL CONFERENCE ON GREEN COMPUTING COMMUNICATION AND ELECTRICAL ENGINEERING (ICGCCEE), 2014,
  • [34] A new approach for optimal location of TCSC in a power system to enhance voltage stability: steady state studies
    Gitizadeh, M.
    Kalantar, M.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 570 - 575
  • [35] ANALYSIS OF OPTIMAL VOLTAGE STABILITY IN POWER SYSTEMS WITH WIND POWER
    Sugirtha, M. G.
    Latha, P.
    Karuppiah, N.
    Shanmugapriyan, J.
    2017 INTERNATIONAL CONFERENCE ON COMPUTING METHODOLOGIES AND COMMUNICATION (ICCMC), 2017, : 926 - 930
  • [36] A new optimal design of ACD-based UPFC supplementary controller for interconnected power systems
    Makvandi, Hojatollah
    Joorabian, Mahmood
    Barati, Hassan
    MEASUREMENT, 2021, 182
  • [37] Optimal location and parameters setting of unified power flow controller based on evolutionary optimization techniques
    Shaheen, H. I.
    Rashed, G. I.
    Cheng, S. J.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1478 - 1485
  • [38] A New Approach to Real Time Line Outage Contingency Analysis for Voltage Secure Operation of Power Systems
    Suthar, Bhavik
    Balasubramanian, R.
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 30 - +
  • [39] A new approach to real time line outage contingency analysis for voltage secure operation of power systems
    Indian Institute of Technology IIT, Delhi 110016, India
    不详
    Jt. Int. Conf. Power Syst. Technol. POWERCON IEEE Power India Conf., POWERCON, 2008,
  • [40] Contingency ranking for voltage stability analysis of large-scale power systems
    Poshtan, M
    Rastgoufard, P
    Singh, B
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 1506 - 1513