The Effect of the Number of Fields on Radiotherapy Plans of Breast Cancer Patients in Three-Dimensionally Conformal Radiotherapy Plans: Dosimetric Studies

被引:1
|
作者
Bazeed, Zezy Mansour [1 ]
Attalla, Ehab Maarouf [2 ]
Awad, Ibrahim Ali Mohamed [1 ]
Hamid, Maysa Ismail Abdel [3 ]
Sarhan, Afaf [3 ]
机构
[1] Mansoura Univ, Fac Med, Dept Clin Oncol & Nucl Med, Mansoura, Egypt
[2] Cairo Univ, Natl Canc Inst, Dept Phys, Div Med Phys, Giza, Egypt
[3] Mansoura Univ, Fac Sci, Phys Dept, Polymer Res Grp, Mansoura, Egypt
关键词
Breast neoplasms; 3D; Conformal; Radiotherapy; DVH; RADIATION-THERAPY; WOMEN; MASTECTOMY; QUANTEC; RISK;
D O I
10.30476/mejc.2021.85935.1316
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The objective of this study was to compare the dosimetric outcome of plans with more fields to those with fewer ones for breast cancer patients. Method: 23 breast cancer patients were examined in this experimental study. Two groups of these patients were planned by treatment planning system. The number of beams was changed for each group, and the dosimetric parameters were calculated. The dose volume histogram (DVH) and the statistical analyses were performed for the two plans of all patients. Results: The DVH for the planning target volume (PTV) of the two techniques was estimated. Optimized plans were carried out to ensure that 95 % of the target volume takes 95 % of the dose. Based on the statistical analysis, the best coverage of dose had no relationship with the number of beams because the P-value of V-105 %, V-95%,V-110%, D-mean, D-max, conformity index, homogeneity index, and D5% were 0.9537, 0.9152, 0.3446, 0.8156, 0.9516, 0.7888, 0.2127, and 0.7282, respectively. The Mean +/- standard error of mean for all PTV parameters was nearly the same. Also, the organ at risk had no significant difference after changing the number of beams, which means that the complication to normal tissue was nearly the same for both plans. Conclusion: The number of beams has no effect on PTV and normal tissue. Therefore, it is important for medical physicists to conduct the optimized plan without exceeding the number of beams to reduce the scattered radiation.
引用
收藏
页码:516 / 526
页数:11
相关论文
共 50 条
  • [41] Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study
    Liu, Haiyun
    Chen, Xinde
    He, Zhijian
    Li, Jun
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2016, 54 : 1 - 5
  • [42] Dosimetric characteristics of tomotherapy and three- dimensional conformal radiotherapy for head and neck cancer
    Monadi, N.
    Shahbazi-Gahrouei, D.
    Monadi, S.
    Mahani, L.
    Shams, A.
    Akhavan, A.
    Mohammadi, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 427 - 434
  • [43] Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-corrected Conformal Treatment Plans for Lung Cancer Stereotactic Body Radiotherapy
    Li, J.
    Galvin, J.
    Harrison, A.
    Timmerman, R.
    Yu, Y.
    Xiao, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S854 - S854
  • [44] Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study
    Chan, Philip
    Yeo, Inhwan
    Perkins, Gregory
    Fyles, Anthony
    Milosevic, Michael
    RADIATION ONCOLOGY, 2006, 1 (1)
  • [45] Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study
    Philip Chan
    Inhwan Yeo
    Gregory Perkins
    Anthony Fyles
    Michael Milosevic
    Radiation Oncology, 1
  • [46] Dosimetric comparison of helical tomotherapy plans in breast cancer patients with silicone implants
    Elmali, Aysenur
    Bozca, Recep
    Dolek, Yemliha
    Guler, Ozan Cem
    Onal, Cem
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S466 - S468
  • [47] Simultaneous integrated boost in breast conserving treatment of breast cancer: A dosimetric comparison of helical tomotherapy and three-dimensional conformal radiotherapy
    Hijal, Tarek
    Fournier-Bidoz, Nathalie
    Castro-Pena, Pablo
    Kirova, Youlia M.
    Zefkili, Sophia
    Bollet, Marc A.
    Dendale, Remi
    Campana, Francois
    Fourquet, Alain
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (03) : 300 - 306
  • [48] The Risk of Secondary Malignancies as An Evaluation Factor in the Comparison of Prostate Cancer Intensity Modulated Radiotherapy (IMRT) and Conformal Radiotherapy (CRT) Treatment Plans
    Komisopoulos, G.
    Buckey, C.
    Stathakis, S.
    Sakellaropoulos, G.
    Kardamakis, D.
    Nikoforidis, G.
    Papanikolaou, N.
    Mavroidis, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3507 - 3507
  • [49] A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    Karger, CP
    Jäkel, O
    Hartmann, GH
    Heeg, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2125 - 2132
  • [50] The comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer
    Izmirli, M.
    Yilmazer, G.
    Cakir, T.
    Palabiyik, Z. A.
    Nart, M.