The Effect of the Number of Fields on Radiotherapy Plans of Breast Cancer Patients in Three-Dimensionally Conformal Radiotherapy Plans: Dosimetric Studies

被引:1
|
作者
Bazeed, Zezy Mansour [1 ]
Attalla, Ehab Maarouf [2 ]
Awad, Ibrahim Ali Mohamed [1 ]
Hamid, Maysa Ismail Abdel [3 ]
Sarhan, Afaf [3 ]
机构
[1] Mansoura Univ, Fac Med, Dept Clin Oncol & Nucl Med, Mansoura, Egypt
[2] Cairo Univ, Natl Canc Inst, Dept Phys, Div Med Phys, Giza, Egypt
[3] Mansoura Univ, Fac Sci, Phys Dept, Polymer Res Grp, Mansoura, Egypt
关键词
Breast neoplasms; 3D; Conformal; Radiotherapy; DVH; RADIATION-THERAPY; WOMEN; MASTECTOMY; QUANTEC; RISK;
D O I
10.30476/mejc.2021.85935.1316
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The objective of this study was to compare the dosimetric outcome of plans with more fields to those with fewer ones for breast cancer patients. Method: 23 breast cancer patients were examined in this experimental study. Two groups of these patients were planned by treatment planning system. The number of beams was changed for each group, and the dosimetric parameters were calculated. The dose volume histogram (DVH) and the statistical analyses were performed for the two plans of all patients. Results: The DVH for the planning target volume (PTV) of the two techniques was estimated. Optimized plans were carried out to ensure that 95 % of the target volume takes 95 % of the dose. Based on the statistical analysis, the best coverage of dose had no relationship with the number of beams because the P-value of V-105 %, V-95%,V-110%, D-mean, D-max, conformity index, homogeneity index, and D5% were 0.9537, 0.9152, 0.3446, 0.8156, 0.9516, 0.7888, 0.2127, and 0.7282, respectively. The Mean +/- standard error of mean for all PTV parameters was nearly the same. Also, the organ at risk had no significant difference after changing the number of beams, which means that the complication to normal tissue was nearly the same for both plans. Conclusion: The number of beams has no effect on PTV and normal tissue. Therefore, it is important for medical physicists to conduct the optimized plan without exceeding the number of beams to reduce the scattered radiation.
引用
收藏
页码:516 / 526
页数:11
相关论文
共 50 条
  • [21] Dosimetric comparison of organs at risk in 5 different radiotherapy plans in patients with preoperatively irradiated rectal cancer
    Bakkal, Bekir Hakan
    Elmas, Ozlem
    MEDICINE, 2021, 100 (01) : E24266
  • [22] DOSIMETRIC COMPARISON OF FIELD IN FIELD INTENSITY MODULATED RADIOTHERAPY TECHNIQUE WITH CONFORMAL RADIOTHERAPY TECHNIQUES IN BREAST CANCER
    Ercan, T.
    Igdem, S.
    Alco, G.
    Zengin, F.
    Ozgules, R.
    Atilla, S.
    Dincer, M.
    Okkan, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S201 - S202
  • [23] A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana
    Kyei, Kofi Adesi
    Daniels, Joseph
    Adom, Ameyaw Kwame
    Odonkor, Philip
    Nyantakyi, Andrew Yaw
    Adjabu, Dorothy Ekua
    ECANCERMEDICALSCIENCE, 2024, 18
  • [24] A Dosimetric Comparative Analysis of Tomo Direct and Three-Dimensional Conformal Radiotherapy in Early Breast Cancer
    Chung, Mi Joo
    Kim, Sung Hwan
    Lee, Jong Hoon
    Suh, Young Jin
    JOURNAL OF BREAST CANCER, 2015, 18 (01) : 57 - 62
  • [25] Dosimetric comparison of library of plans and online MRI-guided radiotherapy of cervical cancer
    Visser, J.
    De Boer, P.
    Crama, K. F.
    Van Kesteren, Z.
    Rasch, C. R. N.
    Stalpers, L. J. A.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S535 - S536
  • [26] Dosimetric Evaluation of Three-dimensional Conformal Radiotherapy, RapidArc, and Hybrid RapidArc Radiotherapy Techniques for Left-sided Breast Cancer
    Mishra, Atul
    Yadav, Neha
    Sharma, Madhu
    Mittal, Kailash Kumar
    Mishra, Surendra Prasad
    Verma, Teerth Raj
    Tiwari, Shilpa
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 93 - 99
  • [27] Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer
    Yavas, G.
    Yavas, C.
    Acar, H.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2012, 10 (3-4): : 131 - 138
  • [28] Integration of radiation doses and myocardial function in radiotherapy plans for breast cancer
    Yang, S.
    Lin, K.
    Yu, C.
    Hsu, C.
    Wang, S.
    Shueng, P.
    Wu, T.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S79 - S79
  • [29] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy (3DCRT) and Volumetric Modulated Arc Therapy (VMAT) Plans for Hypofractionated Whole Breast and Regional Nodes Irradiation in Breast Cancer Patients Following Breast Conservative Surgery
    Khosla, D.
    Kapoor, R.
    Rana, S.
    Tomar, P.
    Periasamy, K.
    Madan, R.
    Goyal, S.
    Kumar, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E321 - E321
  • [30] Determination and comparison of dosimetric parameters of three-dimensional conformal radiotherapy, field in field, and intensity-modulated radiotherapy techniques in radiotherapy of breast conserving patients
    Takabi, Fatemeh Shirani
    Broomand, Mohammad Ali
    Nickfarjam, Abolfazl
    Asadi, Amin
    Namiranian, Nasim
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 624 - 632