SUGGESTED DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC X-RAY EXAMINATIONS IN INDIA

被引:6
|
作者
Sonawane, A. U. [1 ]
Kumar, J. V. K. Sunil [1 ]
Singh, Meghraj [1 ]
Pradhan, A. S. [2 ]
机构
[1] Atom Energy Regulatory Board, Radiol Safety Div, Bombay 400094, Maharashtra, India
[2] Ex Bhabha Atom Res Ctr, Bombay, Maharashtra, India
关键词
RADIATION;
D O I
10.1093/rpd/ncq458
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code for Medical Diagnostic X-ray Equipment and Installations in India. Measurements were carried out for entrance surface air kerma (free in air) in conventional paediatric X-ray diagnostic examinations among four age groups: <1, 1-4, 5-9 and 10-15 y. A total of 2240 air kerma measurements at different fixed focus to skin distances were studied for 7 paediatric diagnostic examinations with 11 different projections on 62 X-ray machines installed in 22 selected hospitals in the country. The third quartile values of air kerma per paediatric examination for the age group of 5-9 y were considered as values of paediatric DRLs. The suggested values of DRLs are 0.2 mGy for chest AP/PA, 0.3 mGy for chest LAT, 0.7 mGy for lumber spine AP, 1.3 mGy for lumber spine LAT, 0.3 mGy for thoracic spine AP, 0.6 mGy for thoracic spine LAT, 0.5 mGy for abdomen AP, 0.7 mGy for pelvis AP, 0.6 mGy for skull PA, 0.5 mGy for skull LAT and 0.8 mGy for hip joints AP.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 50 条
  • [21] EMERGENCY X-RAY EXAMINATIONS IN PAEDIATRIC PRACTICE
    WALKER, N
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1962, 35 (416): : 577 - 577
  • [22] Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia
    Hiswara, E.
    Prasetio, H.
    Kartikasari, D.
    Nuraeni, N.
    Sandy, K. Y. P.
    [J]. ATOM INDONESIA, 2016, 42 (03) : 99 - 104
  • [23] Diagnostic Reference Levels for Common X-ray Procedures in Peru
    Portocarrero Bonifaz, Andres
    Camarena Rodriguez, Caterina S.
    Palma Esparza, Ricardo
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [24] Paediatric x-ray examinations in Rio de Janeiro
    Azevedo, A. C. P.
    Osibote, O. A.
    Boechat, M. C. B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15): : 3723 - 3732
  • [25] DIAGNOSTIC X-RAY EXAMINATIONS - NEED TO BE CONCERNED
    BONELLI, J
    [J]. MATERIALS EVALUATION, 1977, 35 (09) : 51 - 53
  • [26] Local diagnostic reference levels for routine chest X-ray examinations at a public sector hospital in central South Africa
    Junda, Maurice
    Muller, Henra
    Friedrich-Nel, Hesta
    [J]. HEALTH SA GESONDHEID, 2021, 26
  • [27] THE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK
    Martin, Colin J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 211 - 216
  • [28] Diagnostic Reference Levels for Diagnostic and Interventional X-Ray Procedures in Germany: Update and Handling
    Schegerer, Alexander
    Loose, Reinhard
    Heuser, Lothar J.
    Brix, Gunnar
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (08): : 739 - 751
  • [29] TREATMENT OF RENAL OSTEOPATHY BY ROCALTROL WITH SPECIAL REFERENCE TO PARATHORMONE LEVELS AND X-RAY EXAMINATIONS
    SCHMITT, RL
    OLAH, AJ
    JAHN, HA
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 1981, 10 (06) : 249 - 253
  • [30] Diagnostic reference levels for common paediatric fluoroscopic examinations performed at a dedicated paediatric Australian hospital
    Bibbo, Giovanni
    Balman, Debbie
    Linke, Rebecca
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 469 - 474