ICP-MS determination of lead isotope ratios in whole blood, pottery, and leaded gasoline: Lead sources in Mexico City

被引:0
|
作者
Chaudhary-Webb, M [1 ]
Paschal, DC [1 ]
Elliott, WC [1 ]
Hopkins, HP [1 ]
Ghazi, AM [1 ]
Ting, BC [1 ]
Romieu, I [1 ]
机构
[1] Ctr Dis Control & Prevent, US Publ Hlth Serv, Atlanta, GA 30341 USA
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Lead isotope ratios were measured with ICP-MS, using electrothermal vaporization for pottery, whole blood and leaded gasoline from residents of a small town in Mexico. Comparison was made of the isotope ratios Pb208/Pb204; Pb207/Pb204 and Pb208/Pb204. in ceramic cookware (pottery) and leaded gasoline and related whole blood specimens. It is apparent from the similarity of the two ratios that the predominant source of lead in this population is the ceramicware used for cooking.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 50 条
  • [21] Lead isotope ratios determined by ICP-MS: Investigation of anthropogenic lead in seawater and sediment from the Gulf of Carpentaria, Australia
    Munksgaard, NC
    Batterham, GJ
    Parry, DL
    [J]. MARINE POLLUTION BULLETIN, 1998, 36 (07) : 527 - 534
  • [22] Determination of Lead Isotope Ratios in Bullet Samples for Forensic Purpose by Single Collector High-resolution ICP-MS
    Shimamura, Yoshinori
    Nakai, Izumi
    [J]. BUNSEKI KAGAKU, 2013, 62 (09) : 765 - 774
  • [23] SOME APPLICATIONS OF ISOTOPE ANALYSIS OF LEAD IN FOOD BY ICP-MS
    CREWS, HM
    MASSEY, RC
    MCWEENY, DJ
    DEAN, JR
    EBDON, L
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 464 - 466
  • [24] Some applications of isotope analysis of lead in food by ICP-MS
    Crews, H.M.
    Massey, R.C.
    McWeeny, D.J.
    Dean, J.R.
    Ebdon, L.
    [J]. Journal of Research of the National Bureau of Standards (United States), 1988, 93 (03): : 464 - 466
  • [25] ICP-MS QUANTITATION OF LEAD IN BLOOD COLLECTED ON PAPER
    WONG, YW
    ASHWOOD, ER
    GORDON, W
    ASH, KO
    [J]. CLINICAL CHEMISTRY, 1995, 41 (06) : S145 - S145
  • [26] Determination of lead and lead isotope ratios in gasoline by inductively coupled plasma mass spectrometry
    Lord III, Charles J.
    [J]. Journal of analytical atomic spectrometry, 1994, 9 (05): : 599 - 603
  • [27] Determination of lead concentrations and isotope ratios in recent snow samples from high alpine sites with a double focusing ICP-MS
    Doring, T
    Schwikowski, M
    Gaggeler, HW
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5): : 382 - 384
  • [28] Determination of lead concentrations and isotope ratios in recent snow samples from high alpine sites with a double focusing ICP-MS
    T. Döring
    M. Schwikowski
    H. W. Gäggeler
    [J]. Fresenius' Journal of Analytical Chemistry, 1997, 359 : 382 - 384
  • [29] A lead isotope distribution study in swine tissue using ICP-MS
    May, TW
    Wiedmeyer, RH
    Brown, LD
    Casteel, SW
    [J]. ATOMIC SPECTROSCOPY, 1999, 20 (06) : 199 - 211
  • [30] Analysis of cadmium and lead in sediment by isotope-dilution ICP-MS
    Inagaki, K
    Takatsu, A
    Nakama, A
    Uchiumi, A
    Okamoto, K
    [J]. BUNSEKI KAGAKU, 2001, 50 (12) : 829 - 835