Determination of lead concentrations and isotope ratios in recent snow samples from high alpine sites with a double focusing ICP-MS

被引:34
|
作者
Doring, T
Schwikowski, M
Gaggeler, HW
机构
[1] PAUL SCHERRER INST,CH-5232 VILLIGEN,SWITZERLAND
[2] UNIV BERN,DEPT CHEM & BIOCHEM,CH-3012 BERN,SWITZERLAND
来源
关键词
D O I
10.1007/s002160050592
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A double focusing ICP-MS, equipped with a Micro Concentric Nebulizer, has been used to determine concentrations and isotopic ratios of lead in recent snow samples (1993-1996) from high alpine sites in Switzerland. Concentrations varied between 0.02 +/- 0.002 and 5.5 +/- 0.15 ng/g and are slightly lower than concentrations reported by Atteia [1], by Batifol et al. [2], and by Wagenbach et al, [3] for precipitation samples from similar remote sites in Europe. Since concentrations of lead in the fresh snow samples were mainly in the lower pg/g range, the method to determine the isotopic ratios Pb-207/Pb-206 and Pb-208/Pb-206 had to be optimized. They could finally be determined with an average standard error of 0.14% within 12 min and a total sample consumption of 0.8 mt. The average ratios Pb-207/Pb-206 and Pb-208/Pb-206 were 0.875 and 2.117, respectively. These values are comparable to isotopic compositions of lead in aerosols collected in Western Europe [4] and are less radiogenic than predicted by Grousset et al. [5]. Our data indicate that, although lead emissions from traffic have decreased largely during the last 10 years, the contribution from this source in modem snow is still detectable and seems to be equal to the lead input from other anthropogenic sources (e.g. waste incineration, industry).
引用
收藏
页码:382 / 384
页数:3
相关论文
共 50 条
  • [1] Determination of lead concentrations and isotope ratios in recent snow samples from high alpine sites with a double focusing ICP-MS
    T. Döring
    M. Schwikowski
    H. W. Gäggeler
    [J]. Fresenius' Journal of Analytical Chemistry, 1997, 359 : 382 - 384
  • [2] Determination of plutonium concentrations and isotope ratios in environmental samples with a double-focusing sector field ICP-MS
    Rodushkin, I
    Lindahl, P
    Holm, E
    Roos, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (2-3): : 472 - 479
  • [3] ICP-MS determination of lead isotope ratios in legal and counterfeit cigarette tobacco samples
    Judd, Christopher D.
    Swami, Kamal
    [J]. ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2010, 46 (04) : 484 - 494
  • [4] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    H. Kawamura
    H. Tagomori
    N. Matsuoka
    Y. Takashima
    S. Tawaki
    N. Momoshima
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 717 - 720
  • [5] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    Kawamura, H
    Tagomori, H
    Matsuoka, N
    Takashima, Y
    Tawaki, S
    Momoshima, N
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (03) : 717 - 720
  • [6] The determination of cadmium, lead and vanadium by high resolution ICP-MS in Antarctic snow samples
    Lanza, F
    Trincherini, PR
    [J]. ANNALI DI CHIMICA, 2000, 90 (1-2) : 61 - 71
  • [7] Determination of Lead Isotope Ratios in Bullet Samples for Forensic Purpose by Single Collector High-resolution ICP-MS
    Shimamura, Yoshinori
    Nakai, Izumi
    [J]. BUNSEKI KAGAKU, 2013, 62 (09) : 765 - 774
  • [8] Lead isotope measurements on aerosol samples with ICP-MS
    Widmer, CR
    Krähenbühl, U
    Kramers, J
    Tobler, L
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02): : 171 - 173
  • [9] Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics
    Mason, PRD
    Kaspers, K
    van Bergen, MJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (07) : 1067 - 1074
  • [10] Lead isotope measurements on aerosol samples with ICP-MS
    C. R. Widmer
    U. Krähenbühl
    J. Kramers
    L. Tobler
    [J]. Fresenius' Journal of Analytical Chemistry, 2000, 366 : 171 - 173