Positive end-expiratory pressure following coronary artery bypass grafting

被引:0
|
作者
Dongelmans, D. A. [1 ]
Hemmes, S. N. [1 ,2 ]
Kudoga, A. C. [1 ]
Veelo, D. P. [1 ]
Binnekade, J. M. [1 ]
Schultz, M. J. [1 ,2 ,3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Intens Care Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, LEICA, NL-1105 AZ Amsterdam, Netherlands
[3] HERMES Crit Care Grp, Amsterdam, Netherlands
关键词
Respiration; artificial; Ventilator weaning; Positive-pressure respiration; Patient compliance; Thoracic surgery; RESPIRATORY-DISTRESS-SYNDROME; ACUTE LUNG INJURY; CARDIOPULMONARY BYPASS; CARDIAC-SURGERY; TIDAL VOLUME; VENTILATION; PULMONARY; RECRUITMENT; EXTUBATION; SUPPORT;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiac surgery-related pulmonary complications include alterations in lung mechanics and anomalies in gas exchange. Higher levels of positive end-expiratory pressure (PEEP) have been suggested to benefit cardiac surgical patients. We compared respiratory compliance, arterial oxygenation and time rill tracheal extubation in 2 cohorts of patients weaned from mechanical ventilation with different levels of PEEP after elective and uncomplicated coronary artery bypass grafting (CABG). We hypothesized that higher PEEP levels improve pulmonary compliance and gas exchange in the first hours of weaning from mechanical ventilation, but not to shorten time till tracheal extubation. Methods. Secondary retrospective analysis of 2 randomized controlled trials: in the first trial patients were weaned with PEEP levels of 10 cmH(2)O for the first 4 hours followed by PEEP levels of 5 cmH(2)O until tracheal extubation (high PEEP, HP); and the second trial patients were weaned with PEEP levels of 5 cmH(2)O during the entire weaning phase (low PEEP LP). The primary endpoint was pulmonary compliance. Secondary endpoints included arterial oxygenation, duration of mechanical ventilation and postoperative pulmonary complications. Results. The analysis included 121 patients; 60 HP patients and 61 LP patients. Baseline characteristics were similar. Compared to LP patients, HP patients had a better pulmonary compliance, 47.2 +/- 14.1 versus 42.7 +/- 10.2 ml/cmH(2)O (P<0.05), and higher levels PaO2, 18.5 +/- 6.6 (138.75 +/- 49.5) versus 16.7 +/- 5.4 (125.25 +/- 40.5) kPa (mmHg) (P<0.05). Patients in the HP group were less frequent in need of supplementary oxygen after ICU discharge. These differences remained present during the entire weaning phase, even after reduction of PEEP. However, HP patients had a longer time rill tracheal extubation, 16.9 +/- 6.1 versus 10.5 +/- 5.0 hours (P<0.001). HP patients had longer durations of postoperative infusion of propofol, 4.9 (2.6-7.4) versus 3.5 (1.8-5.8) hours (P<0.05). There were no differences in use of inotropes. Cummulative fluid balances were sligthly higher in HP patients. Conclusion. Use of higher PEEP levels after elective uncomplicated CABG improves pulmonary compliance and oxygenation but seems to be associated with a delay in tracheal extubation. (Minerva Anestesiol 2012;78:790-800)
引用
收藏
页码:790 / 800
页数:11
相关论文
共 50 条
  • [21] POSITIVE END-EXPIRATORY PRESSURE - A REVIEW
    TYLER, DC
    CRITICAL CARE MEDICINE, 1983, 11 (04) : 300 - 308
  • [22] POSITIVE END-EXPIRATORY PRESSURE (PEEP)
    HEINRICHS, W
    ANAESTHESIST, 1992, 41 (10): : 653 - 669
  • [23] PEEP (positive end-expiratory pressure)
    Max, M
    ANAESTHESIST, 2001, 50 (03): : 198 - 199
  • [24] HEMODYNAMIC-RESPONSE TO POSITIVE END-EXPIRATORY PRESSURE FOLLOWING RIGHT ATRIUM PULMONARY-ARTERY BYPASS (FONTAN PROCEDURE)
    WILLIAMS, DB
    KIERNAN, PD
    METKE, MP
    MARSH, HM
    DANIELSON, GK
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1984, 87 (06): : 856 - 861
  • [25] Should we titrate positive end-expiratory pressure based on an end-expiratory transpulmonary pressure?
    Marini, John J.
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (19)
  • [26] THE EFFECT OF POSITIVE END-EXPIRATORY PRESSURE ON THE CORONARY BLOOD-FLOW
    BENHAIM, SA
    AMAR, R
    SHOFTY, R
    MERIN, G
    DINNAR, U
    CARDIOLOGY, 1989, 76 (03) : 193 - 200
  • [27] Effects of Two Different Levels of Positive End-Expiratory Pressure on the Duration of Intubation in Patients Undergoing Coronary Artery Bypass Graft Surgery
    Moradi, Behzad
    Yarahmadi, Sajad
    Ansari, Reza
    Teymouri, Hassan
    Khademi, Mojgan
    Abdi, Masoumeh
    IRANIAN HEART JOURNAL, 2020, 21 (03): : 55 - 63
  • [28] Effects of Positive End-Expiratory Pressure on Artery Coronary Flow in Patients with Acute Respiratory Distress Syndrome
    Zerbib, Yoann
    Schoux, Rosalie
    Richecoeur, Jack
    Bradier, Thomas
    Brault, Clement
    Kontar, Loay
    Lambour, Alexis
    Maizel, Julien
    Slama, Michel
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (05) : 598 - 601
  • [29] TRANSESOPHAGEAL TWO-DIMENSIONAL ECHOCARDIOGRAPHIC EVALUATION OF BIVENTRICULAR DIMENSION AND FUNCTION DURING POSITIVE END-EXPIRATORY PRESSURE VENTILATION AFTER CORONARY-ARTERY BYPASS-GRAFTING
    KOOLEN, JJ
    VISSER, CA
    WEVER, E
    VANWEZEL, H
    MEYNE, NG
    DUNNING, AJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (12): : 1047 - 1051
  • [30] Setting and Titrating Positive End-Expiratory Pressure
    Millington, Scott J.
    Cardinal, Pierre
    Brochard, Laurent
    CHEST, 2022, 161 (06) : 1566 - 1575